occupant loadCEILING PLAN NOTES & FF&E NOTES UNLESS OTHERWISE INDICATED: 1) CONTRACTOR SHALL CONFIRM DIMENSIONS, LOCATIONS, WEIGHTS, SUPPORT - REQUIREMENTS, AND UTILITY REQUIREMENTS OF ALL OWNER -FURNISHED EQUIPMENT WITH OWNER AND EQUIPMENTS SUPPLIER, PRIOR TO INSTALLATION. 2) WHERE NO MOUNTING HEIGHT IS INDICATED OR SCHEDULED FOR FIXTURES, EQUIPMENT, ACCESSORIES, COORDINATE MOUNTING HEIGHT WITH ARCHITECT PRIOR TO INSTALLATION. 3) CEILING GRIDS ARE DRAWN CENTERED IN THE ROOM AND SHALL BE INSTALLED CENTERED WITHIN THE ROOM AS SHOWN. 4) CEILING -MOUNTED LIGHTS, SPEAKERS, DIFFUSERS, GRILLES, AIR TERMINALS, SPRINKLER HEADS, AND SIMILAR ARE DRAWN CENTERED IN CEILING PANELS OR CENTERED IN ROOM. THESE DEVICES SHALL BE INSTALLED CENTERED WITHIN THE CEILING PANELS AND WITHIN THE ROOMS AS SHOWN. 5) PROVIDE AND INSTALL EMERGENCY EXIT SIGNS, HORNS, AND EMERGENCY LIGHTING PER CODE. VERIFY LOCATIONS WITH DEISGNER. USE CEILING MOUNTED WHITE FIRE ALARMS IF POSSIBLE. 6) ELECTRICIAN TO VERIFY DAYLIGHT ZONES AND INSTALL DAYLIGHT CONTROLS PER CODE. 7) WHEN APPLICABLE, PROVIDE AND INSTALL OCCUPANCY SENSORS WITH WALL MOUNTED MANUAL SWITCHES CAPABLE OF AUTOMATICALLY TURNING OFF ALL THE LIGHTS IN THE AREA, NO MORE THAN 30 MINUTES AFTER THE AREA HAS BEEN VACATED. 8) ALL LIGHTING & CONTROLS TO COMPLY WITH THE 2015 WASHINGTON STATE ENERGY CODE SECTION C405.2.1 THROUGH C405.2.5. GENERAL DAYLIGHTING ZONE NOTES ALL DAYLIGHTED ZONES AND DAYLIGHT ZONE CONTROLS SHALL COMPLY WITH THE 2015 WASHINGTON STATE ENERGY CODE. PRIMARY DAYLIGHT ZONE: EXTERIOR WINDOW HEAD HIGHT X WINDOW WIDTH + 2' ON EITHER SIDE. SECONDARY DAYLIGHT ZONE: AREA EQUAL IN SIZE TO THE PRIMARY ZONE. AUTOMATIC DAYLIGHT SENSING CONTROLS SHALL BE CAPABLE OF REDUCING THE LIGHT OUTPUT OF THE CONTROLLED LUMINAIRES WHILE MAINTAINING A UNIFORM LEVEL OF ILLUMINANCE BY CONTINUOUS DIMMING TO LESS THAN 15% OF RATED POWER AT MAXIMUM LIGHT OUTPUT. DAYLIGHT SENSING CONTROLS SHALL CONTROL ONLY LUMINAIRES WITHIN DAYLIGHTED AREA. AUTOMATIC DAYLIGHT SENSING CONTROLS SHALL INCORPORATE TIME -DELAY CIRCUITS TO PREVENT CYCLING OF LIGHT LEVEL CHANGES OF LESS THAN THREE MINUTES. SEE CEILING PLAN FOR ROOMS/AREAS WHERE OCCUPANCY SENSORS ARE TO BE LOCATED. EXCEPTIONS: SPACES WHERE PATIENT CARE IS DIRECTLY PROVIDED (2015 WSEC SECTION C405.2.2 EXCEPTION #2). LIGHTING LEGEND RECESSED 6" CAN LIGHT - LED DOWNLIGHT A NORA - NCH-630-12-LE4 16 WATTS QTY = 2 RECESSED 6" CAN LIGHT WITH WALL WASH B G KIT - SEE RECESSED CAN LIGHT FOR INFO 16 WATTS QTY =1 2' X 2' LED - ZR22 - 2X2 LED TROFFER C CREE TRUEWHITE 32 WATTS QTY =14 2' X 4' LED - ZR24 - 2X4 LED TROFFER D CREE TRUEWHITE 40 WATTS QTY =10 VANITY LIGHT FIXTURE E NUVO LIGHTING - NUVO 62-1102 26 WATTS QTY =1 ECHO PENDANT FIXTURE F TECH LIGHTING 70OTDECPSCS 22 WATTS QTY = 2 EXIT LED SIGNS G ® COMPASS - CELS1 GNE & CELS2RNE 3.72 WATTS QTY = 2 NEW ACP GRID CEILING NEW GWB CEILING OR SOFFIT OC LIGHTING TO BE ON OCCUPANCY SENSORS AUTOMATIC HORIZONTAL SHADE SYSTEM EXISTING SKYLITE - PATCH AND PAINT EXISTING GWB O2 CEILING PLAN_ - LEVEL 2 1/4" =1'-0" OC OFF CE 20 1 p OC AC -1 8'-0 AFF n C D EXA 2 0 0 #2 7 OC AC 8'-0 -1 AFF D TIDES OC C ACP-1 -0"AF C C C C AFF BRI 2022 ACP-1 8'-0"Af OFFICE 220 p OC A P-1 8'- "AFF D E 2 M #3 18 OC AC 8'-0"AFF -1 D D EXAM L2C #1 16 OC ZD:] A P-1 8'- 0wAFF C r \� A 0 I f3` GWB - - - 7'-6"AFF - i G C ACP-1 -0"AI OC D ACPA 8'-0 AFF RECE TION .2012 p OC AC -1 8'- 0 AFF 0 0 4 - C FLOOR PLAN - LEVEL 2 1/4" = V-0" 1 N 0 19 ALI 0 U? ao STAFF BREAK 2022 140 sf - ALIGN - 0 MA WORK 12 2 114 47.01 69 sf `- r RECEPTION /n A7.01 2012 6 54 sf i ao Q o i ;'17J ...._.._..... 9 9 8 t 425.778.1530 21911 76th Ave W. Suite 210 f 425.774.7803 Edmonds WA 98026 info@tg barchitects-com www.tgbarchitects.com 3626 REGISTERED %NE ITECT G Y STATE OF WASHINGTON SWEDISH SURGERY SPECIALTY CLINIC Edmonds Medical Plaza 21616 76th Avenue W, Suite 201A Edmonds, WA 98026 FLOOR PLAN & CEILING PLAN RECEIVED MAR 21 2019 toeiaOPMf`NT SERVICES CTR. CITY OF EDMONDS ISSUANCE No. Description Date 1 PERMIT SET 03/21/19 PROJECT INFORMATION PROJECT NUMBER: 19007 PROJECT LEAD: AB DRAWN BY: AB SHEET NO A2ml 1