Loading...
Storm line copmpaction test.pdf 741 Marine Drive, Bellingham, WA 98225www.geotest-inc.com 20611 67th Ave. NE. Unit A. Arlington, WA 98223 phone: (360) 733.7318 toll free: (888) 251.5276fax: (360) 733.7418 FIELD DENSITY/MOISTURE REPORT Nuclear Gauge * ASTM D6938 PROJECT:JOB #: Prestige Care14-0595 ADDRESS:REPORT #:FD015 2100 76th Avenue West, Edmonds, WAFD013 PERMIT #:DATE: BLD2014-04574/8/2015 4/13/2015 CLIENT:PAGE #: Prestige Care1 of 1 CONTRACTOR:INSPECTOR: Exxel PacificBen Fox Compaction Of: Backfill for Sewer Trench on 76th Ave. West Storm Field Data: Depth/DT/WetFieldDryCompaction TestLocation ElevBSDensityMoistureDensityLab%Pass/ # (ft)(in)(pcf)(%)(pcf)#AttainedRequiredFail 95 1Middle of Trench, 1’ E of Curb-0.5DT/12138.55.1131.81 96 95P 5.0 LabMax. DryOptimumRetained SampleSoil TypeSourceDensityMoistureOn #4Test #(pcf)(%)(%)Method 1-1989AWGS w/Silt & GravelMenzel Lake Pit138.78.047ASTM D1557 2-0.0None 3-0.0None Troxler 3440 / 67887743 / 2649 Gauge Make/Model/Serial#:M/D Standard Count: Comments: Elevations were referenced from curb height. GeoTest was on-site as requested to perform density testing of the backfill material used for the Sewer Storm Trench on 76th Ave W. The test attained the required compaction. COPIES: Exxel Pacific Carletti Architects, P.S. CG Engineering City of Edmonds Building DepartmentReviewed by This report shall not be reproduced except in full, without the written approval of GeoTest Services, Inc. The above test results relate only to the sample (or location) tested.