Loading...
Thuesen_cabana-special_inspection.pdfAN( If (V 4 z! I/ i�,,Jv V l�A Af I' r "t? I'd w" If 0 SPECIAL INSPECTION AND TomSTENG AGREEMENT Proj ect, Permitfl-,: .. .. . . .. . ..... Prior to zvsmance of a permit, dais farm must be conipleted in its entiretP avid retm-ned to the City,foy, aplyrovaL The conxjfletcdfiqrm Ynxist have signatures of acknowlettg.menI 4v aliparties, DUTIES AIWRESPONSIBYLIIIES r Vc, C will perforni Special The Special Inspection firm of inspection for the following types of Work (separate forms naust be, submitted if more than one firm is to be employed): El Reinforced Concrete ID Spray applied Fireproofing LJ Bolting in Concrete 0 Smoke Control Systems 0 Prestressed Concrete ©Lateral Wood Ll Shoterete 0 Structural Observation * StrucLural Masonry 04Grading/soils ce, * StTuctural Steel/Welding 14 Other U High Strength Bolting 0 Other All individual inspectors to be employed on this project will be WABO certified for the type of work they are to inspect. If inspection is for work that is not covered by the WA130 categories, or the inspect tor is not WABO certified, a detailed resurne of tile inspector and firrn must be submitted. The resume must show that the inspector and the firm are qualified by education and experience to perform the work and testing required by the project design and specifications. The %vork shall be inspected for conformance with the plans and specifications approved by the City. Re,d,sions inspection and addenda sheets will not be used for inspection, unless they have been approved by :the City. h records shall include: A daily record to be maintained on site, itemizing the inspections performed. Any nonconforming work shallbe broll(ght to the immediate attention of the cont. -actor for resolution. A weekly report shall be submitted. to the City; detailing the inspections and testing perfonned, listing any nonconforming work and resolution of nonconf6rining items. A final report shall be submitted to the building department prior to the Certificate of Occupancy being issued. This report will indicate that inspection and Testing was corripleted in conformance with the approved plans, specifications and approved revisions or addenda, Any time discrepancies n-alst be detailed in the final report, 6. \ 131 j a I d i u t g, TQ u vv F o I d ur 201 MFor I ns I Sp C C m I i nsp ec. t o 01 f ol III . ( I o 0 1 W211201 0 11 E I 'ED4CEV �'UN 26 2012, [)[VO (WMEN I Contractor, The contractor shall provide the special inspector or agency adequate iio[Ification of work requiring inspec[ion. The City approved plan and specifications must be inade available, at ihejobsite for the use of the specual inspector and the City i-jispeeLor, The, contractor shall maintain all daily inspection reports, on site, for rc\,iow by all parties. considered to be in addition to the normal inspections perforined by the City The special inspection firlictI011s are consi' and the contractor iS,reSPODsible f6i contactirig the City to schedule regular inspections. No concrete shall be poured or other work, covered until approval is given b�y the City inspector, Ruilding Delmrtnieiftt: '],'he buildbig department shall review any revisions and addenda, The City inspector will monitor the special Inspection functions for compliance with the agreement and the approved plans, Tlae City inspector- shall be rcs])orisible for approving various stages of consiruclion to be covered and for work to proceed. P—L"Si"In —Professionals- Tbe architect and/or engineer will clearly indicate on the plans and specificatioris the specific types ofspecial inspection required, and shall include a schedule for inspection and testing. The architect and/or engineer will coordinate their revision and addenda process in such a way as to iiu.3ure that all required City approvals are obtained, prior to work shown on [lie, revisions being perforn-led in thefield. Owlxer The project owner, or the archilzol or engineer acting as the owners, agent, shall cniploy the special inspector Or agency. ENFORCEMENT A failure of the special inspector or firm to perform in keeping with the requirements of the T -MC, the approved PJHnS and this document, may void this agrecineut and the Building Official's approval of the special inspector. In such a case a new special inspector and/or finn would need to be proposed for approval, A faflul-c of the. design and/or construction parties to perform in accordance with this agreenIffit May result in a STOP WORY, notice being posted on the project until nonconforming items have been resolved. ACKNOWLE(DGMENTS I have read and agree to comply with the tennis and conditions of this agreement. Owner: _3 SignatUTe Date PY S Si �znature Date: contractol_ L= dau Signature Date: am Ll Arch./En-: A....... , , K- Signature Special Lisp. J"A',J Date, ACCEPTED FOR THE CITY Or, EDMONDS BUILDING DEPT. ,By Date: pc;cial inspection fnim.ducIOM/2010