Loading...
2267_001PAGE Eng¡neers I Planners I Surveyorg PACE Erìg¡neer$, lnc. | $DA 1724 ì,V. Mar¡ne V¡ev.,Drive I Suiie 140 Everett, Wash¡ngton 98201-2088 p 425.486.6533 | f425.486.6593 An Eilglnssrln0 Ssûlc6s Côilpûny ænilffi August 30,2019 City of Edmonds Attn: Jeanie McConnell 121 5th Avenue North Edmonds, WA 98020 Jenkins Lane Lot 4 - Single Family Residence #BLD2OI9O8í5 lst Review - Response to Gomments Dear Jeanie: We are pleased to resubmit the attached Site Plan set for further review and approval. These plans aresubmitted in responsetothe lstSite Plan Reviewfrom both Planning and Engineering. The following is a summary of responses to the review comments contained on the plan set and comment letters. Review comments are shown in plain text and our responses are provided in bold italics. Comments from Jeanie McCon nell (ieanie.mcconnell@edmondswa.qov) : General 1. A Stormwater Covenant is required to be recorded against the property based on the proposed stormwater facilities for the project. Please complete the covenant, including notarization and any required exhibits and submit to the city. Ensure the stormwater covenant meets Snohomish County Record Drawing requirements. The document must be complete but will not be recorded prior to permit issuance. Prior to construction final, location of facilities are to be verified (by field inspection and asbuilt) and then the covenant will be recorded. submitted by applicant. 2. Submit Side Sewer Permit Application form. submitted by applicant. Sheet 1 of 3 - BUILDING SITE PLAN 1. Note driveway surface material as either concrete or asphalt Concrete driveway noted. www.paceeng¡"s.cor11 August 30, 2019 City of Edmonds Page 2 of 5 Engineers I Planners I Surveyors www. paceengrs.com Sheet 2 of 3 - UTILITY AND TESC PLAN 1. Clarify Note 1 to state that the storm tightline shall not be connected to the footing drains any closer than 1O-ft from the foundation. Revrsed note. 2. Clarify Note 13 so it is clear the 1ft minimum cover does not apply to water and sewer. Sewer shall have 2ft of cover and water shall have 18" cover, regardless of location being in paved or landscaped area. Revrsed note. 3. Orange protective barrier fencing shall be placed around the area of the drywell locations to protect the area from compaction. Show on plans. Added to construction sequence and shown on utility plan. Sheet3of3-PLANNOTES 1. Revise General Note 1 to reflect the current version of the WSDOTiAPWA specs Revised note. 2. Remove General Note #19. lt is not applicable to this project. Removed note. Gomments from Stormwater Ensineer. Zack Richardson (zaçkarv.lichardson@edmo-nds.wa.aov[ 1. lt appears the proposal for this lot has increased the impervious area and decreased the drywall volume since the previous plat approval; the minimum value now used (by simplified sizing) meets code but represents a revision from the previously approved drainage plan which requires additional attention [Comment truncated for brevity] (a) Simplified sizing to meet MR #5 does not ensure that a regular overflow will not occur here; for this reason these systems require a piped overflow. lf system remains as currently designed, update plans to provide a piped overflow connection to the city system. (b) Alternatively, the applicant can demonstrate that the system achieves 1o0o/o infiltration, typically requiring a \AA/r/HM model with the field measured infiltration rate. Design calculations have been provided as an attachment to this letter, to satisfy alternative (b) above. The calculations demonstrate 100% infiltration of roof runoff. PACE Àr É.îúGe¿? tù¡:r¡r lúrt31r !lrBfi August 30,2019 City of Edmonds Page 3 of 5 Engineers I Planners I Surveyors !v\¡v\,v. pACeeng rS. COm 2. Show protective construction fencing around the drywell areas. (a) lf fencing cannot be feasibly located during construction, add notes to over excavate and obtain geotech approval of the subgrade prior to backfilling drywells. Called out in construction sequence and added to utility plan. 3. Provide detail or specification enough for contractor to install soils meeting the requirements of BMP T5.13 (City detail SD-642). Detail SD-642 has been added to sheet 4 of 4. 4. Update drywell details to be SD-638 or update plan details to provide more of the required and shown elements from the City version: (a) Update "marked center" to provide an observation pipe to the bottom of the facility with detail as/where needed for construction. (b) Extend distribution pipe through entire width of drywell and bring to surface with clean-out with detail as/where needed for construction. (c) Calloutishow a push-on tee or downturned elbow in the yard drain upstream of the drywells with detail as/where needed for construction. (d) ldentify 12" minimum cover depth, provide a bottom of rock elevation, and ensure the two are consistent with proposed finish grade. (e) ldentify the top and bottom of rock elevation for each drywell. The requested revisions have been made. 5. Show dimensions between the drywell and property lines (min 5') Dimensions have heen added. 6. Provide a minimum footing drain elevation to ensure perforated portions of the footing drains remain a minimum of 6" above top of rock for the infiltration facility, or revise footing drain connection to be un effected by infiltration storage. Minimum footing drain elevation is specífied on Sheet 2 of 4 (left side of sheet). The attached drainage calculations demonstrate that the sfage depth in the infiltration galleries is not likely to reach the top of the provided galleries. 7. There do not appear to be any collection point for pervious areas and the grading plan may direct more runoff toward the adjacent road and wall to the west; update plans and/or provide response to address concern as appropriate (infiltrates before it can reach edge, revise grading to retain runoff, or add collection point and adjust drywell). The lot grading contours have been adjusted slightly for clarification. Most of the peruious area is intended fo s/ope toward the yard drain at the southwest corner of the lot. A note has been added fo Sfieef 2 of 4 for additional clarification. Outwash soil ¡i É .lr'¿{:i{ óifr ì, ùr tüiÈ*rt !f ¡Bq August 30, 2019 City of Edmonds Page 4 of 5 a underlies the site, and the topsoil specifîcation provided on Sheef 4 of 4, so tnosf runoff is likely to infiltrate before reaching the area drain. Comments from Planner. Michele Q. Szafran (qichele..g.?3ffan@edmpndswa.qpv)i / ^:1- ñl---l. ùtle rtaf r ¡ Please provide a scale on the site plan Scale has been added . Please verify the height elevation for point B This elevation has been verified against the topographic survey and is listed correctly. 2. Elevation Plans: Please verify that the elevations provided are correct. The south elevation does not appear to match the provided floor plan. addressed a Please label the elevation views accurately addressed 3. Datum Point: A datum point is used to establish a starting mark to compute grade elevation of the designated four corners for the building height calculations in order to verify zoning height compliance. The datum point must be a permanent point of reference, such as the top of a manhole cover, fire hydrant, water meter, or street monument. The datum point is also used to verify the height of the structure during the height inspection or survey if required. A datum point has been provided at the intersection of 7th and 13th Way SW however you may want to pick a datum point which is closer. Comment is noted, and will be forwarded to the proiect surveyor. a Engineers I Planners I Surveyors ww\ /. paceengfs.com PACE Áa L¡l{¡8rii¡! Srrw¡! t¿qñ¡t lfÐæ '_ f" ':':: . a.: :-?, - .. ,!.': j : August 30,2019 of Edmonds Sincerely, PACE Engineers, lnc. This concludes our response to the previous review'lqffiEn,-Please (425) 486-6533, or if I can provide anything further. "',.. /¿,4ø,Ø Kenneth J. Mclntyre, PE Project Manager eblffirgrffitm@ R:\projects\1 86 (gchelbârger)\o03-1 7 (Jenkins Lane)\AcJrnin\Correspondence\Site Plans\2o 1 g-08-28-LOT 4*1 st Response.docx ntr