Loading...
TacoTimeAlt.pdf412 C. 18911 March 17, 2009 CITY OF EDMONDS GARY NAAKEN50N MAYOR 121 5TH AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 • FAX (425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT P€anning • Building • Engineering Michael Aleman Taco Time c/o Lynn Tac Inc. 1010 164` Street SW Lynnwood, WA 98037 RE: Request for Alternate Materials and Methods of Construction Equivalency Taco Time Restaurant, 23904 Highway 99, Edmonds, WA STF20090006, Plumbing Permit #2009-0138 Dear Mr. Aleman: The Office of the City Building Official is in receipt of the written request for Alternate Materials and Methods of Construction Equivalency dated March 16, 2009 per Section 301.2 of the 2006 Uniform Plumbing Code, made on your behalf by Alex Abossein, PE. The request is for use of circuit venting as part of an Engineered Plumbing System in accordance UPC Appendix L 7.0 at Taco Time Restaurant located at 23904 Highway 99, Edmonds, WA. After review of the information provided by your engineer, it is my determination as Building Official for the City of Edmonds that the circuit venting system is approved as shown on approved plumbing plan sheet P-2 of 3 dated 316109 as allowed under Section 301.2 of the Uniform Plumbing Code. Sincerely, Ann Bullis, CBO Building Official Incorporated August 11, 1890 Sister City - Hekinan, Japan ABosSEIN OT ,r. ENGINEERING, LLC Ef.ECTfLfCAI. MECHANICAL CIVIL FIRE PROTECTION LEER March 16, 2009 Ann Bullis, CBO Building Official City of Edmonds, WA Ref: Taco Time STF20090006 23904 Hwy 99 Edmonds, WA 98026 Request for Alternate Material and Methods of Construction Equivalency Dear Ms. Bullis We are requesting approval of Alternate Materials and Methods of Construction Equivalency per 2006 UPC 301.2 for the above named project. This request is specifically for Circuit Venting designed in accordance with UPC Appendix L 7.0 and is exclusive to this project for this site only and shall not set precedent for any other project. Due to the shallow site sewer available and the need to locate floor drains toward the center of aisles away from walls it is not possible to install conventional vents in compliance with UPC requirements. It is not possible to take vent connections off above the centerline of the floor drains without lowering the level of the trap and waste line. Lowering the trap and waste line from floor drains would push the sewer main below the level of the available site sewer invert elevation. The design of this system has been done with the full knowledge and approval of the building owner and this request is made on his behalf. me, if any additional questions or information is needed. Alex LeeD-AP AA: sh 2100 112th Avenue NE, Suite 201 • Bellevue, WA 98004 • PH: 425/462-9441 • FAX: 4251462-9451 • EMAIL: general@abossein.com R:1290201Correspondence\Ltr01-29020.doe