BLD2020-0539_Manufacturer_Specifications_and_Installation_Instructions_5.27.2020_8.20.24_AMAAM?AW S*R66rd, HEATING & AIR CONDITIONING Submittal Split System Cooling 4A7A3043A1000N Note: "Graphics in this document are for representation only. Actual model may differ in appearance." T Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. March 2017 4A7A3043A-S U 13-1 B-E N "Hingersoll Rand 4*wl ao S*mdard HEATING & AIR CONDITIONING SERVICE PANEL ELECTRICAL AND REF COMPONENT CLEARANC PER PREVAILING COD TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12") FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. T__ ELECTRICAL SERVICE PANEL 22.2 (7/8) DIA. HOLE LOW VOLTAGE 28.6 (1-1/8) DIA. K.O. *IT 22.2 (7/8) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPL' K 25 (I) A { r FI F _jr,7d K.O. FOR ALTERNATE ELECTRICAL ROUTING LIOUID LINE SERVICE VALVE, / "E' I,D. FEMALE BRAZE J CONNECTION WITH I/4" SAE FLARE PRESSURE TAP FITTINGS. GAS LINE 1/4 TURN BALL SERVICE VALVE, "D" I.D. FEMALE BRAZED CONNECTION WITH I/4" SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H 3 K 4A7A3043A 4 741 (29-1/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 143 (5-5/8) 83 (3-1-4) 206 (8-1/8) 70 (2-3/4) 508 (20) Sound Power Level A -Weighted MODEL Sound Power Full Octave Sound Power(dB) Level[dB(A)] 63 Hz* 125 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 8000 Hz Hz Hz 4A7A3043A1 72 77.6 68.3 67.4 65.6 67.4 58.2 54.1 47.6 Note: Rated in accordance with AHRI *For Reference Only Standard 270-2008 4A7A3043A-SUB-1 B-E N 4*w�ooS*vdard HEATING & AIR CONDITIONING Product Specifications OUTDOOR UNIT (a) (b) 4A7A3043A1000N POWER CONNS. — V/PH/HZ M 208/230/1/60 MIN. BRCH. CIR. AMPACITY 22 BR. CIR. PROT. RTG. — MAX. (AMPS) 35 COMPRESSOR DURATION@ -SCROLL NO. USED — NO. STAGES 1 — 1 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS (d)— L.R. AMPS 16.7— 109 FACTORY INSTALLED START COMPONENTS (e> NO (Uses BAYKSKT263) INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 27.5 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0IN. W.G. M 4171 NO. MOTORS — HP 1-1/5 MOTOR SPEED R.P.M. 835 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 1.05 OUTDOOR COIL — TYPE SPINE FIN — ROWS — F.P.I. 1-24 FACE AREA (SQ. FT.) 19.07 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. — R-410A (O.D. UNIT) (g) 6 LBS., 7 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) 7/8 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 120F DIMENSIONS H X W X D CRATED (IN.) 34.4 x 35.1 x 38.7 WEIGHT SHIPPING (LBS.) 216 NET (LBS.) 184 Optional Accessories: Anti -short Cycle Timer TAYASCT501A Evaporator Defrost Control AY28XO79 Rubber Isolator Kit BAYISLT101 Extreme Condition Mount Kit BAYECMT004 Start Kit BAYKSKT263 Crankcase Heater Kit BAYCCHT301 Seacoast Kit BAYSEAC001 Low Ambient Kit BAYLOAM103 Refrigerant Lineset (I) TAYREFLN3* Service Valve Panel Cover TAYSVPANL3343AA (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. M No means no start components. Yes means quick start kit components. Optional kit shown. M Standard Air — Dry Coil — Outdoor (g) This value approximate. For more precise value see unit nameplate. (h) Max. linear length 60 ft.; Max. lift — Suction 60 ft.; Max. lift — Liquid 60 ft. For greater length consult refrigerant piping software Pub. No. 32-3312-0* (* denotes latest revision). (I) * = 15, 20, 25, 30, 40 and 50 foot lineset available. 4A7A3043A-SUB-1 B-EN Awe� aw SAwdzrd, HEATING & AIR CONDITIONING Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test . The base is made of a CMBP-G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. Thermostats —Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Accessory Description and Usage Anti -Short Cycle Timer — Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporation Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV. Rubber Isolators — Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start Kit — Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. 2. High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. 3. Low Temperature Heating 17°F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions — (Noise rating numbers are determiend with the unit in cooling operations.) Standard Noise Rating number is at 95°F outdoor air. 4A7A3043A-S U 13-1 B-E N Aw aw SAwdzrd, HEATING & AIR CONDITIONING Schematic Diagrams Figure 1. 3.5 and 4.0 Ton Model TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES CIF FAN CAPACITOR I -------I CN WIRECONNECTOR � —I r----START KIT ---_- C� CPR COMPRESSOR (rL � BAYKSKT263 CP RUN CAPACITOR J o7 CS CS STARTING CAPACITOR WMMS- ('�'� CSR-I CSR m CSR CAPACITOR SWITCHING RELAY -0�------- RD�� �� �� �������1, �r Ci B!71 - �a----BK/BL------ MS-2 F INDOOR FAN RELAY 1 I 2 5 HPCO HIGH PRESSURE CUTOUT SWITCH R ; LPCO LOW PRESSURE CUTOUT SWITCH CAPACITOR E El IOL INTERNAL OVERLOAD PROTECTOR 1 QD BR QR�Q SN SYSTEM ON -OFF SWITCH F A N P "CLR MS COMPRESSOR MOTOR CONTACTOR MTR 6K F C H R ODA OUTDOOR ANTICIPATOR -- OFT OUTDOOR FAN THERMOSTAT THERMALLY R - — - rn ODS OUTDOOR TEMPERATURE SENSOR PROTECTED I ODT OUTDOOR THERMOSTAT INTERNALLY SC SWITCH OVER VALVE SOLENOID TDL DISCHARGE LINE THERMOSTAT TNS TRANSFORMER _ _ qH-P�LPCO TYPICAL AIR HANDLER --�------- ' IPC I I TYPICAL CO THERMOSTAT I ' Ie y i Y i ----+ --�Y r ' Le MOTES Iaz I , HEAT (OPTIONAL) C�-- W3 , r (REMOTE)' X2 I � I CONTROLS) i I ODT- li-a-BK---�--';�-�-; I-----BK-_J--'� -1 - ODT-A� (OPTIONAL) I (—I—� W -- I — WI , I r- pro-BK-------' � I � I -------BK----------' I L-�—� - — ---- THIS 24V - R---I�--RDO � I TO POWER SUPPLY PER LOCAL CODES ---- ®WARNING ®CAUT ION HAZARDOUS VOLTAGEI USE COPPER CONDUCTORS ONLYI DISCONNECT ALL ELECTRICAL UNIT TERMINALS ARE NOT DESIGNED POWER INCLUDING REMOTE TO ACCEPT OTHER TYPES OF CONDUCTORS, DISCONNECTS BEFORE SERVICING. Failure to do so may cause damage Failure to disconnect power to the equipment. before servicing can cause severe personal injury or death. _,,-COLOR OF WIRE BK/BL --COLOR OF HARMER BK BLACK RD RED OR ORANGE BL BLUE WH WHITE GR GREEN SR BROWN YL YELLOW PR PURPLE PN PINK LTBL LIGHT BLUE NOTES: I. IF ODT-B IS NOT USED. ADD JUMPER BETWEEN Wt a W3 AT AIR HANDLER. IF USED, ODT-B MUST BE MOUNTED REMOTE OF CONTROL BOX IN AN APPROVED WEATHER PROOF ENCLOSURE. 2. IF ODT-A IS NOT USED. ADD JUMPER BETWEEN WI S W2 AT AIR HANDLER. 3. LOW VOLTAGE 124 Vt FIELD WIRING MUST BE IS AWG MIN. FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIENNES CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 15OV-TO-GROUND ATTENTION:NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE PRINTED FROM D157362PO3 REV00 4A7A3043A-SUB-1 B-EN (yAPIngersoil Rand Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands — including Club CaO, Ingersoll Rand(D, Thermo King® and TraneO—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. �® (J? Ingersoll Rand T THERMO KING 0 TRAAAF i ngersollrand.com CST IS Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4A7A3043A-SUB-1B — EN 031VIar2017 Supersedes 4A7A3043A-SUB-1A-EN (February2017) ©2017 Ingersoll Rand I all rights reserved