Loading...
Staff Report ADB-07-80.pdf CE ITY OF DMONDS th 121 5 Avenue North • Edmonds, WA 98020 Phone: 425.771.0220 • Fax: 425.771.0221 • Web: www.ci.edmonds.wa.us DSD: PD EVELOPMENT ERVICES EPARTMENTLANNING IVISION ADMINISTRATIVE DESIGN REVIEW FINDINGS, CONCLUSIONS, AND DECISION TO: Rick Klemm FROM: __________________________________ Mike Clugston, Planner DATE: February 1, 2008 Application for new four-unit condominium at 620/622 Glen Street in the ADB-2007-80 Multiple Residential (RM-1.5) zone. A. Property Owner Applicant Property OwnerApplicant Rick Klemm Rick Klemm PO Box 340 PO Box 340 Edmonds, WA 98020 Edmonds, WA 98020 B. Introduction Introduction The applicant is proposing to construct a new four-unit condominium building. Because of the project’s location and size, District-Based Design Review is performed pursuant to ECDC 20.12 and an Administrative Staff Decision is issued (ECDC 20.95). A “waiver” from critical area report requirements was issued under file number CRA-2007-0128. As proposed, the project does not trigger SEPA; however, SEPA may be required at the building permit stage. C. Edmonds Community Development Code (ECDC) Compliance Edmonds Community Development Code (ECDC) Compliance 1.ECDC 16.30 (Multiple Residential) Zone a.The improvements are proposed on property with a multiple residential zoning designation (RM- 1.5). Most properties in the immediate vicinity are also zoned and developed to the RM-1.5 requirements (see inset at right). b.The maximum lot coverage in multiple residential zones is 45% of the total lot area. Pursuant to ECDC 21.15.110, “coverage means the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting members or from a point two and one-half feet in from the outside edge of a cantilevered roof, whichever covers the greatest area.” The lot is 6,597 square feet. The applicant City of Edmonds Zoning Map, December 14, 2007 Page 1 of 6 Staff Report for ADB-2007-80 Klemm 4-Unit Condominium states that the building will cover 2,841 square feet or 43% of the lot. This will be confirmed at building permit review. c.Sample height calculations were provided on the elevations. It appears that the applicant has attempted to stay just at or under the maximum height (25 feet plus a potential 5 foot bonus for a 4/12 pitched roof), however this will be confirmed with the building permit. d.In the RM-1.5 zone, the minimum lot area per dwelling unit is 1,500 square feet. The subject parcel is 6,597 square feet yielding a maximum density of 4 dwelling units. This project proposes 4 dwelling units and thus is acceptable for the zone. e.The table below shows the required setbacks for structures in the RM-1.5 zone. Street Rear Side Side RM-1.5 Glen Street Alley (West) (East) Zone (North) (South) Required 15 feet 10 feet 10 feet 15 feet Setbacks Proposed 20 feet 10 feet 10 feet 22 feet Setbacks According to ECDC 16.30.040, eaves and chimneys may project into a required setback not more than 30 inches. The eaves and cantilevered roof over the entry on the west elevation appear to meet this criterion; all setback measurements will be confirmed during building permit review. 2.ECDC 17.50 (Parking) a.Multifamily parking requirements are based upon the number of dwelling units and the number of bedrooms per dwelling unit, pursuant to ECDC 17.50.020.A.1.b and the table below: Type of multiple Required parking spaces dwelling unit per dwelling unit Studio 1.2 1 bedroom 1.5 2 bedrooms 1.8 3 or more bedrooms 2.0 b.The floor plans (Attachment 5) indicate that each of the four units will have 2 bedrooms. The applicant has shown 8 enclosed spaces provided beneath the structure. It appears that the applicant will meet the minimum parking requirements; however, this will be confirmed through the building permit process as it is up to the Engineering Division to ensure that the parking spaces shown meet the minimum size requirements. 3.ECDC 20.13 (Landscaping Requirements) Pursuant to ECDC 20.13.020.E, “automatic irrigation is required for all ADB-approved landscaped areas for projects which have more than four dwelling units, 4,000 square feet of building area or more than 20 parking spaces.” Because the building will be in excess of 4,000 square feet (approximately 7,792 sf), automatic irrigation is required. A detailed final landscape plan and schedule will be reviewed with the building permit. More generally, the landscaping proposed is insufficient to soften the size and scale of the proposed building, particularly at the garage entrances. A planter and/or deciduous tree such Page 2 of 6 Staff Report for ADB-2007-80 Klemm 4-Unit Condominium as a vine maple (8’ - 10’) would be appropriate if positioned between the garage doors at both the north and south entrances. The areas of the proposed cherry trees at the four corners of the property should be augmented with other Type 2 landscaping. This would apply to the eastern extent of the site where only groundcover is currently shown. Finally, the Edmonds Street Tree Plan calls for Tilia cordata ‘Greenspire’ / Greenspire Linden on Glen Street. Two of these trees of appropriate size could be positioned at the corners of each of the driveways in order to further soften the appearance of the garages while still allowing adequate sight lines and access. A trellis or similar entrance feature placed where the western access walk meets the sidewalk at the northwest corner of the property would add additional interest. D. Criteria and Comprehensive Plan Compliance D. Criteria and Comprehensive Plan Compliance 1.Location. Since the parcel is designated “Multi-Family High Density” and within the “Downtown/Waterfront Activity Center,” the building is reviewed against the applicable Downtown Design Objectives found on pages 38 – 44 of the Comprehensive Plan. 2.Objectives for Site Design. “The development of parking lots, pedestrian walkways and landscaping features is an integral part of how a building interacts with its site and its surrounding environment. Good design and site planning improves access by pedestrians, bicycles and automobiles, minimizes potential negative impacts to adjacent development, reinforces the character and activities within a district City of Edmonds Comprehensive Plan Map, December 2006 and builds a more cohesive and coherent physical environment.” a.Vehicular Access and Parking. Parking is proposed to be enclosed beneath the structure. Two garages on the north side of the building access Glen Street and two on the south side access the alley. b.Lighting. Light fixtures are proposed adjacent to the garage entrances and at the western entrance. These fixtures should provide satisfactory lighting at those entrances. Several small bollard lights may be appropriate to increase illumination and safety along the access walk on the western side of the building. c.Signage. No signage was proposed in this application. All signs must meet the requirements found in ECDC 20.60. d.Site Utilities, Storage, Trash and Mechanical. No utility vaults, heating and cooling equipment, or other exterior utility equipment is proposed. A proposed trash enclosure will be screened from view by the proposed 48”cedar fence and will be accessed directly from the alley. 3.Design Objectives for Building Form and Facade. “Building height and modulation guidelines are essential to create diversity in building forms, minimize shadows cast by taller buildings upon the pedestrian areas and to ensure compliance with policies in the city’s Comprehensive Plan. Building façade guidelines ensure that the exterior of buildings, the portion of buildings that defines the character and visual appearance of a place , is of high quality and demonstrates the strong sense of place and integrity valued by the resident of the Page 3 of 6 Staff Report for ADB-2007-80 Klemm 4-Unit Condominium City of Edmonds. a.Height. According to the elevation drawings provided (Attachment 4), building height appears to be nearly to the 25’ height limit, including the use of a 4:12 roof to use the additional 5’ height exception available in RM zones. This is not out of character with the other multi-family structures in the immediate area. b.Massing. The building is a very simple series of layered rectangular boxes with a 4:12 roof. While there are a number of different materials and textures used to add to relief and interest to the building, it still feels boxy and massive. Additional wall and roof modulation would serve to break up the structure’s massive appearance. c.Roof Modulation. With only one chimney proposed, other roof modulation would be appropriate to break up what is otherwise a large monotonous roof mass. As proposed, the roof eves only extend 12” from the exterior walls. Extending the eves to the maximum of 30” (see C.1.e above) would provide additional protection from weather below and serve to de-emphasize the vertical feeling of the building. d.Wall Modulation. As mentioned above, the proposed building is fairly massive with wall modulation consisting of varied material applications. These applications separate the individual floors but they do not serve to reduce the feeling that the building is a large box. Placing the chimneys on the outside of the floor plan would allow that feature to vertically break up the east and west exteriors. e.Façade Requirements. The building’s main non-vehicular entry is on the west side. A cantilevered roof adds some interest and affords some weather protection for pedestrians. An entrance feature at the junction of the walkway and the sidewalk at the northwest corner of the parcel would tie the development to the existing streetscape. f.Window Variety and Articulation. Due of the orientation of the building on the lot, the largest windows are proposed for the north and south facades. Small decks are proposed on those facades as well. The windows on the east and west facades, while fairly plain, do provide nice balance to the facades but providing additional treatment around the windows would enhance the building’s aesthetic appeal. g.Building Façade Materials. Proposed materials include stone veneer around the garage entrances with horizontal siding along the remainder of the lower level. Vertical board and batten would define the first floor and cedar shingle the top floor. As proposed, the use of the materials creates busy facades. Eliminating the vertical siding on the first floor and using the same horizontal siding as that on the parking level would unify the building, create a less busy façade, and serve to further de-emphasize the boxy, vertical nature of the structure. The proposed belly bands will create the appearance of separation between the floors. h.Accents/Colors/Trim. Colors are shown on the color study (Attachment 6). The colors proposed are neutral, non-garish and compatible with colors used in surrounding development. More expressive colors are available, however, which could highlight the building or particular features of it. F.Technical Review F.Technical Review The Engineering Division and the Fire, Public Works, and Parks and Recreation Departments have reviewed this application. The Engineering Division noted that the applicant proposed total impervious area equal to 4966.5 square feet. A detention system worksheet was submitted for sizing of the detention system based on this figure. Impervious surface area and sizing of the storm detention system will be reviewed and verified by the Engineering Division at the time of Page 4 of 6 Staff Report for ADB-2007-80 Klemm 4-Unit Condominium building permit submittal. If the total impervious area exceeds 5000 square feet, the storm detention system will need to be designed and stamped by a licensed engineer. G.Decision G.Decision Based on the facts, conclusions, and attachments to this report, staff finds that the design review for this project (file number ADB-2007-80) is APPROVED with the following conditions: 1.Individual elements of this project are required to meet all applicable city codes, and it is the responsibility of the applicant to apply for and obtain all necessary permits. 2.The trash enclosure shall be constructed to meet the minimum dimensions required by code (see City of Edmonds handout #E37 for details) and will be reviewed and approved by the City Recycling Coordinator at the time of building permit. 3.An additional planting area (4’ by 4’ minimum) shall be positioned between the garage doors on the north and south facades. The area shall contain a 8’ – 10’ vine maple (or similar) with additional ground cover. 4.The areas surrounding the proposed cherry trees at the corners of the property shall be augmented with additional Type 2 landscaping. Type 2 landscaping shall also be included along the entire eastern boundary of the parcel where only hardy groundcover is currently shown. 5.Appropriately sized Tilia cordata “Greenspire’/ Greenspire Linden trees shall be placed in new planting areas (4’ by 4’ minimum) in the four exterior corners of both driveways. 6.A final landscaping plan must be submitted in accordance with ECDC 20.13.010. This plan must show the additional items included in these conditions of approval as well as the irrigation system and details. A landscaping bond estimate for all improvements shall be included. 7.The roof eves to shall be constructed to the maximum 30” that is allowed to project into a setback to de-emphasize the boxy nature of the structure. 8.The horizontal siding used on the lower level (or similar) shall also be applied to the first floor exterior in place of the proposed vertical board and batten. 9.A minimum of two small (approximately 8”) light bollards shall be placed along the access walk along the western portion of the development. 10.Impervious surface area and sizing of the storm detention system will be reviewed and verified by the Engineering Division at the time of building permit submittal. If the total impervious area exceeds 5000 square feet, the storm detention system will need to be designed and stamped by a licensed engineer. Staff finds that with these conditions, the proposal is consistent with the Comprehensive Plan and other adopted city policies, and the proposal satisfies the criteria and purposes of ECDC Chapter 20.10 – Design Review, ECDC 20.12 – District-Based Design Review, and ECDC Chapter 20.13 – Landscaping, as well as meeting the requirements of the zoning ordinance. Page 5 of 6 Staff Report for ADB-2007-80 Klemm 4-Unit Condominium H.Attachments H.Attachments 1.Land Use Application 2.Site Plan (A2) 3.Landscape Plan (A3) 4.Elevations (A4 and A5) 5.Floor Plans (A6 – A8) 6.Color Study I.Appeals and Expiration I.Appeals and Expiration The following is a summary of the deadlines and procedures for filing appeals and extensions. Any person wishing to file an appeal or extension should contact the Planning Division at 425.771.0220 for further procedural information. Appeals – Section 20.12.080 describes how appeals of administrative design review shall be made. ECDC 20.12.080.C: Design review decisions by staff under the provisions of ECDC 20.12.030 are only appealable to the extent that the applicable building permit or development approval is an appealable decision under the provisions of the ECDC. Design review by staff is not in itself an appealable decision. ECDC 20.12.080.D: Persons entitled to appeal are (1) the applicant; (2) anyone who has submitted a written document to the city of Edmonds concerning the application prior to or at the hearing identified in ECDC 20.12.020(B); or (3) anyone testifying on the application at the hearing identified in ECDC 20.12.020(B). Expiration – Section 20.12.90 describes the time limits for design review approval. ECDC 20.12.090.A: Unless the owner submits a fully completed building permit application necessary to bring about the approved alterations, or, if no building permit application is required, substantially commences the use allowed within 18 months from the date of approval, ADB or hearing examiner approval shall expire and be null and void, unless the owner files a fully completed application for an extension of time prior to the expiration date. Page 6 of 6