Loading...
Special Inspection.pdf3 Lsa a,o r,, i,►y IV�� OTTO ROSENAU & ASSOCIATES INC. sec g 20�e Geotechnical Engineering, Construction Inspection & Materials Testing E1-�PMEN� ,r PROPRIETARY ANCHOR ADHESIVE INSPECTION REPORT C��N�R Job Number: 18-0269 Project: Margo Day Residence Address: 219 Skyline Drive, Edmonds Inspector: Travis Linn Report Number: 365450 Permit Number: (In progress) Client: Morris Originals, LLC Address: 3111 New Markey Street, Suite 105, Bellingham Date: 4/18/2018 Description/Location: ORA representative on site to inspect installation of epoxy all thread for foundation pad on west side of property. Intended Use: Steel column / foundation connection Building Code & Year: 2015 IBC ❑ Reinforcing Steel ® All Thread Bar/Dowel Size & Quantity: Anchor Size & Quantity: 1/4", (24) Type of Steel (ASTM): ❑ A-36 ❑ F-1554 ® A-307 Grade: ❑ 36 ® 50 ❑ 75 ❑ Other: Rebar Manufacturer: Rebar Grade: ❑ 40 ❑ 60 ❑ Other: Type of Bar: ❑ A-615 ❑ A-706 ❑ A-775 ❑ Other: Special Ductile Quality (SDQ): ❑ Yes ❑ No Anchor Length: 181, Hole Depth: 9" Required Embedment: 9" Hole Diameter: 7/8" Concrete Thickness: 24" (2), 12" (2) Concrete Strength: 2500+ Hole Orientation: ® Vertical Down ❑ Vertical Up ❑ Horizontal Base Material: ® Normal Weight Concrete ❑ Light Weight Concrete ❑ CMU ❑ Brick ❑ Composite Deck Hole Cleaning: ® Compressed Air ❑ Hand Pump ❑ Other: Compressed Air PSI: 100+ Brushed: ® Yes ❑ No Hole Condition: ❑ Dry ® Damp ❑ Water Saturated ❑ Submerged Drill Bit (ANSI B212.15): ® Yes ❑ No Approved Diamond Cored Hole: ❑ Yes ® No Adhesive Type: SET XP Expiration Date: 5/5/2019 ICC ESR #: 2508 Weather: Clear Ambient Temperature: 43°F Substrate Temperature: 417 Comments First (12) holes used SET XP, as stated above, on southwest pads. Last (12) holes used CIAGEL 7000-C, expiration date 8/14/2019, ESR #437, for holes on northwest side. Reference Standard(s) Used: Conforms X Does Not Conform _ Copies to: X Client X Engineer Others Owner Contractor Technical Responsibility: Architect X Building Dept. Isaac Ru , Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of 1 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1-888-OTTO-4-US - Fax (206) 723-2221 Form No.: ADM/N-86-02 (Rev. 05113) OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing CONSTRUCTION INSPECTION REPORT RECEIVED Report Number: 367913 MAY 2 9 2018 Project: Margo Day Residence Permit Number: (In progress) Address: 219 Skyline Drive, Edmonds Job Number: 18-0269 DEVELOPMENT SERVICES Client: Morris Originals. LLC Steel Decking Structural Steel Fabrication Structural Steel Erection Inspector and Date Chris Smith 4/11/2018 Copies to Client Address: Inspections Performed Other (specify): Soil bearing X Remarks 3111 New Market 5treet`F,%A ldl r=, beumgnam Other (specify): Contractor requested a site visit to inspect soil bear capacity. ORA representative soil probed 4 spread footings and one continuous footing at the south west corner of the property. A representative number of probe tests were taken throughout the referenced vicinity; based on penetration of 2" to 3" with sustainable resistance to advance into surface it is our recommendation that the top 1" to 2" of soil be removed before placement of concrete to reach competent soils that can support 1500 psf. Does Not Conform X Client X Engineer Others / � _C2� Owner Contractor Technical Responsibility: l� Architect X Building Dept. Isaac Ruoff, Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of 1 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1-888-OTTO-4-US - Fax (206) 723-2221 Form No.: ADMIN-63-05 (Rev 10/10) c OTTO ROSENAU & ASSOCIATES, INC. SPECIAL INSPECTION & MATERIALS TESTING OPEN ISSUE LOG Project: Margo Day Residence Permit: Job No.: 18-0269 Date Updated: 4/23/2018 Item Inspection No. Date Report I Inspector(s) No. Remarks Action Required (e.g. re -inspection, engineer follow up, etc.) Date Resolved 1 4/11/2018 367913 Chris Smith A representative number of probe tests were taken throughout the referenced vicinity; based on penetration of 2" to 3" with sustainable resistance to advance into surface it is our recommendation that the top 1" to 2" of soil be removed before placement of concrete to reach competent soils that can support 1500 psf. Reinspection RECEIVE,) MAY 2 9 2018 0EVEWPIVENT SERVICES Copies to: COUNTER X Client X Engineer Owner Contractor Technical Responsibility: Architect X Building Dept. Isaac Ruoff, Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 _ of 6747 M.L. King Way S., Seattle, Washington 98118 — Phone (206) 725-4600 or 1-888-OTTO-4-US — Fax (206) 723-2221