Trike Stop FS & FA Fire Dept.doc MEMORANDUM Date:March 16, 2006 Development Services Lead Theresa Umbaugh To: From:Fire Marshal John J. Westfall 425.771.0213 th Subject:PC06-065 Trike Stop Auto Sprinkler 20919 76 Ave W th PC06-071 Trike Stop Fire Alarm 20919 76 Ave W Plans are currently on hold due to owner’s project re-evaluation. automatic sprinkler The following submittal has been evaluated under the 2003 International Codes. 1. Add general note: “I-4 occupancy requires IFC 903.3.1.1(NFPA 13) fire sprinkler system (IFC 903.2.5)” 2. Delete “Top Floor (13-R)” reference from plan title. 3. Add general note “Top floor separate dwelling has been approved for design calculation equivalent to 13R residential flow requirements.” 4. Hydraulic calculations for lower level daycare shows less than one psi difference between available (81.88 psi) and required pressure (80.99 psi) at water supply analysis. Increase this differential to no less than 10% by increasing water supply pipe size and/or replacing with lower flow sprinklers. 5. Increase hose stream allowance to 150 gpm (lower level daycare) to recognize typical pre-connected 1 ¾ “ firefighter hoseline. 6. Fire connection permit is required for the installation of the underground supply for your fire protection system. Underground design must be stamped by registered PE or a Level III (WA) fire sprinkler contractor AND the installer must also stamp the (dedicated FP supply) plans. The installer must be either Level III or Level “U” fire sprinkler contractor licensed by the State or a licensed plumber for a multi-purpose supply. Provide three copies of plans showing all valves, backflow devices, vault location, post indicating valve, fire department connection and piping to include size and material, hydraulic calculations, thrust blocking with calculations, pipe bury depth and any and all other materials used and their fire protection listings. RCW 18.160.070 / RCW 18.27.110 City of Edmonds Fire Marshal   7. Add a pendant in stairway or clarify sufficient coverage as designed. fire alarm The following submittal has been evaluated under the 2003 International Codes. 8. Move FACP to lower daycare level and next to sprinkler riser. The upper level will be a dwelling unit separated from the daycare use. 9. Move pull station and keypad to main daycare entrance. 10. You may delete rate of rise detectors in lower and upper levels due to fire sprinkler protection. 11. You may delete automatic smoke detectors from top floor dwelling and install hardwired smoke alarms interconnected with battery backup where required. 12. Maintain waterflow and supervisory switching duty, notification throughout useable spaces and remote monitoring. Cc: Reid, Cascade Alarm (253) 630-4851 Assistant Building Official Ann Bullis