TacoTime3.pdf MessagePage 1 of 1 Bullis, Ann From: Bullis, Ann Sent: Monday, October 06, 2008 7:57 AM To: 'rickl@mlarch.com' Subject: Taco Time Building Division Comments Mr. Lentz, I have reviewed the resubmittal Taco Time and only one item remains that has still not been addressed: 2. Previous item 5 not addressed: A 1-hour exterior wall is required at the south side opening (between the columns) of the covered drive-through due to the close proximity to the property line (IBC 602 & 704.8). A 30” parapet with on-combustible face on the roof side is required for this exterior wall unless an exception can be used. Provide details and cross-reference where they apply to clearly show code compliance. This was included in the preapplication comments dated 1/17/07 and discussed at the meeting. Architectural and Structural plans must be revised. The plans show detail 7/A5 at the opening between the columns of the drive thru canopy, but this needs to be shown on the plans as 1-hour exterior wall with a parapet (unless a parapet exception is used). The opening created by the columns and beam is not permitted due to the fire separation distance. Floor plans, structural plans, elevation views and sections must also be revised to show this clearly. Please resubmit to Marie Harrison, Senior Permit Coordinator. If you have questions please contact me. Sincerely, Ann Bullis, CBO Building Official City of Edmonds 121 5th Ave N Edmonds, WA 98020 425-771-0220 10/6/2008