Special inspection field report.pdf--�``�" aZaI_1 & ASSOCIATES, INC.
GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING & INSPECTION
August 1, 2018
Mr. Nick Chou (E-Mail)
EDMONDS SCHOOL DISTRICT NO. 15
20420 681 Avenue W.
Lynnwood, WA 9836
RE: CONSTRUCTION TESTING AND INSPECTION
ESD Westgate Elementary Portable Classroom
9601 220th Street SW
Edmonds, Washington
Dear Mr. Chou,
KA No. 096-18353
Permit: BLD2018-0473
In accordance with your request and authorization, our firm performed construction testing and inspection
for the above -referenced project. The sampling and testing was performed by our inspectors and reports
are included.
If you have any questions, or if we can be of further assistance, please do not hesitate to contact our
office.
Respectfully submitted,
KRAZAN & ASSOCIATES, INC.
r-�
Ryman L. Mercer
Project Manager
Pacific Northwest Division
RLM/Ikj
cc: KPFF (E-MAIL)
4303 1981h Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837
With Officav Serving the Western United States
09618353 DFR.doc
Page 1 of 1
QKmzan&Associates, Inc. Field
Geotechnical Engineering • Environmental Engineering Report NO.: 09618353DFR7302018JK
Construction Testing and Inspection
DATE: 7/30/2018 Set Count: CONTRACTOR:
PROJECT #: 09618353 PERMIT #: BLD2018-0473
PROJECT: Westgate Elementary INSPECTOR: Jordan Kain
LOCATION: 9601 220a` St SW JURISDICTION: Edmonds
KAP.M.: Jeff Mercer WEATHER: Clear TEMP:85
Mechanical Anchors: Modular Classroom
Krazan & Associates representative arrived on -site for mechanical anchor inspection for the modular
classroom pod. Five anchors were applied to the four comers of the classroom foundation for a total of
20 anchors installed. Anchors were 5/8" wide 7" long Simpson Strong Bolt 2 anchors. Anchors were
installed 5" into the concrete foundation. Holes were brushed and blown prior to anchor installation.
Anchors were tightened using an automatic concussive ratchet. Below is a visual representation of the
anchor installation.
t N.
I 1i• � yr'. ' '=fir '����. �„
` a
v
ar
• r
r ti: •"�llyll .w
Reviewed
Asset Number(s):
To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and
regulatory requirements.
Superintendent/Representative: Technician:
ASTM Test #:
Offices Serving the Western United States
Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500
The information provided on this report is prep" for The exclusive use of the client This report may not be reproduced in any fomat without dsc written permission of the diem and Krazan & Associates. This report
in dIcates our iespectots observation and testing results based on site cond itions and contractor activities. Th s infcxn t:on is subject to review prior to final submittal By suing this report, one inspector does not aooept
responsibility for validity of results. The same information has beam provided by others on site.