Loading...
JAIIA CAFE SUBMITTALLOW VOLTAGE SYSTEMS BY ro omm PROTECTION & COMMUNICATIONS INC. Fire Alarm System - Product Data & Battery Calculations - for EDMONDS WATERFRONT 10032 EDMONDS WAY SUITE 100 EDMONDS WA 98020 Protection & Communications, Inc. 220 RAILROAD AVE EDMONDS WA 98020 Phone: 425.774.9099 Fax: 425.774.6317 Sales Account Engineer -LYLE WELLS Project #PRO-C-4345 (E)POTTER The Symbol of Protection Features • 24VDC units have field selectable candela options of 15, 30, 60, 75 & 110 • Super -Slide® Bracket - Ease of Supervision Testing • Checkmate® - Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system, install mounting bracket, then install signals • Documented lower installation and operating costs • Switch selection for high or low dBA • Switch for chime, whoop, mechanical and 2400Hz tone • Tamperproof re-entrant style grill • Switch for continuous or temporal 3 tone (not available on whoop tone) • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) • Faceplate available in red or off-white Description The S-24/HS-24 Series is a low profile strobe and horn/ strobe combination that offers dependable audible and visual alarms and the absolute lowest current available. The S-24 & HS-24 Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The Strobe and Horn/Strobe offers a continuous or sync temporal three in 240011z and mechanical tone, a chime and whoop tone. All tones are easy for the professional to change in the field by the use of switches. The S-24 & HS-24 Series has a minimal operating current and has a minimum flash rate of 1Hz regardless of input voltage. This Series is shipped with a standard 4" metal mounting plate which incorporates the popular Super -Slide® feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The S-24/HS-24 also features the patented Checkmate® - Instant Voltage Verification feature which allows the installer to check the voltage drop draw and match it to the blueprint. The S-24 & HS-24 Series appliances are ANSI/UL 464 and ANSI/UL 1971, listed for use with fire protective systems and are warranted for three years from date of purchase. S-24 & H S-24 Selectable Candela Strobe & Horn/Strobes /j y , I1111J�_ i U� LISTED S3247 Technical Specifications Single or Double gang, 4" Mounting Options square box, and AVBB surface mount back box Terminals Screw -Clamp Type Wire Gauge 18 — 12 AWG Operating Temp 32°F — 120°F (0° — 49°C) Height — 5" Dimensions Width — 4.5" Depth — 2.5" Shipping Weight 1.05 lbs Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830054-REV C 6/17 PAGE 1 OF 4 (E)POTTER The Symbol of Protection TONE SWITCH POSITION 3 4 5 Mechanical Temporal 3 ON ON ON Mechanical Continuous OFF ON ON 2400 Hz Temporal 3 ON OFF ON 2400 Hz Continuous OFF OFF ON Chime Temporal 3 ON ON OFF Chime Continuous OFF ON OFF Whoop ON OFF OFF Whoop OFF I OFF OFF NOTE: • Switch Positions IThe and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON = HIGH dBA • Switch Position 6 OFF = LOW dBA rnnrlcln Cnlcr4inn Super Slide® Mounting Bracket Allows the installer to pre -wire the system, test for system supervision, remove the signal head until occupancy, switch out signals without changing mounting brackets and has locking edge connector for snap -in -place installation. S-24 & H S-24 Selectable Candela Strobe & Horn/Strobes Switch Locations LMEMO 00 NNEE M M MEMO 0 'Manin Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830054-REV C 6/17 PAGE 2 OF 4 (E)POTTER ® The Symbol of Protection S-24 24 VDC Selectable Candela, Low Profile Evacuation Strobe S-24 & H S-24 Selectable Candela Strobe & Horn/Strobes Model Nominal Candela (ANSI/UL Part Number Number Voltage 1971) S-24WR 4890010 24 VDC 15, 30, 60, 75, 110 S-24WW 4890011 24 VDC 15, 30, 60, 75, 110 HS-24 24 VDC Selectable Candela, Low Profile Evacuation Strobe Candela (ANSI/ Reverberant dBA at 10 In Anechoic Room at Model Number Part Number Nominal Voltage UL 1971) ft, per ANSI/UL 464 loft HS-24WR 4890030 24 VDC 15, 30, 60, 75, 110 62-82 100 HS-24WW 4890031 24 VDC 15, 30, 60, 75, 110 62-82 100 S-24 & HS 24 Strobe Current Ratings 24 VDC (16 - 33 Volts) Candela 24 VDC UL Max 15 cd 30 mA 42 mA 30 cd 35 mA 58 mA 60 cd 66 mA 97 mA 75 cd 80 mA 116 mA 110 cd 103 mA 161 mA S-24 & HS-24 Horn Ratings Model Designations: W = Wall mount R = Red Faceplate W=White Faceplate All units are available in plain (no lettering) Plain units are non -returnable. "ALERT" bezel available for order. "AGENT" bezel available for order. Horn Mode Horn Decibel Levels Horn Current Ratings Minimum SPL at 10 ft, per ANSI/UL 464 (HIGH) Minimum SPL at 10 ft, per ANSI/UL 464 (LOW) Regulated 24 VDC Max Operating @ High Setting (mA) Temp 3 (2400 Hz) 78 dBA 71 * dBA 28 mA Temp 3 (Mechanical) 76 dBA 70* dBA 25 mA Temp 3 (Chime) 70* dBA 66* dBA 15 mA Continuous (2400 Hz) 81 dBA 74* dBA 28 mA Continuous (Mechanical) 80 dBA 72* dBA 25 mA Continuous (Chime) 70* dBA 66* dBA 15 mA Whoop 82 dBA 69* dBA 56 mA NOTES. • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power see installation manual. • Potter does not recommend using a coded or pulsing signaling circuit with any of our strobe products. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830054-REV C 6/17 PAGE 3 OF 4 (E)POTTER The Symbol of Protection S-24 & HS-24 Series Wiring Diagram UL Listed Control Signal Panel S+ S+ S- H+ H- Supervised 0 0 Signal Circuit n S-24 & HS-24 Selectable Candela Strobe & Horn/Strobes UL Listed Control Signal Panel S- H+ H- Supervised 0 a Signal Circuit END LINE RESISTOR Signal I I Signal END OF LINE RESISTOR END OF LINE RESISTOR Notes: All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn, and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC TECHNICAL SUPPORT AT 1-866-956-1211 Architect & Engineering Specifications The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories, Inc. per ANSI/UL 1971 and/or ANSI/UL 464. The notification appliance shall also be listed with Factory Mutual Listing Service (FM) and the California State Fire Marshal (CSFM). The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 21-lz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830054-REV C 6/17 PAGE 4 OF 4 SMARTWIRE GL/O T E C H N O L O G V� CABLE SPECIFICATIONS DESCRIPTION 14 AWG 2 Conductor twisted Bare Copper, Non -Shielded Plenum Fire Alarm, FPLP (UL) CONDUCTOR 14 (Solid Bare Copper) INSULATION Low -Smoke PVC .010" COLOR CODE Black/Red LAY LENGTH 3.75" LHL (3.2 TPF) SHIELD N/A DRAIN WIRE N/A JACKET Low -Smoke PVC .018" - JACKET COLOR Red Jacket MARKING FIRE/LIFE SAFETY CONTROL CABLE INIT. / IND. DEVICE / ZONE A B C D E 0 1 2 3 4 5 6 7 8 9 14 AWG FPLP (UL) ROHS MADE IN THE USA OVERALL DIAMETER 206" Nom CABLE WEIGHT 36 Lbs/Mft. CAPACITANCE 26 pF/Ft. Nom. IMPEDANCE 72 Ohms DC RESISTANCE 2.57 Ohms/Mft @ 20 deg. C TEMPERATURE RATING 0 C to 75 C / 300 Volt INDUSTRY STANDARDS FLAME RATING Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test AGENCY APPROVALS NEC Article 800; FPLP (UL), RoHS Compliant, Made in the USA ®MADE IN AMERI All specifications referenced are nominal measurements unless otherwise noted.