ValhalaMixedUseFDN2.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: June 19, 2008 TO: Lesley Brown lesleyb@adshapiro.com FROM: Ann Bullis, Assistant Building Official RE: Plan Check # 2007-1219 Project: Valhalla Mixed Use – Foundation only Project Address: 23020 Edmonds Way A review of the plans for the foundation and PT deck has been done and we have the following remaining comment. The remaining architectural and structural review will be done under the permit application for the main building. Please revise plans accordingly and resubmit to Marie Harrison, Permit Coordinator. 1.Parking garage exhaust outlet locations must meet IMC/WAC 501.2.1 #2 (10 feet from property lines; 3 feet from exterior walls and roofs; 10 feet from operable building openings, 10 feet above adjoining grade). The garage exhaust for level P1 does not meet this requirement and affects the foundation wall/PT deck.