2020-0241 phaysith Page 1 of 1 DATE: 3/5/2020 TO: Applicant: BRYAN PHAYSITH Owner: ACJ HOLDINGS LLC FROM: DONOVAN AKAU RE: Plan Check: BLD2020-0241 Project Address: 9327 217TH ST SW Project: ACJ HOLDINGS/PHAYSITH- INTERIOR REMODEL, p&m INCL During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. Please submit to a Permit Coordinator 2 sets of revised plans/documents, including a written response letter that is in itemized letter format. Indicate where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans. Upon receipt the re-submittal will be routed for review(s). Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. General: 1. Please identify where the Whole House Mechanical ventilation is to be located and how this will be achieved on the set of plans. It is apparent that a continuous fan rating 50 CFM is to be installed in the Laundry room. There is concern that the fan along with other mechanical appliances in that room may affect the proper Combustion air requirements. Table 1507.3.3 (1) and 1507.3.3(2), 2015 IRC. 2. Please provide a cross section detail from the foundation to the roof/attic showing the R- values that meets the 2015 WSEC. Sheet 2: 3. Provide a fastening schedule as how the (4) 1.75” x 20” LVL 2.0E are to be connected to each other on the set of plans for this project. City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 2 4. Provide a detail for the +40” guard rail located at the covered porch at the main entrance. Section R312, 2015 IRC Sheet 3: 5. It appears that the opening at the existing bearing wall has been enlarged for the door way to the Laundry room. Please provide a detail(s) for the construction of the new opening or provide a detail(s)/calculations from the EOR as to the construction of the new opening that will support the loads that are imposed on the opening and how it will be supported. 6. It is apparent that a new opening has been installed in the existing bearing wall for the new walk in closet. Please provide a detail(s) for the construction of the new opening or provide a detail(s)/calculations from the EOR as to the construction of the new opening that will support the loads that are imposed on the opening and how it will be supported. 7. It appears that laundry area has been created in the basement. Please clarify/correct this on the plans. 8. Please indicate on the plans the appliances that are to be gas or electric. Should these mechanical appliance be gas please provide a detail as to how the outdoor Combustion Air requirements will be achieved. Section G2407.6 (304.6) 2015 IRC 9. The fan that has been provided in the laundry that may be used for the whole house ventilation is insufficient per table 1507.3.3(1) or if intermittent please provide the factors and the size of the fan that is/may be used for the whole house mechanical ventilation. Please keep in mind that if this fan is a component of the whole house ventilation that it may affect the gas fueled appliances. See table 1507.3.3(2) Sheet 4: 10. It appears that there are conflicting information that is being provided from the table “Ventilation for all group private dwelling single and multiple” and the verbiage that is being used for the whole house ventilation. Please clarify this on the plans. 11. It appears that the appliances are gas, based on the Energy credits that have been chosen for this project. Please indicate on the plans the appliances that are gas/electric. Should these mechanical appliance be gas, please provide a detail as to how the outdoor Combustion Air requirements will be achieved in the laundry/mechanical room or correct the Energy credits chosen and make corrections on the plans. Section G2407.6 (304.6) 2015 IRC Thank you, DONOVAN AKAU City of Edmonds (425) 771-0220