Special Inspection report.pdf& ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION November 9, 2018 Mr. Tony Collins (E-Mail) NORTH LIGHT CUSTOM BUILDERS LLC 914 164' Street SE, Suite B 12 Mill Creek, WA 98012 RE: CONSTRUCTION TESTING AND INSPECTION Stern SFR 17019 73' Place W Edmonds, Washington Dear Mr. Collins, KA No. 096-18509 Permit: BLD2018-946 In accordance with your request and authorization, our firm performed construction testing and inspection for the above -referenced project. The sampling and testing was performed by our inspectors and reports are included. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, KRAZAN & ASSOCIATES, INC. Christopher Congdon Project Manager Pacific Northwest Division RLMllkj 4303 1981h Street SW, Lynnwood, Washington 99036 - (425) 485-5519 • FAX (425) 485-6837 With' Offices Serving the Western United Stales 09616509 DFR dm QKrazan&Associ ate a, Inc. Geotechnical Engineering • Environmental Engineering Construction Testing and Inspection DATE: 11/6/2018 PROJECT M 09618509 PROJECT: Stem Family SFR LOCATION: 17019 73rd Place W. Edmonds Washing ton KA P.M.: Jeff Mercer STRUCTURAL STEEL WELDING INSPECTION REPORT NO.: 18509SSR11061&DL CONTRACTOR: North Light Custom Builders / Site Welding Service PERMIT #: BLD2015-946 INSPECTOR: David Lane JURISDICTION: City of Edmonds WEATHER: Clear TEMP: 48 ° ❑✓ FIELD ❑ SHOP WELDING ❑✓ VISUAL ❑ MA'rERIALID Item(s) Inspected: A) #4 ASTM A706 re -bar field welded connections to 2" O.D. driven micro piles for concrete footing. B) Epoxy anchor installations of #4 bar to (E) home foundation as per 4/S2.1. Location: A) 8 Locations - Rear of home. B) 6 Locations In (E) concrete foundation - rear of home. vvemaer quamR am f certincatlon verified for. Position: ❑ FLAT ❑ VERTICAL Process: 0 SMAW ❑ FCAW weld : __ ❑✓ FILLET_ ❑ C.P.-- Weld Size: ❑ 3/16- ❑ 1/4" Codes: a AWS ❑ AISC Jerrad Kolrud WABO ID #W05085 D1.1 & D1.4 ❑ ❑ ❑❑ ❑✓ Filler Metal: ❑❑ Other ❑ ❑ 0 ❑Other: ❑ Other: ❑ OVERHEAD SAW PI_u� 3/8" ASME HORIZONTAL GMAW P.P 5/1 fi' IBC E7018HR4 NOTES �J DISCREPANCIES 1 00 % COMPLETE Arrived onsite as per client —request. Confirmed welding personnel qualification and use of proper filler metal. Inspected the natcrials to be used for the field welding and adhesive anchoring. The re -bar onsite was not ASTM A706-weldable and here was not a sufficient amount of epoxy onsite to complete the anchor installations. Departed site while the contractor ;athered the proper materials. Re -arrived onsitc. Performed visual inspection of the re -bar attachment welds to the 2" micro Tiles. As per a phone conversation with the EOR, the bar was to be tack -welded only. The correct grade, size, number, and dimensions of re -bar was verified. Each micro pile received (3) 8x6" #4 re -bars, as -detailed. Each bar was welded with two 1" long vertical welds to the O.D. of the pile. Adhesive anchor installations were witnessed as per detail # 4 of S2.1. The :adhesive used was Simpson Set XP (expiration 8-24-19). Minimum embed depth of 6" was verified. Pre -cleaning and deposition of the epoxy was performed in accordance with the manufacturers printed installation instructions. V 0— sow, Q'- � ERP Y�!K%TA To the best of my knowledge, the above WAS performed In accordance with the approved plans, spAWflcadons and regulatory requlremenbL Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 •Tacoma (253) 939-2500 SVoaunl Stad Report m?HEpive 9!2612017 7Lofothmedoe pmid"tm Ole mpn L¢quetOrOp"oddwu�e°rO�et&m.iN„epon e„w�re �ryr°d.oaln.ry Cmui .11's.n Cc rri^runu�uLe N�/e <brc�ud KremAA.v�(VIH n, nytn ia;ioln°a bfpecim clnm�tir°ud btisl rrsJt,NW mein °.alYieru ad e"oneaa "NNvitloi lid, Om itaubJeet 1° rru.+ pnr w O>.1 ,✓reieul. uy tlpis, y, upon. ry �r,�d Mn ene � <eyi mvwuhiiy [x �it;ury o! mu:� t4 um wkrn•.,eim tu, hm (Rn�4M bjahn m ei1e.