Loading...
Street crossings compaction.pdf 741 Marine Drive, Bellingham, WA 98225www.geotest-inc.com 20611 67th Ave. NE. Unit A. Arlington, WA 98223 phone: (360) 733.7318 toll free: (888) 251.5276fax: (360) 733.7418 FIELD DENSITY/MOISTURE REPORT Nuclear Gauge * ASTM D6938 PROJECT:JOB #: Prestige Care14-0595 ADDRESS:REPORT #: 2100 76th Avenue West, Edmonds, WAFD004 PERMIT #:DATE: 12/15/2014 CLIENT:PAGE #: Prestige Care1 of 1 CONTRACTOR:INSPECTOR: Exxel PacificBen Fox Compaction Of: Crushed Surfacing Top Course for Waterline Trench Crossing Field Data: Depth/DT/WetFieldDryCompaction TestLocation ElevBSDensityMoistureDensityLab%Pass/ # (ft)(in)(pcf)(%)(pcf)#AttainedRequiredFail 95 16" Waterline Trench, 15’ E of Curb-0.5DT/12136.25.1129.8195P 95 21" Water Service, 10’ E of Curb-0.5DT/12138.66.6130.1195P 95 34" Waterline Trench, 7’ E of Curb-1’DT/12140.27.4130.5195P LabMax. DryOptimumRetained SampleSoil TypeSourceDensityMoistureOn #4Test #(pcf)(%)(%)Method 1-5989CSTCSmokey Point Concrete137.26.236ASTM D1557 2-0.0None 3-0.0None Troxler 3440 / 604 / 2349 Gauge Make/Model/Serial#:M/D Standard Count: Comments: GeoTest was on-site as requested to perform density testing of the CSTC used for trench backfill for the three waterline trenches at the north end of the site on 76th Ave NE. All tests attained the required compaction. COPIES: Exxel Pacific Carletti Architects, P.S. CG Engineering City of Edmonds Building DepartmentReviewed by This report shall not be reproduced except in full, without the written approval of GeoTest Services, Inc. The above test results relate only to the sample (or location) tested.