This letter is a follow up to out conversations regarding the foundation for the Ricker Garage.
It is our understanding that you used the same detail to construct this project as was used on the
Abrahamson project (WCSE project no: W4448) as it has a similar layout.
Raw (Nor , _.. .-.
I!
01. saw
TOW • 1.
NMinur .
un 1
>{O.
R10hL Mo EI,Nat'em
The ricker project has 1 high corner, retaining 8 ft of soil. It then slopes down from there to 4
ft or less.
It is our understanding that the walls are formed and ready to be poured, however, the dimension
between steel reinforcing and face of wall is 2-3/4" rather than the specified 2" in the foundation
detail.
Soil Properties:
Active (pcf)
30
Passive (pcf)
300
Surcharge (psf)
35
Bearing (psf)
2000
Friction (f)
0.35
Density (pcf)
120
Project: W4521 Sheet No: 1 9/13/2018
WEST
COAST
STRUCTURAL
ENGINEERING. INC.
Concrete Properties:
Weight (pcf) 150
f'c (psi) 2500
Reinforcing Steel:
#4 & smaller (ksi) 40
#5 & larger (ksi) 60
Desc. Size Spacing (in)
V Bars 4 12
H Bars 4 12
9540 Semiahmoo Parkway (425) 347-8998
#137 wcse.net
Blaine, WA 98230
Retainina Wall Geometry
A (ft)
I B (in)
C (ft)
D (ft)
E (in)
F (in)
G (in)
H (ft)
0.33
8
0.33
1.33
0
8
0
8.00
Sliding:
SV (active) = 827 plf (slab) SV (active) = 413 plf
Resisting Forces
Description Weight (lb) Resistance (lb) Passive (lb)
Footing 133 47
Stemwall 800 280
Soil over Heel 320 112
Soil over Toe 0 0
Lug 0 0
Slab 300
Total 1253 439 975
SV (resisting) = 1414 plf
sliding safety factor = 1.71
Bending:
(lb-ft) factor factored moment (k-ft)
M (stemwall base) = 983 1.6 1.57
As = 0.196 (inz/ft) SRF (f) = 0.9
fy = 40000 (psi) d = 5 (B-3)
b= 12
M (allowed) = 34.2 (k-in) = 2.85 (k-ft)
Min. Reinforcing: As min ratio As (min).
fy V = 40000 V bars 0.196 0.002 0.192 ok
fy H = 40000 H bars 0.196 0.002 0.192 ok
Results: S.F.
Sliding: 1.71 ok
Strength: 1.81 ok
Project: W4521 Sheet No: 2 9/13/2018
WEST
COAST
S TRUCTURAL
9540 Semiahmoo Parkway (425) 347-8998
#137 wcse.net
Blaine, WA 98230
In this case, I looked at the concrete wall strength with a 3-inch spacing rather than a 2 inch.
The wall is still adequate in strength to handle the design load.
TRUSSES . II•
PER PLANS I!�
SIMPSON A35 AT c
EACH SIDE OFTRUSS
TO SILL FOR WALL BRACING
e
#4 HORIZONTAL
BARS @ 12" O.C.
OUTSIDE FACE
VERTICAL
BAR
UP TO 3" IS
OK FOR THIS PROJECT "INSIIEFIIE
Ij��/ 1LL PLAN VIEW #4 VERTICAL
BARS CD 12" O.C.
PLACE 2" CLR FROM
INSIDE FACE OF WALL
NOTE: ROOF FRAMING, SHEATHING.
ALL FOUNDATION WALLS & FLOOR
TO BE IN PLACE PRIOR TO BACKFIL
PLACEMENT.
#4 VERTICAL DOWELS , e
26" MATCH SPACING W/
VERTICAL WALL REINF
MIN. 42 BAR 0 LAP
e"
e
CONCRETE SLAB &
REINFORCING PER
FOUNDATION PLAN
• e
9-13-18
Travis McCandless PE, SE
West Coast Structural Engineering Inc.
P.T. 2x6 MUD SILL PLATE
W/1/2" 0 x 10" A.B. AT 18" O.C. & 12"
FROM END OF EACH MEMBER.
(2) #4 TOP
BARS
�I
�FINISHED GRADE
FREE -DRAINING
GRANULAR MATERIAL
12 WIDE MIN. TO WITHIN
12" OF FINISHED GRADE
WATERPROOF
MEMBRANE
RIGID INSULATION 4" PERFORATED
AS REOD AROUND FOOTING DRAIN
PERIMETER OF SURROUND W/ GRAVEL
LIVING SPACE
BRACED RETAINING WALL
SCALE: 3/4" = V-0"
Project: W4521 Sheet No: 3 9/13/2018