Loading...
zorchenkogeo.pdfGEOTECHNICAL ENGINEERING STUDY PROPOSED SINGLE FAMILY RESIDENCE 8910 -178" PLACE SW EDMONDS, WASHINGTON Project No. G-2310 Prepared for Mr. Aleksey Zorchenko 30510 - 25"i Place SW Federal Way, WA 98023 August 7, 2006 GEO GROUP NORTHWEST, INC. 13244 NE 20"' Street, Suite 10 Bellevue, Washington 98005 Phone: (425) 649-8757 sts Group Northwest, nc. Geoiech&Environmental cienti Ists August 7, 2006 Mr. Aleksey Zorchenko 30510 - 25' Place SW Federal Way, WA 98023 Subject: GEOTECHNICAL ENGINEERING STUDY Proposed Single Family Residence 8910 - 178' Place SW Edmonds, Washington Dear Mr. Zorchenko: Project No. G-2310 GEO Group Northwest conducted a geotechnical engineering study for the vacant lot at 8910 - 178"' Place SW in Edmonds, Washington. The project site location is shown on the Vicinity Map, Plate 1. We understand that the lot will be developed with a single family home. Site development plans were not provided for our review. The scope of work performed for this study included a visual reconnaissance of the site, review of the area geologic map, evaluation of the subsurface conditions by excavating three test pits with a trackhoe, probing of the soils as the test pits were being excavated, collection of soil samples, analysis of the soil samples for moisture content, preparation of test pit logs, engineering analysis, and preparation of this report of our findings, conclusions, and geotechnical recommendations addressing constructing a new home on the lot. SITE CONDITIONS AND SITE DESCRIPTION The subject lot (Tax Parcel 00914200001500) is approximately 0.46 acres in size according to Snohomish County parcel records. The lot is irregular in shape, as illustrated on the Site Plan, Plate 2. The lot is bordered by 178`'' Place SW to the north and residential properties to the west, south, and east. The western half of the lot was cleared and the eastern half vegetated with 13240 NE 20th Street, Suite 10 • Bellevue, Washington 98005 Phone 4251649-8757 • FAX 425/649-8758 August 7, 2006 Geotechnical Study 8910 - 178" Place SW, Edmonds, WA G-2310 Page 2 blackberry vines, brush and two fir trees. A topographic site plan was not available at the time this report was prepared. Based on our visual observations, the lot generally slopes up to the south and east, with the eastern portion of the property about 8 feet higher than the west end. A steep road -cut embankment exists adjacent to 1781h Place SW at the east end of the lot. SUBSURFACE CONDITIONS According to the "Geologic Map of the Edmonds East & Part of the Edmonds West Quadrangles, Washington" by James P. Minard, dated 1983, the project site is located near the mapped contact between Transitional Beds (Qtb) and Recessional Outwash (Qvr). Transitional beds are described as consisting of interglacial deposits of silt and clay interbedded with sand lenses. Recessional Outwash generally consists of fluvial sand and gravel deposits that were deposited as the glaciers retreated some 12,000 years ago. We investigated the subsurface_ site conditions by observing the excavation of three test pits with a trackhoe excavator. The depth of the test pits ranged from 7 to 10.2 feet. The location of the test pits are illustrated on the Site Plan, Plate 2. The following describes the soils encountered at the test pit locations. The soils encountered and their thicknesses may be different at other locations on the lot. TP -1 Test Pit TP -1, located at the upper east end of the lot, encountered a thin layer of topsoil underlain by medium dense to dense Sand with gravel and some silt to a depth of about 4 feet. Below 4 feet the soils consisted of very dense gravelly Sand to the total depth of the test pit at 7 feet. TP -2 Test Pit TP -2, located in the middle of the lot, encountered dense to medium dense silty Sand (Fill) to a depth of 3 feet, underlain by loose gravelly Sand (Fill) and a thin layer of topsoil to a depth of about 5 feet. Below the fill and topsoil layer the soils consisted of dense, red- GEO Group Northwest, Inc. August 7, 2006 Geotechnical Study 8910 - 178`h Place SW, Edmonds, WA G-2310 Page 3 brown, gravelly Sand with some silt to a depth of about 7.8 feet underlain by dense, red - brown silty Sand with gravel to the total depth of the test pit at 9 feet. TP -3 Test Pit TP -3, located in the western portion of the lot, encountered about 3 feet of dense silty Sand with gravel (Fill) underlain by a loose mixture of dark brown silty Sand and gray sandy Silt (Fill) to a depth of about 5.3 feet. Below 5.3 feet the soils consisted of very moist, loose to medium dense, silty Sand with gravel to a depth of 10 feet. At 10 feet very stiff to hard Clay was encountered, No groundwater seepage was encountered in the test pits, but the soils were very moist below the fill in TP -3. Groundwater and seepage conditions may vary depending on the time of year and amount of prior precipitation. It appears that the fill soils were used level the western half of the lot where a former depression or swale was located. The sand and gravel soils encountered in TP -1 and below the fill in TP -2 are interpreted to be Recessional Qutwash (Qvr) material. The clay encountered at a depth of 10 feet in TP -3 is interpreted to be Transitional Beds (Qtb), as indicated on the geologic map. SEISMIC CONSIDERATIONS Based on the soil conditions encountered, the site is seismically classified as Site Class C (very dense soil), in accordance with Table 1615.1.1 of the 2003 International Building Code (IBC). Slopes on the site appear to be stable. No signs of slope instability were observed, such as tension cracks, slumps, slides, or scarps. The embankment at the east end of the lot, adjacent to 178'hPlace SW, is a man-made road cut. The potential for liquefaction and/or lateral spreading is very low due to the presence of dense soils and a lack of shallow groundwater at the project site. No known faults intersect the subject property and in our opinion the risk of surface rupture is low as a result of a large magnitude seismic event. No structural mitigation measures are recommended. GEo Group Northwest, Inc. August 7, 2006 Geotechnical Study 8910 - 178"' Place SW, Edmonds, WA DISCUSSIONS AND RECOMMENDATIONS G-2310 Page 4 In general; the layer of fill material, up to 5.3 feet thick, was encountered in the middle and western portions of the site. The upper portion of the fill is generally dense and the bottom portion Ioose. The upper portion appears to be suitable for supporting a driveway, but should not used to support the house. The dense soils that underlie the loose fill are suitable for supporting a residential structure. Based on the results of this study, it is our professional opinion that the site is geotechnically suitable for development with a single family residence. The new home can be supported on a conventional spread footing foundation provided the footings extend down to the dense site soils. Where loose fill soils are present, the loose fill should be removed. If loose to medium dense soils underlie the fill, those soils should be compacted (western portion of lot) and a 2 foot thick crushed rock pad placed on the compacted base soils. Spread footings may be supported on the crushed rock pad or on structural fill placed above the crushed rock in order to bring the subgrade back up to the desired footing elevation, as discussed in the Foundations section of this report. The structural fill should be compacted to 95% of the material's maximum dry density as discussed in the Structural Fill section of this report. Near the existing embankment along 1781h Place -SW, the bottom of the footings should extend below a 1H:1V line (plane) projected up from base of the embankment. The main geotechnical issues for the project include erosion control, site preparation, temporary and permanent cuts and fills, foundation subgrade preparation, foundation soil bearing design criteria, basement and retaining wall design criteria, slab -on -grade floor subgrade preparation and capillary break recommendations, subsurface drainage, and drive subgrade preparation and recommendations. GEo Group Northwest, Inc. August 7, 2006 G-2310 Geotechnical Study Page 5 8910 - 178"` Place SW, Edmonds, WA SITE PREPARATION AND GENERAL EARTHWORK Erosion Control Silt fencing should be installed below the construction area to prevent sediment laden water from leaving the site. The bottom of the silt fence should be buried and washed gravel placed against the base. During wet weather, temporary detention of storm water may be needed, exposed soil should be protected with straw mulch, and cut slopes protected with plastic sheeting. A crushed rock construction entrance should be used to mitigate tracking of mud onto the street. Certs and Fills Under no circumstances should temporary excavation slopes be greater than the limits specified in local, state and national government safety regulations. It is the responsibility of the contractor to provide a safe work environment. Temporary cuts greater than four feet in height should be sloped at an inclination no steeper than 1H:1V (Horizontal:Vertical) in loose to medium dense soils. Steeper temporary cuts up to 1H:2V may be feasible in the dense site soils, provided the stability of the soils are evaluated by the geotechnical engineer at the time of excavation and the cuts are protected from weather. The stability of temporary cuts should be evaluated by the geotechnical engineer if groundwater seepage is encountered. Temporary cuts should not encroach onto the neighboring properties. if the temporary open cut excavations are not feasible due to property line or other constraints then temporary shoring may be required. Permanent cut and fill slopes should be inclined no steeper than 2H:1 V. Permanent 2H:1 V fill slopes should be compacted to a minimum of 90 percent of the material's maximum dry density. Permanent slopes of 3H:1V, or less, are recommended if they are to be mowed and maintained. Once the site development plans are finalized, GEO Group Northwest should provide geotechnical design criteria recommendations for proposed site development features not specifically addressed in this report. Go Group Northwest, Inc. August 7, 2006 Geotechnical Study 8910 - 178' Place SW, Edmonds, WA Structural Fill G-2310 Page 6 Structural fill is defined as compacted engineered fill soils used to support building foundation loads, floor slabs, patios, porches, retaining walls, sidewalks, and pavements. In general, soils containing silt are moisture sensitive and can be difficult to compact to structural fill compaction specifications depending on the material's moisture content and the time of year that construction takes place. Silty site soils are not recommended to be used as structural fill during wet weather unless they are amended by treatment with Portland cement. Soils containing organics, debris and/or rubble, should not be used as structural fill. Structural fill should be placed at the material's optimum moisture content and compacted in 10 - inch thick lifts, or less. Under building.foundations and slab -on -grade floors, structural fill should be compacted to a minimum of 95 percent of the material's maximum dry density, as determined by ASTM Test Designation D-1557 (Modified Proctor). Under driveway pavement and sidewalks structural fill should be compacted to 90 percent, with the exception of the top 12 - inches which should be compacted to 95 percent. Fill adjacent to foundations should be compacted to 90 percent (95 percent if supporting slabs, patio's, porches, or structural elements). Foundations The new home may be supported on a conventional spread footing foundation provided the footings extend down to dense site soil or are supported on structural fill as follows: Where loose fill/topsoil is present, the loose fill/topsoil should be removed. Loose to medium dense soils that underlies the fill/topsoil (such as encountered in the western portion of lot) should be compacted and a 2 foot thick rock pad compacted into base soil. The crushed rock pad may consist of 2 to 6 inch clean rock or recycled concrete (no minus). Spread footings may be supported on the rock pad or on structural fill (meeting 95% compaction specifications) placed above the rock pad in order to bring the subgrade back up to the desired footing elevation. GF,o Group Northwest, Inc. August 7, 2006 Geotechnical Study 8910 - 178` Place SW, Edmonds, WA G-2310 Page 7 To properly transfer building Ioads to the bearing stratum, structural fill and rock below footings should create a prism that extends out and below the footing at 1H:2V (minimum). Therefore, if 5 feet of over -excavation is required, the structural fill/rock pad should extend out and down below both sides of the footing a minimum of 2.5 feet. Near the existing embankment along 178t' Place SW, the bottom of the footings should be deep enough to be below a 1H:IV line (or plane) that is projected up from base of the embankment. The following foundation design criteria are applicable to spread footing foundations that are supported as described above: • Allowable bearing pressure, including all dead and live loads: • Minimum depth to bottom of perimeter footing below adjacent final exterior grade: • Minimum depth to bottom of interior footings below top of floor slab: • Minimum width of strip wall footings: • Minimum lateral dimension of column footings: • Estimated Post -construction settlement: — Across building width: 2,000 psf 24 inches = 12 inches = 16 inches = 24 inches 112 inch = 112 inch A one-third increase in the above allowable bearing pressures can be used when considering short-term transitory wind or seismic loads. Lateral loads can also be'resisted by friction between the foundation and the supporting compacted fill subgrade or by passive earth pressure acting on the buried portions of the foundations. For the latter, the foundations must be poured "neat" against the existing undisturbed soil or backfilled with a compacted fill meeting the requirements of structural fill. Our recommended parameters are as follows: GEo Group Northwest, Inc. August 7, 2006 Geotechnical Study 8910 - 178' Place SW, Edmonds, WA - Passive Pressure (Lateral Resistance) • 350 pcf equivalent fluid weight for dense site soils and structural fill - Coefficient of Friction (Friction Factor) • 0.35 for dense site soils and structural fill Slab -on -Grade Floors G-2310 Page 8 Slab -on -grade floors should be supported on dense site soils, on compacted engineered structural fill that extends down to dense soil, or on a subgrade prepared as follows: Remove loose fill/topsoil, compact the underlying soils if loose to medium dense. Place structural fill consisting of a granular material, such as a sand/gravel pit run, to bring the subgrade back up to the desired elevation. Compact the structural fill to 95% of the material's maximum dry density, in accordance with structural fill specifications, Slab -on -grade floors should be -placed on a capillary break to prevent wicking of moisture through the slab. The capillary break should consist of a minimum of six (6) inch thick free - draining layer of 1.5 inch minus gravel containing no more than five (5) percent fines passing the No. 4 (114 -inch) sieve. To reduce water vapor transmission through the slab we recommend installing a 10 -mil reinforced vapor barrier, such as Moistop' by Fortifiber Corporation, between the capillary break and concrete floor slab, Two to four inches of sand may be placed over the membrane for protection during construction (optional). Drainage If feasible, the finished ground of the site should be graded such that surface water is directed away from the building structure. During construction, water should not be allowed to stand in areas where footings, slabs, or pavements are to be constructed. It is recommended that a subsurface footing drain be installed around the perimeter foundation footing. The footing drain should consist of a four (4) inch minimum diameter, perforated, rigid drain pipe laid at or near the bottom of the footing with a gradient sufficient to generate flow. GEo Group Northwest, Inc. August 7, 2006 G-2310 Geotechnical Study Page 9 8910 - IV' Place SW, Edmonds, WA The drain line should be bedded on, surrounded by, and covered with a free -draining rock and the drain rock should be protected with geotextile filter fabric, such as Miraf MON, or equivalent; as shown on Plate 3, Typical Footing Drain. Roof, yard, and other drain lines should not be connected to the footing drain system. The footing drain should be separately tightlined to the storm drain. We recommend that sufficient cleanouts be installed at strategic locations to allow for periodic maintenance of the footing drains and roof down -spout tightline systems. The lot is underlain by clay Transitional Beds that will act as a infiltration barrier. Infiltration of surface water from roof, yard and other drains is not recommended. Infiltration of water into the ground above the steep embankment along Puget Sound should be minimized. Storm water should be discharged to the storm drain system. Driveway Subgrade The adequacy of driveway pavements is strictly related to the condition of the underlying subgrade. If this is inadequate, no matter what pavement section is constructed, settlement or movement of the subgrade will be reflected up through the paving. Where existing fill soils are present, the driveway should be supported on a minimum of 3 feet of dense compacted material. Prior to pouring the driveway, the subgrade should be proof -rolled with a loaded dump truck and areas of soft, wet, or unstable subgrade should be removed and replaced with a granular structural fill or crushed rock. Inclusion of reinforcement steel is recommended in a concrete driveway with doweling across expansion joints. GEo Group Northwest, Inc. August 7, 2006 G-2310 Geotechnical Study Page 10 8910 - 178` Place SW, Edmonds, WA LIMITATIONS This report has been prepared for the specific application to the subject project. The findings and recommendations stated herein are based on our field observations, the subsurface conditions encountered in our site exploration, our experience, and judgement. The recommendations are our professional opinion derived in a manner consistent with the level of care and skill ordinarily exercised by other members of the profession currently practicing under similar conditions in this area and within the budget constraint. No warranty is expressed or implied. In the event that soil conditions vary during site work, GEo Group Northwest, Inc. should be notified and the recommendations herein re-evaluated, and where necessary, be revised. GEo Group Northwest, Inc. should be retained to review the final design plans to confirm the validity of the recommendations contained in this report if there are significant changes to the project as described herein. PLAN REVIEW AND CONSTRUCTION MONITORING It is recommended that we be retained to perform a general review of the final design and specifications to verify that the earthwork, foundation, and other recommendations have been properly interpreted and implemented in the design and engineering plan documents. During construction, GEO Group Northwest should provide geotechnical monitoring/inspection services. This will allow us to confirm that the subsurface conditions are consistent with those described in this report and allow design changes in the event subsurface conditions differ from those anticipated prior to the start of construction. It will allow us to evaluate whether the geotechnical aspects of the construction activities conform to.the contract plans and specifications. GEo Group Northwest, Inc. August 7, 2006 G-2310 Geotechnical Study Page I I 8910 - 178` Place SW, Edmonds, WA Please contact us if you have any questions regarding this report or if additional information is needed. Sincerely, GEo Group Northwest, Inc. Wade J. Lassey Engineering Geologist William Chang, P.E. Principal Attachments: Illustrations Plate I - Vicinity Map Plate 2 - Site PIan Plate 3 - Typical Footing Drain Detail Appendix A Test Pit Logs GEo Group Northwest, Inc. �was6 � 4 '3 .�` . Engineerk-1g 111E�`' Wade J, L.assey ILLUSTRATIONS G-2310 Adapted from "The Thomas Guide," 2005. 0 1000, 2000' Approximate Scale: 1 inch =1000 feet VICINITY MAP Group Northwest, Inc. 8910 -178th PLACE SW Geotechnical Engineers, Geologists, & Environmental Scientists EDMONDS, WASHINGTON SCALE As Shown DATE 8/7/06 MADE WJL CHKD WC JOB NO. G72310 PLATE 1 LEGEND Test Pit Number & Approximate Location TP -1 Adapted from Snohomish County Online Property Information http://gis.co.snohornish.wa.us/maps/propteryt/MapFrame.htm SITE PLAN Group Northwest, Inc. ALEKSEY ZORCHENKO LOT Geotechnical Engineers, Geobgists, x 8910 - 178th PLACE SW Environmental Scientists EDMONDS, WASHINGTON SCALE As Shown DATE 8/7/06 MADE WJL CHKD WC JOS No. G-2310 PLATE 2 Basement Wall Slope to drain VERTICAL DRAIN - 0 0 ° 0 MAT o ° o ° p (Miradrain 6000 O 0 0 or equivalent) COMPACTED 0 ONSITE MATERIAL o o WATERPROOFING �/ c7 0 c 0 00 0 0 0 0 fl0 ° ° VAPOR .BARRIER 0 0 ° O GEOTEXTILE.. ;.. "' ...... &R AK FILTER FABRIC FOOTING (Mirafi 140 N, or _ equivalent) '' `— FOOTING DRAIN WASHED DRAINROCK Minimum 4 -inch diameter rigid PVC perforated pipe with positive gradient to discharge NOT TO SCALE NOTES: 1.) Do not replace rigid PVC pipe with flexiible corrugated plastic pipe. 2.) Perforated PVC pipe should be tight jointed and laid with perforations down, with positive gradient to discharge. 3.) Do not connect roof downspout drains into the footing drain line system. 4.) Backfill on the exterior of the foundation basement wall should be compacted to a minimum of 90% of the maximum dry density based on ASTM D 1557 - Modified Proctor (95% if supporting structural elements, such as porches, patio's, or slabs). - FOOTING DRAIN DETAIL Group Northwest, Inc. ALEKSEY ZORCHENKO LOT �.r Geotechnical Engineers, Geologists, & 8910 -178th PLACE SW Environmental Scientists EDMONDS, WASHINGTON SCALE NONE DATE 8/7/06 MADE WIL CHKD WC JOB NO. G-23 10 PLATE 3 APPENDIX A G-2310 TEST PIT LOGS LEGEND OF SOIL CLASSIFICATION AND PENETRATION TEST UNIFIED SOIL CLASSIFICATION SYSTEM (USCS) MAJOR 131VISION GROUP TYPICAL DESCRIPTION LABORATORY CLASSIFICATION CRITERIA SYMBOL WELT. GRADED GRAVELS, GRAVEL -SAND Ca = (D601 DID) gteator than 4 CLEAN GW MIXTURE, LITTLE OR NO FINES Cc P30') 1 (1310 * OW) between 1 3 GRAVELS DETERMINE and PERCENTAGES OF GRAVELS (Gt[te or no POORLY GRADED GRAVELS, AND GRAVEL -SAND GRAVEL AND SANp re (MaThan Haff Dines) GP MIXTURES LITTLE OR NO FINES FROM GRAIN SIZE NOT MfOrfING ABOVE REQUIREMENTS Coarse Grains DISTRIBUTION ATTERBERG LIMITS BELOW GRAINED SOILS LargarThan No. 4 CURVE Si—) DIRTY GM SILTY GRAVELS, GRAVELSAND-SILT MIXTURES A" LINE GRAVELS NT or P.L LESSTHAN 4 OF FIM CLAYEY GRAVELS, GRAVEL -SAND -CLAY A7TERBE G UMTI S ABOVE (with some EXCEEDS 12% tines) GC MIXTURES COARSEGRAFNED "AA""UNE SOILS ARE at RL MORETHAN T CLASSIFIED AS SANDS CLEAN SW WELL GRADED SANDS, GRAVELLY SANDS, FOLLOWSS Cu = (08011110) greater than 8 LITTLE OR NO FINES Cox (D302)1 @10. D60) buNmen 1 and 3 SANDS (More Than Hail Mare Than Half by Cwrse Grains Qiltfe or no SP POORLY GRADED SANDS, GRAVELLY SANDS, -4,9% Fine Grained NOT MEETING ABOVE REQUIREMENTS. Weight Larger Smaller Than Na. fines) LITTLE OR NO FINES GW, GP SW Thep No. 2DO 4 Slave) ATfERBt=RG BELOW Siena DIRTY SM SILTY SANDS, SANDSfLT MIXTURES > 12% Fine Grained- LINE 'A' LINE SANDS GM, GC, SM, SC CONT84T OF with P.L LESS THAN 4 FrNEs ATTERBE-RG UMfI'S ABOVE (with some5 to 12% Fina ExcEEDs 12% fines) SC CLAYEY SANDS; SAND-CL.AY MXWRES Grained: use dual "A" UNE symbols with P,L MORE THAN 7 SILTS Liquid Umit INORGANIC SILTS, ROCK FLOUR, SANDY SILTS (Balow A-L.ine on < 50% ML OF SLIGHT PLASTICITY 60 Plasticity Char; CHART A -Una Liquid Limit INORGANIC SILTS, MICACEOUS OR FINE-GRAINED Negligible so.ASSING SOILS Organic) > 56% MH DIATOMACEOUS, FINE SANDY OR SILTY SOIL _]EVE rNO.CH or OH CLAYS CLAYS Liquid Limit INORGANIC CLAYS OF LOW PLASTICITY, 40 CL GRAVELLY, SANDY, OR SILTY CLAYS, CLEAN � (Above A Une on <30% CLAYS z Plastic" Chart, Uqutd LimitINORGANIC CLAYS OF HIGH PLASTICITY, FAT Negligible 30}} F Organic) > 54% - CLAYS C3 CL or OL /1 1 More Than Half by 20-- 0 Weight Larger Liquid Limit ORGANIC SILTS AND ORGANIC SILT! CLAYS OF jorMH ar OH Than No. 200 ORGANIC SILTS & < 5096 OL LOW PLASTICITY C Sieve CLAYS 10 (Below A -Line on 7 Plasticity Chart) Liquid Limft 1 OH ORGANIC CLAYS OF HIGH PLASTICITY 4 AA OL M >' 0 0 10 20 30 40 50 60 70 80 W 100 110 HIGHLY ORGANIC SOILS Pt PEAT AND OTHER HIGHLY ORGANIC SOILS LIQUID LIMIT (%) SOIL PARTICLE SIZE GENERAL GIJiDANCE OF SOIL ENGINEERING PROPERTIES FROM STANDARD PENETRATION TEST (SPT) U.S. STANDARD SIEVE FRACTION Passing Retained SANDY SOILS SILTY & CLAYEY SOILS Size Size Sieve (MM){m113( Sieve Blow Counts Relative Density Friction Angle Description Blow Counts Unconfined Sbength Description SILT 1 CLAY #200 0.075 N % (D, degree N qu tit SAND 0-4 0-15 VeryLOD" 42 -015 Vey soft FINE #40 0.425 #200 0.075 4-10 15-35 25-30 Loose 2-4 0-25-0.50 Soft MEDIUM #10 200 1140 0.425 10-30 35.65 28-35 MediumDonse, 4-8 D-50-1.00 Madium Skiff COARSE #4 4.75 #10 200 30 -SD > 50 65-86 85-100 36-42 38-48 Dense VeryDense 8-15 16-30 1.00 - 200 2.00-4,00 Stift Very Stiff GRAVEL FINE 19 #4 4-75 1 1 1> 30 > 4.00 Hard COARSE 76 19 —+ / Group Northwest, Inc. COBBLES 78 mm to 203 mm BOULDERS >203mm , Geatechniral Engineers, Geolo gists, & EnVLrmmmentaiScientists ROCK I >78mm FRAGMENTS IE F 13240 NE 20th Street, Suite 12 Bellevue, WA 98005 5 Phone (425) 6498757 Fax (425) 649A758 PLATE Al ROCK >0.76 cubic meter in volume TEST PIT NO. TP -1 LOGGED BY W3L TEST PIT DATE: 7/14/06 GROUND ELEV. feet lam) DEPTH ft. USCS SOIL DESCRIPTION Sample No. Moisture % COMMENTS ft. SM TOP SOIL, dark brown silty SAND, loose dry No. % COMMENTS — — -- Sl 7.3 SM some roots and occasional wood debris (FILL) S 1 8.8 - Probed 6" at SSP -SAND with gravel and some silt, tan, fine to medium ft -------------------------------- SM grained, medium dense to dense, damp S2 5.4 -- — — — — — — — — — — — — — — — — — — — — — — — 52 8.4 -Probed<l" 5 at4ft 5-- GP Gravelly SAND, tan, very dense, damp S3 6.1 S3 4.5 Total Depth = 7 feet Gravelly SAND with some silt, red -brown, fine to medium 5 5 ft SM No Water Seepage Encountered Location: East end of lot I. S4 7.5 10 SM Silty SAND with gravel, red brown, dense, some I S5 3.2 TEST PIT NO. TP -2 LOGGED BY W1L TEST PIT DATE: 7114/06 GROUND ELEV. feet ( ) DEPTH Sample Moisture ft. USCS SOIL DESCRIPTION No. % COMMENTS Silty SAND with gravel, brown, dense to medium dense, SM some roots and occasional wood debris (FILL) S 1 8.8 -Probed 1" to 8" -------------------------------- SP- Gravelly SAND with some silt, mixed red -brown & dark SM brown, loose, damp, some charcoal & roots (FILL) 52 8.4 - Probed 1.5 f1a#oft 5-- SM TOPSOIL layer, dark brown silty SAND, loose, dry S3 6.1 - Probed 3" at SP- Gravelly SAND with some silt, red -brown, fine to medium 5 5 ft SM grained, dense, damp I. S4 7.5 SM Silty SAND with gravel, red brown, dense, some I S5 3.2 cobbles/boulders to 12 inches, damp 10 Total Depth = 9 feet No Water Seepage Location: Middle of lot Group Northwest, Inc. Geolechnkal Engineers, Geologists, & Environmental Scientists TEST PIT LOGS VACANT RESIDENTIAL LOT 8910 -178TH PLACE SW EDMONDS, WASHINGTON ,JOB NO. G-2310 DATE 12/12/05 PLATE A2 TEST PIT - NO. TP -3 LOGGED BY WJL TEST PIT DATE: 7/14106 GROUND ELEV. feet it) DEPTH ft. USCS SOIL DESCRIPTION Sample NO. Moisture % COMMENTS 5 Silty SAND with gravel, dark brown, dense, damp, some wood and platic (FILL) - Probed 1" at S1 10.8 2 ft SM--------,_� _ �_----- - Probed 17"„ Silty SAND with gravel and sandy SILT, dark brown and at 3.5 ft 5 gray, mixed, loose, moist (FILL) S2 13.1 i___----___ ._.� -Probed 19” at5ft SM Silty SAND with gravel, brown, fine to medium grained, loose to medium dense, very moist S3 11.8 10 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ S4 40.1 CL CLAY, tan, moderate plasticity, very stiff to hard, damp Total Depth= 10.5 feet No Water Seepage Encountered Location West end of lot I TEST PIT NO. I LOGGED BY TEST PIT DATE: GROUND ELEV. feet (1) DEPTH ft. USCS SOIL_ DESCRIPTION Sample No. Moisture % COMMENTS 5 Group Northwest, Inc. Geotechnical Engineers, Geologists, & Environmental scientists TEST PIT LOGS VACANT RESIDENTIAL LOT 8910 -178TH PLACE SW EDMONDS, WASHINGTON JOB NO. G-2310 DATE 12/12/05 PLATE A3