Loading...
Talbot_Rd-8008_Saffold_SFR_BLD20071261_2.pdf City of Edmonds TH 121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORKS DEPARTMENT Engineering Division Engineering Plan Review Comments Application :Date: # BLD20071216 December 23, 2008 Project Name/Address: Saffold SFR / 8008 – Talbot Rd Contact Person/Address, Fax or E-mail: Mike Johnson / mjhnsnwy@hotmail.com; Hank Saffold Reviewer: Edward Sibrel Division:Engineering During review of the civil drawings for the proposed project it was found that the following information, corrections, or clarifications will need to be addressed. Please resubmit 3 copies of the revised civil drawings and associated documents with a written response to each item to an Engineering Technician. Please contact me at 425-771-0220 or by e-mail at sibrel@ci.edmonds.wa.us if you have specific questions regarding these plan corrections. By direction of the City Engineer, the following engineering comments replace those written December 26, 2007: Review 1 – December 26, 2007 Revised Review – December 23, 2008 Engineering handouts and standard details are available at: http://www.ci.edmonds.wa.us/engr_dept.stm Grading Grading initially estimated at 490 cubic yards. Detention System 1. Given the proposed rim and invert elevation of the detention system, the detention pipe is too shallow. Top of pipe must be a minimum of 2' below a driveable area. 2. The control structure is located in the wrong CB. It should be in the downstream catch basin. 3. Include a profile drawing of the detention system with the drainage plan. 4. Drainage outfall shall not daylight at top of slope. Please design an alternate outfall method. 5. The detention system appears to be oversized, given the proposed impervious surface. Driveway 1. Specify on site plan the extent of driveway paving. Note that the driveway approach shall be paved from the street edge a minimum of 20 feet, or to the property line, whichever is greater. In either case, the pavement shall be asphalt to the property line. DATE E-MAILED December 23, 2008 PAGE(s) 1 of 2 City of Edmonds TH 121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORKS DEPARTMENT Engineering Division Engineering Plan Review Comments Side sewer Note where the proposed side sewer will be from the house to the main. Include all required cleanouts. If the existing sewer lateral from the main to property line is to be reused, contact Public Works at 425-771-0235 to ascertain the condition of the line. Water Service Line Note on the site plan where the water service line is to be located from meter to house. DATE E-MAILED December 23, 2008 PAGE(s) 2 of 2