SLAB ACCESS REPAIR ENGINEERING.pdfMemorandum To: Roy Cali Date: May 17, 2016 Sympatico General Contracting LLC Address,: 7901168'" Ave NE Suite 105 From. Ryan Anderson Redmond. WA 98052 Project 190 Sunset 10811-2015-01 Structural Slab Recommendations Swenson Say Fag6t STeucn>Rar. ENSINEMNe 2124 Third Ave. Suite 100 Seattle, WA 98121 O 206.443.6212 934 Broadway. Suite 100 Tacoma, WA 98402 0 253.284.9470 Swenson Say Faget completed on-site observation of the structural slab at 190 Sunset on May 17. 2016. We observed the location of existing #3 reinforcing bar around the cut edges of slab. Where existing exposed reinforcing bar is located within the upper 14/2", no mechanical connection is required. Where existing bar Is located below 1-1/2", provide mechanical couplers per detail 9/S3.1. Coupled bar shall extend over the full width of the replaced slab sections or be lap spliced 24" with coupled bar extending from the opposite edge of slab. Provide a minimum of 1-1/2" concrete cover over new reinforcing bar and mechanical couplers. If you have any additional questions, please feel free to contact us. Best, Ryan AndersormR ply Project Manager 16