Loading...
07-23-2019-mock-residence-retaining-wall-reconstruction-18b291-01-field-report-other-report-f209760 (1)k Materials Testing & Consulting, Inc. Geotechnical Engineering &Consulting •Special Inspection •Materials Testing •Environmental Consulting " " Mock Residence Retaining Wall Reconstruction - 1813291-01 - Field Report: Other: Report#F209760 CLIENT Darrin Mock DATE 07/23/2019 PROJECT LOCATION 21100 88th Place West Edmonds WA PERMIT # Inspection Information: Inspection Date: Time Onsite: 01:15 Weather Cloudy, 60s, dry 07/23/2019 PM Conditions: Inspection Performed: Other Comments: MTC visited the site as requested by the client to observe subgrade conditions for the new retaining wall footing, and to verify pin pile installation to refusal. At this time, the contractor had excavated for the new block wall foundation from the overhanging area of structure south to the end of the wall extending along the exterior patio south of the house. Exposed soils at the cut elevation consisted of either intact native glacial till, generally light brown silty sand with gravel, or recompacted native silty sand overburden oils of similar content. Conditions were as anticipated per the geotech report but varying locally in terms of depth to till. The contractor installed a series of eleven 63" x 2" steel pin piles along the West half of the retaining wall footprint as added support which were driven partially through the till subgrade (based on embed depths). MTC observed the contractor proof -test these piles by redriving to verify refusal criteria were met. A hand -operated pneumatic hammer was used at full force. Less than one inch of penetration was observed for 60 seconds of sustained driving, consistent with the recommended and typical refusal criteria for the pile size and capacity required. Approximate pile embedment (from prepared grade) as determined by the contractor's information and direct measurements is recorded below listed E to W: 1. 55" 2. 53" 3. 29" 4. 24" 5. 44" 6. 19" 7. 25" 8. 37" 9. 50" 10. 49" 11. 27" To the best of MTC inspector's knowledge, the above -described work was performed in general accordance with project specifications and approved plans. Images: Corporate • 777 Chrysler Drive • Burlington, WA 98233 • Phone 360.755.1990 • Fax 360.755.1980 Regional Offices: Olympia Bellingham Silverdale Tukwila 360.534.9777 360.647.6111 360.698.6787 206.241.1974 Visit our website: www.mtc-inc.net Mock Residence Retaining Wall Reconstruction - 1813291-01, 0712312019, #F209760, Page 1 of 2 MTC 1 Materials Testing & Consulting, Inc. Geotechnical Engineering & Consulting • Special Inspection • Materials Testing • Environmental Consulting " UPLOADED: 07/23/2016 13:46:19 Overview of conditions Looking W REPORTED BY: Jeff Voigt REVIEWED BY: John Gillaspy, Project Manager Corporate • 777 Chrysler Drive • Burlington, WA 98233 • Phone 360.755.1990 • Fax 360.755.1980 Regional Offices: Olympia Bellingham Silverdale Tukwila 360.534.9777 360.647.6111 360.698.6787 206.241.1974 Visit our website: www.mtc-inc.net Mock Residence Retaining Wall Reconstruction - 18B291-01, 0712312019, #F209760, Page 2 of 2