STF2007-0017 App letter rec'd 7-10-07.pdfTo: Edmonds Bldg. Dept. Re: Use of Studor vent For the Hadfield Residence 506 6th Ave. S. Permit #2006 0619 Date: 7/8/07 This is a formal request for the use of 4 studor vents in this residence. It is possible for the construction of this residence to use standard venting in all plumbing fixtures except the following. 1. The main kitchen sink, and the vegetable sink in the kitchen Island 2. The wet bar sink in the upstairs family room 3/ The kitchen sink in the first floor living area. It is not possible to maintain structural bearing integrity, or even reach an area to get to a roof vent in these locations. The use of these vents in this application is perfect for this situation. These vents are an approved system by code standards, and are used widely in all other jurisdictions that I have worked in. We have also tried a loop vent but cannot get the correct angles for such an application. If you need further information please ask, or if you would like to meet onsite at your convenience, I can meet your schedule. Enclosed is the spec. sheet for studor vents, and the coding approvals that it meets. If you have any questions I can be reached at 425-879-2315. Also I can arrange for you to converse with either the homeowner or the plumbing contractor in this matter. I appreciate your help in this matter, Sincerely, �J Z'10�4 Keith - KCL Enterprises 425-879-2315 Licensed General Contractor Lic.# KLENT232 DC RECEIVED J U L 10 20-01 BUILDIN DEPT. STUDOOMINI-VENT® Click Image for Submittal Sheet '"STUE L IrA/EMTIv*—_ MCM The unique design of the STUDORO MINI -VENTS provides plumbing vent prevent the loss of water seals in traps without the need for costly roof pe and vent piping. • Can be used as an individual, branch, circuit or stack vent • Fits 1 1/2" and 2" pipe sizes • Will vent up to 160 DFUs on a branch • Will vent up to 24 DFUs on stack • Expands architectural design limits • Reduces the number of fire -stopping applications • Exclusive vermin protection system • Limited lifetime warranty for replacement of defective valves For general planning and istallation, we recommend the use of the information contain on tF sheet for the Mini -Vent. The information is based on national standards, plumbing cod Hunter curve. Please contact us for special applications. h4://www.studor.com/mini-vent.htin 7/9/2007 f. STUDOK lr,vEA/riv� rEcrvniocaGr� Protective Cover (a) MINI-VyENTt' 278n�-�i 21a, (b) I .I4 10 Adaptor 1'W NPT (C) fits 1 % or 7 pipe sizes Materials: (a) Polystyrene (b)ABS (acrylonitrile butadiene styrene) valve with elastromeric membrane (c) ABS or PVC Adaptor Performance Standards: Specificati®n Sheet i MIINI-VENT® Manufacturer: Studor® Inc. Model: MINI -VENT' Item #: 20301 (PVC Connector) Connection Size: 1%"-2" 20300 (ABS Connector) General: An air admittance valve shall be acceptable as a vent termination for any individual vent, common vent, circuit vent, loop vent, island fixture vent, vent stack or stack vent that is provided to prevent siphonage of a fixture trap. An air admittance valve can be used as an alterrtafive to extending a vent through the roof (or sidewail) to the open atmosphere. Location: A. The MINI -VENT& should be located a minimum of 4" above the weir of the fixture trap for single fixture and branch venting and 6" above the flood level of the highest fixture for stack venting. B. Each valve should be installed in an accessible location. Installation: A. The valve should be connected to the piping in accordance with the manufacturer's installation instructions. B. The valve should be installed in the vertical, upright position after rough4n and pressure testing of the DWV system. C. A minimum of one vent shall extend to the open atmosphere for every building drainage system. D. The valve should not be installed as a vent terminal for any special (chemical) waste system or in supply and return air plenums. E. The valve may be installed on sewer ejectors, if installed according to engineer design and prior local code approval. F. For installation in areas with temperature ranges between -40°F and +150°F. Features: A. Screening on the inside and outside of the valve to protect the sealing membrane from insects and debris. B. Protective cover for the air intake and additional insulation against extreme temperatures. C. Ability to divert condensation away from the sealing membrane. D. Lifetime Warranty. • ASSE 1051 (revised 2002) single fixture and Branch type AAVs •.ASSE 1050 (revised 2002) Stade Type AAVs • NSF Standard 14 (Plastic Components) Code Approvals: •. International Plumbing Code (IPC) 2003 Edition • Southern Building Code Council International (SBCCI) 1994 Edition • Building Official Code Administration (BOCA) 1993 Edition International Residential Code (IRC) 2003 Edition Uniform Plumbing Code (UPC) Section 301.2 Alternative Materials and Methods 2003 Edition Listings; • ASSE Seal of Approval • National Evaluation Services (NES -592) • NSF International (NSF Standard 14) • NSF Intemational (ASSE Performance Standard 1051 and ASSE 1050) • IAMPO Classified Marking, file No. C-3803 • Warnock Mersey (ITS - Intertek Testing Services) Sizing Chart Horizontal Branch Size Max DFUs 1'/z' 3 2„ 6 3" 20 4 * 160 Stack Size Max DFUs 1'/z" 8 2" 24 i , STUDOR Inl/ENTive TECHAI01-OGY8 Protective Cover (a) MAXVVENT I�---47/s'=H 5Y4" (b) >� 3"—►I (c) 4" push -fit connector Materials: (a) Styrofoam cover (b) ABS (acrylonitrile butadiene styrene) valve with elastromeric membrane (c) Rubber connector Specification Sheet I MAXINENT® Manufacturer: Studor® Inc. Item ##: 20302 General: Model. MAXI-VENTO Connection Size: 3" or 4" An air admittance valve shall be acceptable as a vent termination for any individual vent, common vent, circuit vent, loop vent, island fixture vent, vent stack or stack vent that is provided to prevent siphonage of a fixture trap. An Air Admittance Valve can be used as an alternative to extending a vent through the roof (or sidewali) to the open atmosphere. Location: A. The MAXI -VENT° should be located a minimum of 4" above the weir of the fixture trap for single fixture and branch venting and 6" above the flood level of the highest fixture for stack venting. B_ Each valve should be installed in an accessible location. Installation: A. The valve should be connected to the piping in accordance with the manufacturer's installation instructions. B. The valve should be installed in the vertical, upright position after rough -in and pressure testing of the DWV system. C. A minimum of one vent shall extend to the open atmosphere for every building drainage system. D. The valve should not be installed as a vent terminal for any special(chemical) waste system or in supply and return air plenums. E. The valve may be installed on sewer ejectors, if installed according to engineer design and prior local code approval. F. For installation in areas with temperature ranges between -40'F and +150°F. Features: A. Screening on the inside and outside of the valve to protect the sealing membrane from insects and debris. B. Protective cover for the air intake and additional insulation against extreme temperatures_ C. Ability to divert condensation away from the sealing membrane. D. Lifetime Warranty, Performance Standards: • ASSE 1051 A & B (revised 2002) single fixture and Branch type AAVs • ASSE 1050 (revised 2002) Stack Type AAVs • NSF Standard 14 (Plastic Components) Code Approvals: • International Plumbing Code (IPC) 2003 Edition • Southern Building Code Council International (SBCCI) 1994 Edition • Building Official Code Administration (BOCA) 1993 Edition • International Residential Code (IRC) 2003 Edition • Uniform Plumbing Code (UPC) Section 301.2 Alternative Materials and Methods 2003 Edition Listings: • ASSE Seal of Approval • National Evaluation Services (NER-592) • NSF International (NSF Standard 14) • NSF International (ASSE Performance Standard 1051 and ASSE 1050) • IAMPO Classified Marking, file No. G-3803 • Warnock Hersey (ITS - Intertek Testing Services) Sizing Chart Horizontal Branch Size Max DFUs 3" 20 4" 160 Stack Size Max DFUs St 72 4" 500