Loading...
SummitCardiology1.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: September 27, 2007 REVISED TO: Dan Dierks, AIA Salmon Bay Design Group FAX: 206-783-6885 FROM: Ann Bullis, Assistant Building Official RE: Plan Check # 2007-0916 Project: Summit Cardiology – Tenant Improvement th Project Address: 7315 212 Street SW During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Provide written responses to each comment and where changes can be found on the plans. Please resubmit to Theresa Umbaugh, Permit Coordinator. 1.Note uses of space on floor plans and enlarged floor plans. Clearly distinguish the limits of individual suites from common areas, and clearly show the limits of the work done as part of this tenant improvement plan. It appears that changes are being made to the approved plans for Edmonds Family Medicine as well as Summit Cardiology, which will also require a tenant improvement permit. Please coordinate this with the Permit Coordinator, Theresa Umbaugh. 2.Provide floor areas and occupant loads for both tenant spaces. 3.Provide revised plumbing fixture calculations on the overall floor plan to justify reduced number of restrooms from what was approved under Permit 2006-1195. 4.Clarify on door schedule that pocket doors must have accessible hardware such as lever-style. 5.Show locations of emergency lighting and illuminated exit signs and specify type of power backup. 6.Clearly show that a portion of the reception counter meets accessibility requirements per ICC/ANSI A117.1 Section 904. 7.Dimension the required accessible maneuvering distances at doors 2310, 2334, 2336, 2332, 2338, 2340, 2300.