Loading...
Wall revision-Eng report.pdf1 L i'1 ftg 7/26/18 UPSTATE engineering PO BOX. 952 LYNNWOOD, WA 98066 T. (206) 260-4715 F. (206) 834-6261 SERVICES@UPST8.COM July 26, 2018 John Murphy Murphy Building Co. 6203 202nd Street SW Lynnwood, WA 98036 Re: Upstate Job#0719 O'Neal Residence Foundation Wall Revision To Whom It May Concern: A representative from this office inspected the formwork for the foundation wall along the entry area and around the corner to the south. Site conditions required that the wall within this area be 12'3" tall from the top of footing to the top of wall. A slab will be installed approximately ZY above the toe side of the footing. The attached calculations show that the wall is structurally adequate to resist the required loads with no revisions to the dimensions nor reinforcement. Attached are revised calculations and revised foundation detail. Should there be any questions or comments please contact our office. Sincerely, rA� Andrew Gahan, PE 0419 O'NPAL 0: 1Z6VS5bD CAt4-FSLP-V1--lF D rOUNDA-FZON VIALL DgsZgN FOtz AXEA l;*Gur-I?SNq 1Z3" HEZ4-HT ;] FRAMING PER PLAN LOCATION BY OTHERS COMPACTED FRONT FILL 1: 2 (V: H) MAX SLOPE EXTEND 6'-0" MIN or 4" SLAB W/ 6X6 W1.4 X W1.4 WWF OR #3 ® 12"o/c E.W. ` CONCRETE FOOTING w/ #4 CONT @ 10"o/c GENERAL NOTES: IBC 2015 EDITION 35 PCF EQUIVALENT FLUID PRESSURE 3000 PSF SOIL BEARING CAPACITY 50 PSF SURCHARGE (TOE SIDE) 8H LATERAL SEISMIC LOAD 5 1/2 SACK CEMENT PER CUBIC YARD, 2500 PSI MINIMUM COMPRESSIVE STRENGTH, MAXIMUM 6 GALLONS WATER PER SACK GRADE 60 STEEL FOR #5 & LARGER GRADE 40 STEEL FOR #4 & SMALLER BACKFTL L WITH PC_OUROUS MATERIAL; PROVIDE TEMPORARY BRACINGS AS REQUIRED UNTIL SLAB IS CONSTRUCTED AND CURED WALL PER PLAN OR SW SCH (2)— #4 CONT 0 TOP 6"MIN HORIZONTAL BARS: PER SCHEDULE VERTICAL BARS: PER SCHEDULE FTG DOWELS W/ STD HOOK INTO FTG: MAX HEIGHT PER 2"CLR SAME AS VERT BAR OF BACKFILL: SCHEDULE SPACING PER SCHEDULE LAP: 30"MIN • YCLR I=LG WALL HEEL TOE — TOE BARS: PER SCHEDULE - 2" TOP CLR 4" 0 FTG DRAIN IN GRAVEL POCKET BEARING SOIL FTG THCK f REINFORCEMENT AND FOOTING SCHEDULE MAX HEIGHT OF BACKFILL VERTICAL REINFORCEMENT HORIZONTAL REINFORCEMENT TOE WIDTH WALL WIDTH HEEL WIDTH FOOTING THICKNESS TOE BARS FRONT FILL REQ'D 6'-0" #5 @ 16" O.C. #5 @16" O.C. 2'-0" 8" 4" 12" #5 @ 12" OC 12" OR SLAB 8'-0" #5 @ 12" O.C. #5 @16" O.C. 2'-9" 8" 10" 12" #5 @ 12" OC 12" OR SLAB. LA #5 @16" O.C. 2'-9" 8" 1'-4" 12" #5 @ 12" OC a,eoVETOE TYPICAL CANTILEVERED FOUNDATION WALL NTS PO BOX 952 Title 12'-3".SLAB @ 27' Page: 1 LYNNWOOD, WA 98046 Job # : 0934 Dsgnr: amg Date: 26 JUL 2018 UPSTATE (206) 280-4715 Description. ngineering SERVICES@UPST8.COM O'NEAL This Wall in File: C:\Users\Andy\Documents\UPST8 MAIN\2017 (0695-0866 Orange)\0719 Nash - O'Neal Res RetainPro (c) 7987-2016, Build 71.76.07.15 KW- License : 06060767 Restrained Retaining Wall Code: IBC 2015,AC1 318-14,AC1 530-13 esneg License To .Upstate Engineering Criteria , Soil Data ' Retained Height = 11.75 ft Allow Soil Bearing = 3,000.0 psf Wall height above soil = 0.50ft Equivalent Fluid Pressure Method Total Wall Height = 12.25ft At -rest Heel Pressure = 35.0 psf/ft Top Support Height = 2.25 ft Passive Pressure = 300.0 psf/ft Soil Density = 135.00 pcf Slope Behind Wal = 0.00 FootingIlSoil Frictior = 0.500 Height of Soil over Toe = 27.00 in Soil height to ignore for passive pressure = 1200 in Surcharge Loads Surcharge Over Heel = 0.0 psf -Used To Resist Sliding & Overturning Surcharge Over Toe = 50.0 psf Used for Sliding & Overturning Axial Load Applied to Stem ' Axial Dead Load = 245.0 Ibs Axial Live Load = 345.0 Ibs Axial Load Eccentricity = 0.0 in Uniform Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0 00 ft ...Height to Bottorr = 0.00 ft Load Type = Wind (W) (Strengtn Level) Wind on Exposed Stem = 0.0 psf Thumbnail Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil = 0 0 ft at Back of Wall Poisson's Ratio = 0.300 Earth Pressure Seismic Load ' Kh Soil Density Multiplier = 0.200 g Added seismic per unit area = 0.0 psf Stem Weight Seismic Load ' Fp / Wp Weight Multiplier = 0 000 g Added seismic per unit area = 0.0 psf Design Summary Concrete Stem Construction Total Bearing Load = 5,675 Ibs Thickness = 8.00 in Fy = 60,000 psi ...resultant ecc. = 8.30 in Wall Weight = 100.0 psf fc = 3,000 psi Stem is FREE to rotate at top of footing Soil Pressure @ Toe = 1,195 psf OK Soil Pressure @ Heel = 1,195 psf OK Allowable = 3,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 184 psf ACI Factored @ Heel = 2,741 psf Footing Shear @ Toe = 1.2 psi OK Footing Shear @ Heel = 3.0 psi OK Allowable = 75 0 psi Reaction at Top = 4,201.8 Ibs Reaction at Bottom = 2,255.8 Ibs Sliding Calcs Lateral Sliding Force = 2,255.8 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Load Factors Building Code IBC 2015,AC1 Dead Load 1.200 Live Load 1.600 Earth, H 1 600 Wind, W 1 000 Seismic, E 1 000 Mmax Between @ Top Support Top & Base @ Base of Wall Stem OK Stem OK Stem OK Design Height Above Ftg = 2 25 ft 0.00 ft 0 00 ft Rebar Size = # 5 # 5 # 5 Rebar Spacing = 8.00 in 8.00 in 8 00 in Rebar Placed at = Edge Center Center Rebar Depth 'd' = 5.50 in 4 00 in 4.00 in Design Data fb/FB + fa/Fa = 0 758 0.000 0.000 Mu... Actual = 8,002.2 ft-# 0 0 ft-# 0.0 ft-# Mn " Phi. ...Allowable = 10,552.0 ft-# 7,413 2 ft-# 7,413 2 ft-# Shear Force @ this height = 4,202.3 Ibs 2,863.5lbs Shear.. Actual = 63.67 psi 59.66 psi Shear ...Allowable = 82.16 psi 82 16 psi Other Acceptable Sizes & Spacings: Toe: None Spec'd -or- Not req'd: Mu < phi'Slambda"sgrt(fc)'Sm Heel: None Spec'd -or- Not req'd: Mu < phi"5lambda"sgrt(fc)'Sm Key: No key defined -or- No key defined PO BOX 952 Title 12'-3"•SLAB @ 2'3" Page : 2 LYNNWOOD, WA 98046 Job # : 0934 Dsgnr: amg Date: 26 JUL 2018 UPSTATE A E (206) 280-4715 Description . SERVICES@UPST8.COM O'NEAL This Wall in File: C:\Users\Andy\Documents\UPST8 MAIN\2017 License: KW06060767' "' "'" Restrained Retaining Wall Code: IBC 2015,AC1 318-14,ACI 530-13 Concrete Stem Rebar Area Details Top Support Vertical Reinforcing As (based on applied moment) 0 3432 in2/ft (4/3) " As: 0.4576 in2/ft 200bd/fy : 200(12)(5.5)/60000 : 0.22 in2/ft 0.0018bh : 0.0018(12)(8) : 0.1728 in2/ft Required Area 0.3432 in2/ft Provided Area 0.465 in2/ft Maximum Area: 0 8941 in2/ft Mmax Between Ends Vertical Reinforcing As (based on applied moment) 0 in2/ft (4/3) " As : 0 in2/ft 200bd/fy : 200(12)(4)/60000 : 0.16 in2/ft 0 0018bh : 0.0018(12)(8) : 0.1728 in2/ft Required Area 0.1728 in2/ft Provided Area : 0 465 in2/ft Maximum Area : 0.6503 in2/ft Base Support Vertical Reinforcing As (based on applied moment) 0 in2/ft (4/3) ` As : 0 in2/ft 200bd/fy : 200(12)(4)/60000 : 0.16 in2/ft 0.0018bh : 0.0018(12)(8) : 0.1728 in2/ft Required Area 0.1728 in2/ft Provided Area 0.465 in2/ft Maximum Area. 0 6503 in2/ft Footing Strengths & Dimensions Toe Width = 2.7.5 ft Heel Width = 2.00 Total Footing Widtt = 475 Footing Thickness = 13.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft fc = 2,500 psi Fy = 40,000 psi Footing Concrete Density = 150.00 pcf Min As % = 0.0018 Cover @ Top = 2.00 in @ Btm.= 3.00 in Horizontal Reinforcing Min Stem T&S Reinf Area 0 432 in2 Min Stem T&S Reinf Area per ft of stem Height: 0.192 in2/ft Horizontal Reinforcing Options : One layer of: Two layers of: #4@ 12.50 in #4@ 25.00 in #5@ 19.38 in #5@ 38 75 in #6@ 27.50 in #6@ 55.00 in Horizontal Reinforcing Min Stem T&S Reinf Area 0.432 in2 Min Stem T&S Reinf Area per ft of stem Height: 0 192 in2/ft Horizontal Reinforcing Options : One layer of: Two layers of: #4@ 12.50 in #4@ 25.00 in #5@ 19.38 in #5@ 38.75 in #6@ 27.50 in #6@ 55.00 in Horizontal Reinforcing Min Stem T&S Reinf Area 0 000 in2 Min Stem T&S Reinf Area per ft of stem Height: 0.000 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of: #4@ 0.00 in #4@ 0.00 in #5@ 0.00 in #5@ 0 00 in #6@ 0 00 in #6@ 0.00 in Footing Design Results - 100 eel Factored Pressure = 184 2,741 psf Mu': Upward = 2,563 2,676 ft-# Mu': Downward = 2,418 1,865 ft-# Mu: Design = 145 -810 ft-# Actual 1-Way Shear = 1.24 3 00 psi Allow 1-Way Shear = 75.00 75 00 psi Min footing T&S reinf Area 1.33 in2 Min footing T&S reinf Area per foot 0.28 in2 ift If one layer of horizontal bars: If two layers of horizontal bars #4@ 8.55 in #4@ 17.09 in #5@ 13.25 in #5@ 26.50 in #6@ 18 80 in #6@ 37.61 in PO BOX 952 Title 12'-3".SLAB @ 2'3" Page: 3 LYNNWOOD, WA 98046 Job # : 0934 Dsgnr: amg Date: 26 JUL 2018 UPSTATE (206) 280-4715 Description . engroeenng O'NEAL SERVICES@UPST8.COM This Wall in File: C:\Users\Andy\Documents\UPST8 MAIN\2017 (0695-0866 Orange)\0719 Nash - O'Neal Res RetainPro (c) 1987-2016, Build 11.16.07.15 License: KW-06060767 Restrained Retaining Wall Code: IBC 2015,AC1 318-14,AC1 530-13 License To : Upstate Engineering Summary of Forces on Footing : Slab RESISTS sliding, stem is PINNED at footing Forces acting on footing soil pressure (taking moments about front of footing to find eccentricity) Surcharge Over Heel = Ibs ft ft-# Axial Dead Load on Stem = 590 Olbs 3.08 ft 1,819.2ft-# Soil Over Toe = 835 3lbs 1.38 ft 1,148.6ft-# Adjacent Footing Load = Ibs ft ft-# Surcharge Over Toe = 137.5lbs 1 38 ft 189 1 ft-# Stem Weight = 1,225.Olbs 3.08 ft 3,777 1ft-# Soil Over Heel = 2,115 Olbs 4.08 ft 8,636.3ft-# Footing Weight = 771.9lbs 2.38 ft 1,833.2ft-# Total Vertical Force = 5,674 7lbs Moment = 17,403 3ft-# Net Mom. at Stem/Ftg Interface = -3,925.9 ft-# Allow. Mom. @ Stem/Ftg Interface = 4,633.3 ft-# Allow. Mom. Exceeds Applied Mom.? Yes Therefore Uniform Soil Pressure = 1,194.7 psf Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. PO BOX 952 Title 12'-3"SLAB @ 2'3" Page: 4 LYNNWOOD, WA 98046 Job # .0934 Dsgnr: amg Date: 26 JUL 2018 S'I n'TE (206) 280.4715 Description.... SERVICES@UPST8.COM O'NEAL This Wall in File: C:\Users\Andy\Documents\UPST8 MAIN\2017 (0695-0866 Orange)\0719 Nash - O'Neal Res RetalnPro (c) 1987-2016, Build 11.16.07.15 License: KW-06060767 Restrained Retaining Wall Code: IBC 2015,AC1 318-14,ACI 530-13 License To : Upstate Engineering Rebar Lap & Embedment Lengths Information Stem Design Segment Near Top Support Stem Design Height: 2 25 ft above top of footing Lap Splice length for #5 bar specified in this stem design segment = 21 36 in Lap Splice length for #5 bar extending up into this stem design segment from below = 21.36 in Development length for #5 bar specified in this stem design segment = 16.43 in Development length for #5 bar extending up into this stem design segment from below = 16.43 in Stem Design Segment at Mmax Between Ends Stem Design Height: 0.00 ft above top of footing Lap Splice length for #5 bar extending down into this stem design segment from above = 21.36 in Lap Splice length for #5 bar specified in this stem design segment = 21.36 in Lap Splice length for #5 bar extending up into this stem design segment from below = 21.36 in Development length for #5 bar extending down into this stem design segment from above = 16.43 in Development length for #5 bar specified in this stem design segment = 16.43 in Development length for #5 bar extending up into this stem design segment from below = 16.43 in Stem Design Segment at Base Support Stem Design Height: 0 00 ft above top of footing Lap Splice length for #5 bar extending down into this stem design segment from above = 21.36 in Lap Splice length for #5 bar specified in this stem design segment = 21 36 in Development length for #5 bar extending down into this stem design segment from above = 16 43 in Development length for #5 bar specified in this stem design segment = 16.43 in Hooked embedment length into footing for #5 bar specified in this stem design segment = 6.00 in As Provided = 0.4650 in2/ft As Required = 0.1728 in2/ft PO BOX 952 Title 12'-3"•SLAB @ 73" Page : 5 LYNNWOOD, WA 98046 Job # : 0934 Dsgnr: amg Date: 26 JUL 2018 UPSTATE (206) 280-4715 Description.... cn9inccring SERVICES@UPST8.COM O'NEAL This Wall in File: C:\Users\Andy\Documents\UPST8 MAIN\2017 (0695-0866 Orange)\0719 Nash - O'Neal Res RetainPro (c) 1987-2016, Build 11.16.07.15 License: KW-060667 Restrained Retaining Wall Code: IBC 2015,AC1 318-14,ACI 530-13 License To :Upst07ate Engineering Z-9, Z-0 PO BOX 952 Title 12'-3";SLAB @ 2'3" Page : 6 LYNNWOOD, WA 98046 Job # : 0934 Dsgnr: amg Date: 26 JUL 2018 UPS I ATE1 (206) 280-4715 Description.. SERVICES@UPST8.COM O'NEAL This Wall in File: C:\Users�Andy\DocurnerltskUPST8 MAIN\2017 (0695-0866 Orange)\0719 Nash - O'Neal Res RetainPro (c) 1987.2016, Build 11.16.07.15 License : KW•0667 Restrained Retaining Wall Code: IBC 2015,AC1 318-14,ACI 530-13 License To :U06pst07ate Engineering 64IS cIN CL r.. rn PO BOX 952 Title 12'-3"SLAB @ 213" Page : 7 LYNNWOOD, WA 98046 Job # : 0934 Dsgnr: amg Date: 26 JUL 2018 UPSTATE (206) 280-4715 Description.... engineering SERVICES@UPST8.COM O'NEAL This Wall in File: C:\Users\Andy\Documents\UPST8 MAIN\2017 (0695-0866 Orange)\0719 Nash - O'Neal Res RetainPro (c) 1987-2016, Build 11.16.07.15 License: KW-060667 Restrained Retaining Wall Code: IBC 2015,AC1 318-14,ACI 530-13 License To :Upst07ate Engineering Concrete EMasonry Designer to determine bar cutoff locations 800.0lbs 2.400.0lbs 4,000.0lbs 5,600.0lbs 7,200.0lbs 0.0lbs 1 1.600.0lbs 1 3.200.0lbs 1 4.800.0lbs 1 6.400.0lbs I ft 12.25 ........... .I . ............ .I PO BOX 952 LYNNWOOD, WA 98046 UPSTATE rn9 ATEncering (206) 280-4715 SERVICES@UPST8.COM Title 12'-3";SLAB @ 2'3" Page : 8 Job # : 0934 Dsgnr: amg Date: 26 JUL 2018 Description. O'NEAL This Wall in File: C:\UsersWndy\Documents\UPST8 MAIN\2017 (0695-0866 Orange)\0719 Nash - O'Neal Res RetainPro (c) 1987-2016, Build 11.16.07.15 License: KW-..O 767 Restrained Retaining Wall Code: IBC 2015,AC1 318-14,AC1 530-13 License To :Upstate Engineering Concrete EMasonry Allowable Moment Line Top Support Mid -height EBase Designer to determine bar cutoff locations 1,160.0 ft-# 3,480.0 ft-# 5,800.0 ft-# 8,120.0 ft-# 10.440.0 ft-# 0.0 ft-# 2,320.0 ft-# 4,640.0 ft-# 6.960.0 ft-# 9.280.0 ft-# 1. 11.7 2.25 ft pp. ..»»...... ............... ..�.,. _.... m 0.00 ti