Loading...
StaffReport_ADB-07-60.pdf ARCHITECTURAL DESIGN BOARD STAFF REPORT October 17, 2007 Meeting PLANNING DIVISION ADVISORY REPORT AND RECOMMENDATIONS TO: The Architectural Design Board FROM: __________________________________ Gina Coccia,Planner DATE: October 10, 2007 ADB-2007-60 Application by Leah White of A.S.P.I., representing Troy Renneke (of TNT, th LLC) for the design review of a new duplex and triplex at 8629 238 Street SW in the Multiple Residential (RM-1.5) zone. A. PropertyOwner:Applicant: Property Owner:Applicant: Troy Renneke Leah White TNT, LLC A.S.P.I. 1136 Vista Place 4727-A Evergreen Way Edmonds WA 98020 Everett WA 98203 th B.: SiteLocation 8629 238 Street SW, located in the Multiple Residential (RM-1.5) zone Site Location (Attachment 2). C. Introduction: Introduction: The applicant is proposing to construct one duplex and one triplex (five dwelling units). The applicant shows that they are planning on clearing the entire site prior to construction (see Landscape Plan, Attachment 9). The following is staff’s analysis of the project. D. Overview: Overview: 1.Zoning: This parcel is located in the Multiple Residential (RM-1.5) zone (Attachment 2) and is subject to the requirements of ECDC 16.30 (Multiple Residential). 2.Environmental Review: Review under the State Environmental Policy Act (SEPA) is required if the proposed project will contain five or more dwelling units. The applicant turned in a project-specific Environmental (SEPA) Checklist and staff issued an Determination of Nonsignificance (DNS) on September 11, 2007 (Attachment 3). No comments or appeals were received. Both the City and the applicant have complied with SEPA requirements. Also, no critical areas were found to be on or adjacent to this property, therefore a “waiver” from critical areas report requirements was issued under file number CRA-1999-0240. 3.Issues: For this project, the Architectural Design Board reviews the design of the proposal and makes the final decision on whether the proposal is consistent with the design review criteria found in ECDC 20.11 (General Design Review) ECDC 20.13 (Landscaping), and with the Urban Design (General Objectives) found in the City’s Comprehensive Plan. Staff Report for ADB-2007-60 th TNT, LLC: Duplex & Triplex at 8629 238 Street SW E. EdmondsCommunityDevelopmentCodeCompliance: Edmonds Community Development Code Compliance The following is staff’s analysis on the project’s compliance with the Edmonds Community Development Code (ECDC). ECDC 16.30 (Multiple Residential) Zones 1. a. The improvements are proposed on property with a multiple residential zoning designation (RM-2.4). b. The maximum lot coverage in multiple residential zones is 45% of the total lot area. Pursuant to ECDC 21.15.110, “coverage means the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting members or from a point two and one-half feet in from the outside edge of a cantilevered roof, whichever covers the greatest area.” The building footprints shown appear to be approximately 5,025 square feet, which is about 46%; however, this will be confirmed through building permit review, which requires the applicant to provide a breakdown of lot coverage. c. Sample height calculations were provided on the elevations (Attachment 7). The roof shown is at a 6/12 pitch. It appears that the applicant has attempted to stay just at or under the maximum height (25 feet plus a potential 5 foot bonus for a 4/12 pitched roof), however this will be confirmed with the building permit. d. In the RM-1.5 zone, the minimum lot area per dwelling unit is 1,500 square feet. This parcel is approximately 10,836 square feet in area. This results in a maximum density of seven dwelling units. This project proposes five dwelling units and meets the underlying density for the zone. e. The table below shows the required setbacks for structures in the RM-1.5 zone. Street RearSideSide RM-1.5 th 238 Street SW (North)(East)(West) Zone (South) Required 15 feet 15 feet 10 feet 10 feet Setbacks Proposed 15 feet 19.5 feet 17.1 feet 10+ feet Setbacks f. ECDC 16.30.040.C.2 states “uncovered and unenclosed porches, steps, patios, and decks may project into a required setback not more than one-third of the required setback, or four feet, whichever is less; provided that they are no more than 30 inches above the ground level at any point.” The landscape plan (Attachment 9) clearly shows patios, but the site plan (Attachment 8) is not as clear. It appears that the project intends to meet the minimum setback requirements for the zone. Page 2 of 6 Staff Report for ADB-2007-60 th TNT, LLC: Duplex & Triplex at 8629 238 Street SW 2.ECDC 17.50 (Parking): a. Multifamily parking requirements are based upon the number of dwelling units and the number of bedrooms per dwelling unit, pursuant to ECDC 17.50.020.A.1.b and the table below: Type of multiple Required parking spaces dwelling unit per dwelling unit Studio1.2 1 bedroom 1.5 2 bedrooms 1.8 3 or more bedrooms 2.0 b. Preliminary floor plans indicate that there will be five 2-bedroom units, which yields nine parking spaces required. c. The number of parking spaces shown on the site plan is 5 in the garage and 5 stacked in front of the garages – however, these parking spaces need to be located entirely on the subject sight (no spill-over onto the adjacent access easement to the west). The Engineering Division will require that each parking space is at least 16½ feet x 8½ feet. d. Pursuant to ECDC 16.30.030.C, “No parking spaces may be located within the street setback.” It appears that the southern-most parking space meets this requirement. e. It appears that the applicant will meet the minimum parking requirements, however this will be confirmed through the building permit process as it is up to the Engineering Division to make sure that the parking spaces shown meet the minimum parking standards. 3.ECDC 20.11 (General Design Review): The proposed building does not conflict with the existing and planned character of the nearby area. The colors are not excessively brilliant, and the buildings are broken up, which makes them appear less massive. Exterior lighting is proposed at each front entrance and at the garage entrances, which do not face the street. Properties to the north, south, east, and west are all zoned Multiple Residential (RM-1.5). ECDC 20.11.030.B.1 states “Grading, vegetation removal and other changes to the site shall be minimized where natural beauty exists. Large cut and fill and impervious surfaces should be avoided.” Note:The ADB may want to ask the Applicant if there is any compelling reason why all of the existing vegetation needs to be removed. 4.ECDC 20.13 (Landscaping Requirements): Pursuant to ECDC 20.13.020.E, “automatic irrigation is required for all ADB-approved landscaped areas for projects which have more than four dwelling units, 4,000 square feet of building area or more than 20 parking spaces.” Automatic irrigation is required, and it will be reviewed with the building permit. The City’s Streetscape Plan does not indicate any required street trees for this site. The applicant proposes to remove all trees/vegetation from the site prior to construction. ECDC 20.13.020.C states “Existing vegetation that contributes to the attractiveness of the site should be retained. Existing significant trees and shrubbery (six-inch caliper or more) must be shown on the proposed landscape plan and saved and incorporated into the Page 3 of 6 Staff Report for ADB-2007-60 th TNT, LLC: Duplex & Triplex at 8629 238 Street SW landscape plan, if they are reasonably attractive and of good quality.” Staff argues that some of the existing perimeter landscaping may not need to be removed and should be retained if feasible. Note:The ADB may want to ask the Applicant if there is any way to retain any of the existing trees. F. ComprehensivePlanCompliance: F. Comprehensive Plan Compliance: The following is staff’s analysis on the project’s compliance with the City’s Comprehensive Plan. Location: 1. The existing Comprehensive Plan designation is “Edmonds Way Corridor.” This area is discussed in the Comprehensive Plan’s Land Use Element (page 59) and also in the Urban Design (General Objectives) section (pages 73-81), which is located in the Community Culture and Urban Design Element of the Comprehensive Plan. It is the Architectural Design Board’s responsibility for ensuring compliance of a project with the Comprehensive Plan. Staff has reviewed the pertinent sections of the Comprehensive Plan and documented their findings in the section below. 2.Goals for the Edmonds Way Corridor: F.3 Use design review to encourage the shared or joint use of driveways and access points by development onto SR-104 in order to support the movement of traffic in a safe and efficient manner. Site access should not be provided from residential streets unless there is no feasible alternative. The site plan shows that the applicant proposes to make use of an access easement along the western property line in order to gain access to the site. F.4. Use design review to ensure that development provides a transition to adjacent residential neighborhoods. For uses in transitional areas adjacent to single family neighborhoods, use design techniques such as modulation of facades, pitches roofs, stepped-down building heights, multiple buildings, and landscaping to provide designs compatible with single family development. Make use of natural topography to buffer incompatible development whenever possible. Instead of building one building, the applicant proposes breaking up the mass over two buildings. 3.Design Objectives for Site Design: “The development of parking lots, pedestrian walkways and landscaping features is an integral part of how a building acts with its site and its surrounding environment. Good design and site planning improves access by pedestrians, bicycles and automobiles, minimizes potential negative impacts to adjacent development, reinforces the character and activities within a district and builds a more cohesive physical environment.” In the following ways, this project appears to meet the design objectives for site design. Vehicular access is taken from the west along an adjacent vehicular access easement. The garages are less visible from the street, because access is taken from the western easement. Each unit will have individual garbage bins, so no dumpster is needed. 4.Design Objectives for Building Form: “Building height and modulation guidelines are essential to create diversity in building forms, minimize shadows cast by taller buildings upon the pedestrian areas and to ensure compliance with policies in the city’s Comprehensive Plan. Protecting views from public parks and building entries as well as street views to the mountains and Puget Sound are an important part of Edmonds character and urban form.” In the following ways, this project appears to meet the design objectives for building form. Page 4 of 6 Staff Report for ADB-2007-60 th TNT, LLC: Duplex & Triplex at 8629 238 Street SW There are no known views in the vicinity. The elevations appear consistent with the surrounding development. Note:The main entrances are sunken into the front elevations – the ADB may want to discuss ways to add prominence to the front entries. Design Objectives for Building Façade: 5.“Building Façade objectives ensure that the exterior of a building – the portion of a building that defines the character and visual appearance of a place – is of high quality and demonstrates the strong sense of place and integrity valued by the residents of the City of Edmonds.” In the following ways, this project appears to meet the design objectives for building façade. The elevations show cedar shingles and several neutral colors, including “chic” trim (I would refer to this color as putty), “new linen” for the body (I would refer to this color as a light putty), and “fair fieldstone” for the stonework (this color appears to be brown/grey). G. TechnicalReview: G. Technical Review: The Engineering Division and the Fire, Public Works, and Parks and Recreation Departments have reviewed this application. The Fire Marshall submitted a memo (Attachment 5). Three concerns were raised, primarily regarding the fire hydrants. The Applicant responded (Attachment 6) and revised the site plan to list the nearby hydrants. These will be further reviewed with the building permit. The Engineering Program Manager submitted a memo (Attachment 4). Engineering noted that a Traffic Impact Analysis was required, and the Applicant responded by turning in the TIA worksheet. This will be further reviewed with the building permit. Engineering also noted that the storm drainage system will need to be designed and stamped by a licensed engineer. This, too, will also be reviewed with the building permit application. H. PublicComment: H. Public Comment: To date, no public comments have been received. I. I.Recommendation: Recommendation: APPROVE Staff recommends that the Architectural Design Board the design of file number ADB-2007-60 with the following conditions: 1. Individual elements of this project are required to meet all applicable city codes, and it is the responsibility of the applicant to apply for and obtain all necessary permits. 2. With the building permit application, the applicant shall submit lot coverage calculations to show that the project remains under the required 45% coverage. 3. With the building permit application, the applicant shall show all patios and landings on the site plan and provide dimensions to the property lines showing that they meet the required setbacks. 4. With the building permit application, the applicant shall show all required off-street parking on site, providing parking space dimensions that are at least 16½ feet x 8½ feet (contact the Engineering Division for details). 5. The landscape plan shall be revised so that some significant vegetation is retained. The board finds that with these conditions, the proposal is consistent with the Comprehensive Plan and other adopted city policies, and the proposal satisfies the criteria and purposes of ECDC Chapter 20.11 – General Design Review, and ECDC Chapter 20.13 – Landscaping, and staff has found the proposal meets the requirements of the zoning ordinance. Page 5 of 6 Staff Report for ADB-2007-60 th TNT, LLC: Duplex & Triplex at 8629 238 Street SW J. Attachments: J.Attachments: 1. Land Use Application 2. Vicinity/Zoning Map 3. SEPA DNS 4. Memo from the Engineering Program Manager 5. Memo from the Fire Marshall 6. Letter from the Applicant 7. Elevations 8. Site Plan 9. Landscape Plan Page 6 of 6