FIR2020-0104_Fire_Alarm_Equipment_Specification_Sheets_11.30.2020_1.13.20_PMLOW VOLTAGE SYSTEMS BY
roomm
PROTECTION & COMMUNICATIONS INC.
Fire Alarm System -
Product Data & Battery Calculations -
for
EDMONDS
WACHT
326 ADMIRAL WAY
EDMONDS WA 98020
Protection & Communications, Inc.
220 RAILROAD AVE
EDMONDS WA 98020
Phone: 425.774.9099
Fax: 425.774.6317
!mr*AE
of SECURITY
CORPORATION
I VOVATI0u
7707 Fire Subscribers
IntelliNet toll
Introducing a Newer,
Smarter Alarm
Communications Platform
New Feature Highlights
• Leverages state of the art technology
• Applies advanced security protection
• Offers flexible power and configuration options
• Engineered for backward compatibility with legacy systems
• Enables future ready capabilities
• Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD
display, and Menu/Silence button
• Improves functionality with an adaptive Graphic User Interface (GUI) for programming via
smartphones, tablet and PCs
• Plus many more...
aes-corp.com
L'RJ v
NFPA LISTED
Key Benefits that Make 2.0 the Best Alarm Monitoring Solution Ever
• Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private
licensed wireless networks
• Protects subscriber units against unauthorized access and rogue activity with a password protected
Dealer Code
• Makes programming and streamlined troubleshooting easy with user friendly interface
• Adds integrated supervision of AES-IntelliPro full data module
• Provides versatile power options:
(1) Direct from the Fire Alarm Control Panel (FACP) without requiring an electrician onsite and without
Subscriber backup battery
(2) Directly from the FACP with Subscriber backup battery; or
(3) Traditional installation with plug in Class 2 low power transformer
• Allows for enhancement upgrades and an expanded number of new features to be added easily with
highly flexible and scalable alarm communications infrastructure
• Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and
UL standards
Enhanced Wireless Fire Alarm Monitoring
Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation
universal wireless communicators that provide advanced security protection for any new or existing alarm
monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data
module option, they are the ideal drop -in replacement for Plain Old Telephone Service (POTS) lines.
The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides
an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units
via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or
having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation.
IntelliNet 2.0 Private Wireless Mesh Radio Network
D) Burglary D
Subscriber-----""-----�
hom B
/ 1
-0 C
/
/ 0 �� 1 N
B) Fire / / / N I
Subscriber / t 1 ----- --
/ 1 `1 1 AES-N—ark Mamyement System
D
B — — — — — — — Rrlmery AfS-Mu1rlNtt Receiver
I
1
A) Alarm
Panel 1 Secondary AES-MultiNer Receiver
� 1
� 1 1
B ey/ ' B C Alarm Automation
A � -------------
QIPLinks
Customer Location Mesh Radio Technology Central Monitoring Station
Alarm Panel & AES Subscriber Multi -path AES.IntelliNete Network Primary & Secondary AES.MultiNet System
sends critical event signal delivers alarm signals wa smart routing, receives transmission in 1-3 seconds
The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity,
POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add -on accessory board.
AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time.
An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A
laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers
will not work with 2.0 units. The forward compatible design allows for feature add-ons, engineered to adapt
seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for
faster installation time.
The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians
to get in, out, and on to the next install.
Visit our Fire Marshal Resources web page for official NFPA and UL Listings:
http://aes-corp.com/products/fire/fire-marshal-resources/
How to Order
7707 Fire
InteffiNet 2.0 Fire Subscribers
2.0 PREMIUM (UL & ULC Listed, Available Now!)
IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones, with integrated onboard
7707P-88
Local Annunciator, Red Enclosure
IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794A AES-IntelliPro
7707P-88-ULP
and integrated onboard Local Annunciator, Red Enclosure
IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones, with integrated onboard
7707P-44
Local Annunciator, Red Enclosure
IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones with 7794A AES-IntelliPro
7707P-44-ULP
and integrated onboard Local Annunciator, Red Enclosure
2.0 FEATURE ADD (Pending UL Review)
IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies
7707P-88-M
(MCT), Red Enclosure
IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated
7707P-88-ULP-M
onboard Local Annunciator plus MCT, Red Enclosure
IntelliNet 2.0 Fire Subscriber, 4 Zone with Multiple Communication Technologies
7707P-44-M
(MCT), Red Enclosure
IntelliNet 2.0 Fire Subscriber, 4 Zone with 7794A AES-IntelliPro, and integrated
7707P-44-ULP M
onboard Local Annunciator plus MCT, Red Enclosure
7707M-UPG
IntelliNet 2.0 Fire MCT Software Upgrade
2.0 ACCESSORIES
Standalone AES-IntelliPro Fire full data module add -on accessory board with
7794A
firmware for new IntelliNet 2.0 units only, cannot be used in legacy units
77-WiFi
AES certified WiFi adapter
Legacy. .-
7706-ULF
Integrated Fire Monitoring System, Red Enclosure
Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module,
7788F-ULP-P
7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure
Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro,
7788F-ULP
Red Enclosure
7788F
Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure
Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module,
7744F-ULP-P
7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure
Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro,
7744F-ULP
Red Enclosure
Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones,
7744F
Red Enclosure
LEGACY ACCESSORIES
Standalone AES-IntelliPro Fire full data module add -on accessory board for legacy
7794
units only, please see 7794A above for IntelliNet 2.0 version
Technical Specifications
7707 Fire
DIMENSIONS
13"H x 8.5"W x 4.5"D
(33cmH x 21.5cmW x 11.4cmD)
WEIGHT
5.8 Ibs (2.6 kilograms)
excluding battery
13 Ibs (5.9 kilograms) with
10 Ah battery
RADIO FREQUENCY
Standard Frequency Range:
450-470 MHz
Contact AES for other UHF
and VHF frequencies
ANTENNA
2.5 dB tamper resistant antenna
included, mounts on enclosure
Optional remote mounting
antenna available
POWER INPUT
AC SOURCES
Class 2 transformer
40VA, 120V AC primary
ELK ELK-TRG1640, MG Electronic
Sales MGT1640, and AES 1640 are
UL Listed for use (not included)
1.75A, maximum input
current value
16.5V AC, nominal output value
DC SOURCES
External regulated power supply,
24V DC, rechargeable backup
battery in Subscriber
1.3A, input current
Regulated power supply from FACP
AUX power, 24V DC, UL Listed FACP
with backup battery in FACP
1.3A, input current
Contact Us
BACKUP BATTERY
10-12 Ah, UL recognized lead acid
gel cell, size based on subscriber
configuration
ALARM SIGNAL INPUTS/ZONES
8 individually programmable
E.O.L. type zone inputs
4+4: 4 reverse polarity input and
4 individually programmable
E.O.L. type zone inputs
Optional 7794A AES-InttelliPro for
full data via Contact ID, Pulse,
Modem Ile and Modem IIla2
UL LISTINGS
UL 864 loth Edition
Standard for Control Units and
Accessories for Fire Alarm Systems
ULC S559-04 1st Edition
Equipment for Fire Signal
Receiving Centres and Systems
TROUBLE OUTPUT—ACK
DELAY/ANTENNA CUT
Form C relay, fail secure, rated 24V
DC 1A resistive
RESET BUTTON
Located on main circuit board
OPERATING TEMPERATURE
32 to 120OF (0 to 49°C)
STORAGE TEMPERATURE
14 to 140°F (-10 to 60°C)
RELATIVE HUMIDITY
0 to 93%, non -condensing
RECHARGE CAPABILITY
Will charge 12V battery size
from 10-12 Ah
PORTS
Ethernet for configuration and
communication
USB access for
software upgrade
REMOTE ANNUNCIATOR
AES Model 7740
Remote Annunciator, supervised
COMPATIBLE RECEIVERS
7705i AES-MultiNet Receiver
CONFIGURATION INTERFACE
Web browser capable device
accessible via smartphone, tablet,
laptop, or PC
CURRENT CONSUMPTION
Standby with charged backup
battery: 175 mA
Standby + charging backup battery:
200 mA
Transmitting: 1.2 A (typical
transmission is 1/3 second length)
POWER OUTPUT
2 or 5 Watts
Factory set
ENCLOSURE MATERIAL
Steel with paint finish
FINISH COLOR
Red
VISUAL INDICATORS
Front panel LCD
(2 x 20 alphanumeric character
backlit display)
Power and Trouble LEDs
(ALM Trouble Tx, Rx, WA)
For pricing and availability or to learn more about IntelliNet 2.0, please call your local
AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com.