Loading...
StevensPremeraParkingLot.pdf City of Edmonds PRE-APPLICATION COMMENTS BUILDING DIVISION DATE May 27, 2008 STAFF: Ann Bullis, Assistant Building Official RE: Project: Stevens Hospital/Premera Blue Cross Parking Lot 21700 Highway 99 A preliminary review was done with the pre-application materials provided and we have the following comments. Please feel free to contact me to discuss any code issues you may have during design. 1)Applicable codes in effect at the time of this meeting: a)2006 International Building Code (including Accessibility) with State Amendments 2)Please provide the total number of existing and proposed parking stalls on-site, so the number of accessible stalls per IBC 1106.1 may be calculated. Note accessible spaces must be located on the shortest accessible route of travel from adjacent parking to the accessible building entrance. 3)Accessible spaces shall be hard surfaced including the route of travel to the building entry. 4)Dimension the accessible parking stalls access aisles on the parking plan, and show the location of the required parking stalls signs (including sign detail). See attached example. ICC A117.1 502 5)Provide the slope within the accessible route of travel from accessible spaces to building entry. Provide details of ramps, curb ramps, etc. 6)Where the accessible path of travel crosses vehicular lanes, a cross walk must be provided. WAC 51-40-1106.6 7)Provide an exterior lighting budget worksheet. Building Division Pre-application Comments 1