Loading...
07-08-2019-mock-residence-retaining-wall-reconstruction-18b291-01-field-report-geotechnical-consulting-report-f208799 (1)MTC Materials Testing & Consulting, Inc. Geotechnical Engineering & Consulting • Special Inspection • Materials Testing • Environmental Consulting Mock Residence Retaining Wall Reconstruction - 1813291-01 - Field Report: Geotechnical consulting: Report #F208799 CLIENT Darrin Mock DATE PROJECT LOCATION 21100 88th Place West Edmonds WA PERMIT # Inspection Information: Inspection Date: Time Onsite: 8:30 Weather Sunny, 60s, dry 07/08/2019 AM Conditions: Inspection Performed: Geotechnical consulting Comments: 07/08/2019 MTC visited the site as requested by the client to verify native subgrade for the new retaining wall footing, and to verify pin pile installation to refusal of required piles done to date. At this time, the contractor had excavated for the new block wall foundation from near the edge of the overhanging structure south to the end of the wall planned to extend along the exterior patio south of the house. Exposed soils at the cut elevation consisted of undisturbed and compacted native glacial till, generally light brown silty sand with gravel. MTC noted minimal penetration up to — 1/2" maximum with a standard T-probe. We confirmed the subgrade as prepared as suitable for direct support of a cast -in -place concrete strip or grade beam foundation which will in turn support the small block geogrid wall. The contractor had also installed a series of 2" steel pin piles in this area as added support which were driven partially through the till subgrade. We agreed these elective piles were suitable to remain below the wall footing alignment. The first four pin piles were also installed for the block wall that will be topped with a structural slab tied into the existing house foundation in the vicinity of the house overhang. MTC observed the contractor proof -test these piles by redriving to verify refusal criteria were met. A hand -operated pneumatic hammer was used at full force. Less than one inch of penetration was observed for 60 seconds of sustained driving, consistent with the recommended and typical refusal criteria for the pile size and capacity required. Approximate pile embedment as determined by the contractor's information and direct measurements is recorded below (from current grade): Pile 1: T-3" Pile 2: T-Y Pile 3: T-10" Pile 4: T-10" MTC agreed to return for further inspections of wall foundation and pile install preparations once the project progresses into the overhang area. While on site, the client/contractor discussed needing to use varying wall heights versus the original plan, and we were shown a schematic of approximate foundation versus final grades for the wall extending along the SW corner and south of the house. MTC agreed to evaluate modifications to the design geogrid length at request of the client for wall heights exceeding the original plan height. At this time the top -of -foundation elevation is still to be determined between the client and structural engineer. To the best of MTC inspector's knowledge, the above -described work was performed in general accordance with project specifications and approved plans. Images: Corporate • 777 Chrysler Drive • Burlington, WA 98233 • Phone 360.755.1990 • Fax 360.755.1980 Regional Offices: Olympia Bellingham Silverdale Tukwila 360.534.9777 3 60.64 7.6111 360.698.6787 206.241.1974 Visit our website: www.mtc-inc.net Mock Residence Retaining Wall Reconstruction - 1811291-01, 0710812019, #F208799, Page 1 of 2 MTC ;1 UPLOADED: 07/08/2019 19:44:41 End of current trench for wall footing Materials Testing & Consulting, Inc. Geotechnical Engineering & Consulting • Special Inspection • Materials Testing • Environmental Consulting UPLOADED: 07/08/2019 19:44:40 n UPLOADED: 07/08/2019 19:44:42 Proof -testing UPLOADED: 07/08/2019 19:44:43 Looking along installed piles back side of house toward overhang REPORTED BY: Kevin Walters REVIEWED BY: John Gillaspy, Project Manager Corporate • 777 Chrysler Drive • Burlington, WA 98233 • Phone 360.755.1990 • Fax 360.755.1980 Regional Offices: Olympia Bellingham Silverdale Tukwila 360.534.9777 360.647.6111 360.698.6787 206.241.1974 Visit our website: www.mtc-inc.net Mock Residence Retaining Wall Reconstruction - 18B291-01, 0710812019, #F208799, Page 2 of 2