occupant loadCEILING PLAN NOTES & FF&E NOTES
UNLESS OTHERWISE INDICATED:
1) CONTRACTOR SHALL CONFIRM DIMENSIONS, LOCATIONS, WEIGHTS, SUPPORT -
REQUIREMENTS, AND UTILITY REQUIREMENTS OF ALL OWNER -FURNISHED EQUIPMENT WITH
OWNER AND EQUIPMENTS SUPPLIER, PRIOR TO INSTALLATION.
2) WHERE NO MOUNTING HEIGHT IS INDICATED OR SCHEDULED FOR FIXTURES, EQUIPMENT,
ACCESSORIES, COORDINATE MOUNTING HEIGHT WITH ARCHITECT PRIOR TO INSTALLATION.
3) CEILING GRIDS ARE DRAWN CENTERED IN THE ROOM AND SHALL BE INSTALLED
CENTERED WITHIN THE ROOM AS SHOWN.
4) CEILING -MOUNTED LIGHTS, SPEAKERS, DIFFUSERS, GRILLES, AIR TERMINALS, SPRINKLER
HEADS, AND SIMILAR ARE DRAWN CENTERED IN CEILING PANELS OR CENTERED IN ROOM.
THESE DEVICES SHALL BE INSTALLED CENTERED WITHIN THE CEILING PANELS AND WITHIN
THE ROOMS AS SHOWN.
5) PROVIDE AND INSTALL EMERGENCY EXIT SIGNS, HORNS, AND EMERGENCY LIGHTING PER
CODE. VERIFY LOCATIONS WITH DEISGNER. USE CEILING MOUNTED WHITE FIRE ALARMS IF
POSSIBLE.
6) ELECTRICIAN TO VERIFY DAYLIGHT ZONES AND INSTALL DAYLIGHT CONTROLS PER CODE.
7) WHEN APPLICABLE, PROVIDE AND INSTALL OCCUPANCY SENSORS WITH WALL MOUNTED
MANUAL SWITCHES CAPABLE OF AUTOMATICALLY TURNING OFF ALL THE LIGHTS IN THE
AREA, NO MORE THAN 30 MINUTES AFTER THE AREA HAS BEEN VACATED.
8) ALL LIGHTING & CONTROLS TO COMPLY WITH THE 2015 WASHINGTON STATE ENERGY
CODE SECTION C405.2.1 THROUGH C405.2.5.
GENERAL DAYLIGHTING ZONE NOTES
ALL DAYLIGHTED ZONES AND DAYLIGHT ZONE CONTROLS SHALL COMPLY WITH THE 2015
WASHINGTON STATE ENERGY CODE.
PRIMARY DAYLIGHT ZONE: EXTERIOR WINDOW HEAD HIGHT X WINDOW WIDTH + 2' ON
EITHER SIDE. SECONDARY DAYLIGHT ZONE: AREA EQUAL IN SIZE TO THE PRIMARY ZONE.
AUTOMATIC DAYLIGHT SENSING CONTROLS SHALL BE CAPABLE OF REDUCING THE LIGHT
OUTPUT OF THE CONTROLLED LUMINAIRES WHILE MAINTAINING A UNIFORM LEVEL OF
ILLUMINANCE BY CONTINUOUS DIMMING TO LESS THAN 15% OF RATED POWER AT MAXIMUM
LIGHT OUTPUT.
DAYLIGHT SENSING CONTROLS SHALL CONTROL ONLY LUMINAIRES WITHIN DAYLIGHTED
AREA.
AUTOMATIC DAYLIGHT SENSING CONTROLS SHALL INCORPORATE TIME -DELAY CIRCUITS TO
PREVENT CYCLING OF LIGHT LEVEL CHANGES OF LESS THAN THREE MINUTES. SEE CEILING
PLAN FOR ROOMS/AREAS WHERE OCCUPANCY SENSORS ARE TO BE LOCATED.
EXCEPTIONS: SPACES WHERE PATIENT CARE IS DIRECTLY PROVIDED (2015 WSEC SECTION
C405.2.2 EXCEPTION #2).
LIGHTING LEGEND
RECESSED 6" CAN LIGHT - LED DOWNLIGHT
A
NORA - NCH-630-12-LE4
16 WATTS QTY = 2
RECESSED 6" CAN LIGHT WITH WALL WASH
B
G
KIT - SEE RECESSED CAN LIGHT FOR INFO
16 WATTS QTY =1
2' X 2' LED - ZR22 - 2X2 LED TROFFER
C
CREE TRUEWHITE
32 WATTS QTY =14
2' X 4' LED - ZR24 - 2X4 LED TROFFER
D
CREE TRUEWHITE
40 WATTS QTY =10
VANITY LIGHT FIXTURE
E
NUVO LIGHTING - NUVO 62-1102
26 WATTS QTY =1
ECHO PENDANT FIXTURE
F
TECH LIGHTING 70OTDECPSCS
22 WATTS QTY = 2
EXIT LED SIGNS
G
®
COMPASS - CELS1 GNE & CELS2RNE
3.72 WATTS QTY = 2
NEW ACP GRID CEILING
NEW GWB CEILING OR SOFFIT
OC
LIGHTING TO BE ON OCCUPANCY SENSORS
AUTOMATIC HORIZONTAL SHADE SYSTEM
EXISTING SKYLITE - PATCH
AND PAINT EXISTING GWB
O2 CEILING PLAN_ - LEVEL 2
1/4" =1'-0"
OC
OFF CE
20 1
p OC
AC -1
8'-0 AFF
n
C
D
EXA
2 0
0 #2
7
OC
AC
8'-0
-1
AFF
D
TIDES OC
C
ACP-1
-0"AF
C
C
C
C
AFF BRI
2022
ACP-1
8'-0"Af
OFFICE
220
p OC
A P-1
8'- "AFF
D
E
2
M #3
18
OC
AC
8'-0"AFF
-1
D
D
EXAM
L2C
#1
16
OC
ZD:]
A P-1
8'- 0wAFF
C
r
\�
A
0
I
f3` GWB
- - - 7'-6"AFF
-
i
G
C
ACP-1
-0"AI
OC
D
ACPA
8'-0 AFF
RECE TION
.2012
p OC
AC -1
8'- 0 AFF
0 0
4 -
C
FLOOR PLAN - LEVEL 2
1/4" = V-0"
1
N
0 19
ALI
0
U?
ao
STAFF BREAK
2022
140 sf
- ALIGN -
0
MA WORK
12 2 114
47.01 69 sf `-
r
RECEPTION
/n A7.01 2012
6 54 sf i ao
Q o
i
;'17J
...._.._.....
9
9
8
t 425.778.1530 21911 76th Ave W. Suite 210
f 425.774.7803 Edmonds WA 98026
info@tg barchitects-com
www.tgbarchitects.com
3626 REGISTERED
%NE
ITECT
G Y
STATE OF WASHINGTON
SWEDISH
SURGERY
SPECIALTY CLINIC
Edmonds Medical Plaza
21616 76th Avenue W, Suite 201A
Edmonds, WA 98026
FLOOR PLAN &
CEILING PLAN
RECEIVED
MAR 21 2019
toeiaOPMf`NT SERVICES CTR.
CITY OF EDMONDS
ISSUANCE
No. Description Date
1 PERMIT SET 03/21/19
PROJECT INFORMATION
PROJECT NUMBER: 19007
PROJECT LEAD: AB
DRAWN BY: AB
SHEET NO
A2ml 1