Sound Transit station.doc.pdfApril 9, 2008 TO: Brian Vanderburg FROM: Steve Fisher, City of Edmonds Public Works, 425-771-0235 RE: Plan review for proposed trash enclosure #2008-0257 KPFF Consulting Engineers The location for the proposed trash enclosure is appropriate, though the size needs to be adjusted. The 10' clear inside width as shown is the minimum required, but the depth needs to be increased to show clear 10' also, instead of the 8' shown. The gate support detail was not found. It is recommended that the gate sections be supported by finely -anchored posts at the end of each side wall as each section is required to be allowed to swing M 90 degrees at a minimum. The steel bollards shown on the site plan will need to increase their distance from each other in order to accommodate this swing. Drop pins or appropriate hardware is required to help secure gate sections in both the open and closed positions. The surface of the enclosure shall be a concrete slab at grade with the adjacent drive aisle.