2020-0140 Grabicki DATE: February 24, 2020 TO: Thomas Grabocki tomgrabicki@comcast.net FROM: Donovan Akau, Plans Examiner RE: Plan Check: BLD2020-0140 Project Address: 411 6th Avenue South Scope: New addition of Bedroom, Bathroom and Deck Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. General: 1. Please provide a water fixture count for the existing dwelling, so that I may complete a total WSFU count. This ids to determine the proper sizing of the water meter for the dwelling. 2. It is apparent that for the WSEC 1a has been chosen for an Energy credit which requires a floor R-38 value. The plans indicate an R-30. Please make corrections on the plans. 3. Provide indicate on the plans a mechanical fan and its CFM rating for the ventilation of the new bathroom. See Table M1507.4. 4. Please provide elevations and clearances for the ventilation of the plumbing for this project. It appears that there are existing openings that will be taken into consideration for the vent pipes. Please see UPC sections 906.0, 906.1 and 906.2 requirements. City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 3 5. On the site plan there is an indication of a new deck that is part of this project. Please clarify or provide details as to construction of the new deck. MyBuildingPermit.com has a great tip sheet for decks. 6. Please provide fastening details for the Paralam that is being lag bolted to existing rim on the plans. 7. It is apparent that a floor truss joist is being used for this project. Please provide the Engineer’s calculations/design for this floor system. 8. Indicate on the plans how the ventilation will be maintained for the existing crawlspace with the new crawlspace that is being created for the new addition, also indicate the access for the crawlspace for the new addition. Upon review of the resubmitted documents, additional comments may be generated. Sincerely, Donovan Akau Page 3 of 3