STF20070014 City Approval letter dated 7-10-07.pdf4/,? C. 1S()v CITY OF EDMONDS GARYHAAKENSO MAYOR 121 5TH AVENUE NORTH • EDMOND5, WA 98020 • (425) 771-0220 • FAX (425) 771-0221 Website: www.d.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering July 10, 2007 Mr. Ralph Allen, AIA Grace Architects, PLLC 1927 Post Alley Seattle, Washington 98101 RE: Alternate Design Request/Old Milltown/Heavy Timber Columns Dear Mr. Allen, The City is in receipt of your request for Alternate Design (received by the City on July 2, 2007) for the Old Milltown building located at 201 5t' Avenue South, for acceptance of heavy timber columns as equivalent for Type VA construction. In reviewing the request it is noted that the size of the proposed columns (8"x8") is consistent with the provisions of the 2003 edition of the International Building Code Section 602.4.1 for Heavy Timber construction which states....'wood columns shall be sawn or glued laminated and shall not be less than 8 inches nominal, in any dimension where supporting floor loads and not less than 6 inches nominal in width and not less than 8 inches nominal in depth where supporting roof and ceiling loads only.' The request is hereby Approved with the following provisions: • All columns within the fire rated corridor shall be individually protected to one hour fire resistive construction, and • Columns within any concealed space shall be individually protected to one hour fire resistive construction for that portion that is concealed Sincerely, Jeannine L. Graf Building Official, C.B.O. Incorporated August 11, 1890 • Sister City - Hekinan, Japan