STF20070010 5-14-07 MALUM LETTER.pdfM A H L a r c h i t e c t s 0; May 14, 2007 Ann Bullis, Assistant Building Official City of Edmonds 121 51h Avenue North - 2nd Floor Edmonds, Washington 98020 Project: Scriber Lake High School / Options Interim Site U M Subject: Alternative Design (2003 UBC Section 104.11) Limiting Occupant Load Dear Ms. Bullis: We request approval of alternative design as permitted by 2003 UBC Section 104.11. The proposed method will meet the intent of the provisions of this code and will provide a safe environment for the occupants. 1. The provision of IBC 2006 Section 1004.1.1. Exceptions, allow limiting occupant load less than that calculated by area. We request that the occupant load for four classrooms (H8, H10, H16, H19), with occupant loads of 51 (3) and 54 (1) be posted for a maximum occupancy of 49. This request would remove the requirement for two doors from these classrooms. The program for the Scriber Lake High School/Options Interim Site includes a total of 363 students and staff. The maximum anticipated classroom size is 22 students and two staff. See attached letter from Dawn Hart, Assistant Principal, Scriber Lake High School. 2. We also request that the occupant load for Staff Lounge H13 be posted for a maximum number of occupants of 49. The measured area is 1,4888 square feet and if calculated using 15 square feet per occupant, 99 occupants be used for exiting. There is a total staff of 57 for the Scriber Lake/Options programs. Thank you for your consideration in this matter. We are trying to provide a safe and comfortable environment for the students and staff. Please call with any questions. Sin r -LL eral (Bu c ).Reifert, AIA Principal GIR/kdb 20006606.00 mAY 17 2007 71 Cnlum6ia �� SUITE 400 S—W,' WA 98104 206 441.4]$] 20G 441.0478 {