Soundview Pl - 19018_SFR_BLD20080123 Jeffries 2.doc
City of Edmonds
TH
121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221
Website: www.ci.edmonds.wa.us
DEVELOPMENT SERVICES DEPARTMENT
Planning • Building • Engineering
Plan Review Corrections
Plan Check : Date:
# 2008-0123 March 5, 2008
Project Name/Address:
Jeffries/19018 Sound View Pl
Contact Person/Address/Fax:
Ben Jeffries 19018 Sound View Pl Edmonds, WA 98020
Reviewer: JoAnne ZulaufDivision:Engineering
During review of the subject submittal, it was found that the following information, corrections, or
clarifications would need to be addressed. Our handouts can be found online at the City of
Edmonds web site www.ci.edmonds.wa.us under City Government/Development
Services/Engineering Division.
The 4/29/08 resubmittal did not respond to any of the Corrections below. Please review and resubmit
information requested to continue review of your plans in a timely manner.
Thank you.
1.Provide a thorough breakdown of the existing and proposed impervious surface on the site plan, for
example;
Existing Impervious: Roof outline: xxxxx Year built: xxxx
Driveway: xxxx xxxx
Decks: xxxx xxxx
Total: xxxxx
Proposed Impervious: Roof outline: xxxx
Deck: xxx
Walkway: xxx
Total: xxx
Please consult City of Edmonds Storm Water Management handout #E72 for information regarding what
counts as impervious surface (i.e. pavers, gravel..).
2.
It is not permitted to build structures over a city storm drain line. In order to build in the location
indicated by the submitted plans, the storm drain pipe will need to be rerouted around the west side of the
DATE MAILED/FAXED 6/28/2017 PAGE ____
1
OF ___
3
new structure. It will be required that a new utility easement be granted the City of Edmonds to access
pipe for maintenance and repair. Please submit a site plan showing a proposed route with all relevant
Engineering will be unable to
invert and rim elevations, structures, ditch lines, etc. for review.
continue to review your plans without a proposed storm drain route.
3.Please provide a full drainage plan. Handout #E72 Storm Water Management will explain the detention
requirements for your property since you are adding over 2000sf of impervious surface after 1977.
Please note that if you are adding over 5000sf after 1977 then your drainage plans will need to be
Engineering will be unable to continue
stamped and signed by a Washington State licensed engineer.
to review your plans without a complete drainage plan.
4.
Please provide a grading plan showing existing and proposed contours. Please indicate “bottom of
Engineering will be unable to continue to review your plans without a
footing” on your site plan.
complete grading plan.
5.required
Please review handout #B57 Plot Plan for all information on your site plan. There is an example
checklistEngineering will be
as well as a to use to make sure you get everything needed on your plans.
unable to continue to review your plans without a complete site plan.
6.
Please show all utilities on site plan i.e. water line from water meter to house, gas line from property line
to house, side sewer from main to house, etc.
7.
If intention is to use existing side sewer lateral then it would need to be TV’d by Public Works to
determine if in good working condition. If intend to use any portion of the existing side sewer on private
property then it is the owner’s responsibility to TV that line to determine if in good condition for use.
8.Clearly label all areas on site plan. For example, it is difficult to tell if the area between the garage and
driveway is pavement/concrete area or something else.
9.If removing concrete area, walk, driveway, and stairs near existing house, please label “to be removed”.
10.Please add curb or brim of some kind on West and South sides of driveway area to prevent runoff.
11.Existing fence and gate shown on site plan are in the right of way. Please remove from right of way or
apply for Encroachment Permit. Handout E#26 explains requirements for Encroachment permit
application. This handout can be found on our website following the instructions above.
12.Please indicate that existing access from Water St. will be removed.
13.Erosion Control:
a)How do you plan to access site for construction? Will existing driveway be used? If
not, provide rock entrance per City of Edmonds standard detail E1.2 (All Standard
Details can be accessed at our website using the instructions above). If using rock
entrance please add detail to plans.
b)Show location of filter fence on site. Add filter fence detail to plans, must conform to
City of Edmonds standard detail E1.1.
c)All catch basins must be protected. Add catch basin protection detail to plans, must
conform to City of Edmonds standard detail E1.3.
DATE MAILED/FAXED 6/28/2017 PAGE ____
2
OF ___
3
Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator. Please
contact me at 425-771-0220 if you have specific questions regarding these plan corrections.
DATE MAILED/FAXED 6/28/2017 PAGE ____
3
OF ___
3