Loading...
ENG2019-0342RIGHT OF WAY EUC PERMIT PERMIT NUMBER City of Edmonds 98020 ENG2019-03,14 www.cityofedmonds.gov Description: Comcast bore from pole located between houses 8727 and 17512 ISSUED: 03/19/2020 Address: 17511 TALBOT RD EDMONDS WA 98026-5059 EXPIRES: 09/21/2020 rmit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 00594400005300 i NAME TYPE NAME ADDRESS PHONE APPLICANT COMCAST 1525 75TH ST SW, EVERETT WA 98203 (425)921-8201 CONTRACTOR Prince Telecom 3527 121st ST SW, Lynnwood WA 98087 (425)353-2078 OWNER DAVID 0 EARLING 17511 TALBOT RD, EDMONDS WA 98026-5059 FEE INFORMATION DESCRIPTION AMOUNT PAID ENGINEERING INSPECTION FEE $100.00 RIGHT OF WAY MINOR - EUC PERMIT FEE $100.00 X-TECHNOLOGY FEE $35.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 1• Ma dutga 3/19/20 RELEASED BY DATE Printed: Thursday, March 19, 2020 10:39:24 AM 1 of 2 -1RRRTF WAY EUC PERMIT City of • • • •:• • ENG2019-034. ., CONDITIONS CONDITION TYPE Alert Affected Properties Alert affected residents and/or businesses prior to work start. Bore Crossings Verify clear bore crossings Conform to approved plans Conform to approved working drawings and Traffic Control plan. Damage to Frontage Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per Improvements City standards that is caused by or occurs during the permitted project. ESC Required Maintain erosion & sedimentation control. Keep street clean. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and Hold Harmless agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance of this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance not limit in any way the City's ability to enforce any ordinance provision. Inspections Call for required inspections as noted. Landscape Restoration Restore Landscape to like or better conditions. ROW Restoration Restore ROW to City standards Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on Sounds/Noise weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. Traffic Control Handout Traffic Control per approved plan and MUTCD. Refer to City of Edmonds traffic control requirements. Underground Utility Locates Call for locates of underground utilities prior to any excavation. Utility Patch Restoration Utility patch restoration to be in accordance with Edmonds Standard detail E2.3 0 a • 19 INSPECTION TYPE DATE RESULT NOTES COMPLETE E-7 RESTOR LIMITS X-2 ENGINEERING FINAL" Printed: Thursday, March 19, 2020 10:39:24 AM 2 of 2 OV E c)ti10 ROW PERMIT NO.: ENG 2020-0342 ISSUE DATE: 3/19/20 RIGHT-OF-WAY CONSTRUCTION PERMIT APPLICATION PROJECT NAME: C"w1 aY'V .ice aG G bl'( CONTRACTOR• ' p, ,ICY., .Te.1�_�o�Y� Mailing Address: t� t2p-lo� �y �T P�4�g , �� h.��cv State License #: ;- M 1�Q. L t".J City Business License #: CONTACT:. V r.Yl c 'Z_ Phone #: Fax #: Email # v.•r u.1J- __y1c-2 4@ C� t ifYlllcS� Z ' 17Eiability Insurance Bonded ADDRESS OR INTERSECTION OF CONSTRUCTION: R5 ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: Commercial ❑ Multi -Family Subdivision ❑ Single Family BEUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit? City Project ❑ Other ❑ Yes ❑ No Traffic Control (Only) ANY ASSOCIATED PERMITS? BLD# ENG# ***Refer to approved site plan for updated scope of work.*** L e l .. r rvl ;� VYu%r �Uc \Giv_. �,;�'•�= ✓1 DESCRIPTION OF PROPOSED WORK (Be Specific) : ErA �nq AC1Qp U�-p 6AV- -9,w+ CMCA Ma rysi-S 1 albo "Iyo ikg wit 1 bore q -A- 51,t� Grc�S-5 -k1 hs�_ view -Yx se 1-1511 WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES F1 NO ff Year: PAVEMENT CUT: [33Yes ❑ No If yes, indicate size of cut: 19 x C CONCRETE CUT: ❑ Yes ❑ No If yes, indicate sue of cut: x RIGHT-OF-WAY AREA CLOSURE TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF SF Alley 72 Hrs + LF I X LF SF Parking 72 Hrs + LF X LF SF APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS. Indemnity. The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the a to be valid. 1 SIGNATURE DATE V h cf I / g Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE SIGN SPACING = (1) MINIMUM SHOULDER TAPER LENGTH = U3 (feet) RURAL ROADS & URBAN ARTEWALS 35 140 kFII 35''. I_C2_),ISHDllLDFR PGSl6d Speed (mph} RURAL ROADS, URBAN ARTERIALS, _ RF;SB &VM & BUSINESS M7RIC15 251 3 7H * 25 Sb 35 1 40 I_a5 50 55 BO 70 URBAN STREETS 25 MPI3 OR LESS IW0 [q (1) ALL. SPACING MAY BE ADJUSTED TO ACWMMODATE B l�� I +—�— _ INIEtSECUIUNS Alfa DRN61AYS, nR -- 90 BO - - {ZJ THIS SPACING MAY HE RGOUrM IN URBAN AR AS TO FIT "" "-��—�-� - ROADWAY CONDMONS. USE A 3 DEVICE. TAPER FOR SHOULDERS LESS THEN B' Applicant shall repair/replace all damage to Owner/contractor is responsible utilities or frontage improvements to City for erosion control and drainage. right-of-way per city standards that is caused or occurs during the permitted project. _ _ — .- — — — _ — _ _ — _ _ _ -- ? q q X i 4B• qB- ROAOAUIC \ (/ SHOULDER AHEAD \ VRiRK / 4B• � /4B• YtLO-1 W21.5 P � I.oJ :ice 4 Ln 1 a I Use one lane closure TCP (attached) as necessary. Any cuts in Talbot Rd shall require BUFFER DATA LONGITUDINAL BUFFER SPACE B SPEED (MPt1) 25 , 34 35 40 45 l 50 55 60 1 65 1 73 LENGTH ((eel I 155 1 200 250 305 360 I 425 1 495 570 1 545 1 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT HOST VEHICLE VNBGHT I 9.900 TO 22,000 Iba. > 22.005 Iba. < 45 MPH 45-55 MPH > 55 MPM < 45 MPH 45.55 MPH > 55 MPH 100' I 123' 172' I 74' 100' I 150' PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED CHANNEWATION DEVICE MPH SPA C)(„ (reett40 q}y�� 20 TVCRK AREA ENGINEERING DIVISION APPROVED AS NOTED: NGRIGGS Date:3/18/2020 a 20' grind and overlay, and street cut fees shall apply. NOTES LEGEND CLOSURE C LOW SPEED 1. DEVICE SPACING FOR THE pOV NSIREAM TAPER SHALL BE ZD'(FT). p TEMPORARY SIGN LOCATION SHOULDER CLOSURE - LOsI[ SPEED y ALL SIGNS ARE BLACK ON ORANGE ( CHANNE.21NG DEVICES CID PROTECTIVE VEHICLE (40 MPH OR LESS) i NOT TO SCALE FIE NAME PS --OTC-SAP TBdE 9•}l PN _ _ _ _ _ _- n.�e FED -AM PRQANO. T Y_/� AStq T CS ---- -- Washington Slats - - - - — Department of Tramportation REGIONAL AD0. - _ TRAFFIC CONTROL. PLAN PA72 BY BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT I > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100, 123' 172' 74' 100, 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED 300' ONE LANE .� ROAD AHEAD 48" 48" W20-4 48. W20-7A ROAD BE WORK PREPARED AHEAD TO STOP 48" 48" W20.1 W20-7111 W20.7B (OPTIONAL IF 40 MPH OR LESS) LEGEND FLAGGING STATION b TEMPORARY SIGN LOCATION D CHANNELIZING DEVICES PROTECTIVE VEHICLE SIGN SPACING = X (1) RURAL HIGHWAYS 60 165 MPH 800't RURAL ROADS 45/55 MPH 500'i RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350't RURAL ROADS, URBAN ARTERIALS, 25 / 30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200't (2) URBAN STREETS 25 MPH OR LESS 100'i (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. 50. TO 100' 6 DEVICE MIN I I R O RK AREA 59TO 100' 6 DEVICE W20-7A ONE LANE ROAD AHEAD� W20-4 W20_7B (OPTIONAL IF 40 MPH OR LESS) 481, 48' BE ROAD PREPARED WORK To STOPrr AHEAD 48" 48" 48. 48' Or . W20.713 ONE LANE W20.1 ROAD AHEAD 48" 48" W20-7A W20-4 BE PREPARED > W20-713 IONAL IF 40 MPH OR(OPTLESS) TO STOP 48' W20-7B 48' ROAD CHANNELIZATION DEVICE SPACING (FEET) MPH TAPER TANGENT 50/65 10 TO 20 80 35/45 10 TO 20 60 25/30 1 10 TO 20 40 WORK NOTES AHEAD 48' 1. ALL SIGNS ARE BLACK ON ORANGE. ONE -LANE, TWO-WAY TRAFFIC CONTROL WITH FLAGGERS NOT TO SCALE 2. EXTENDING THE CHANNELIZING DEVICE TAPER ACROSS SHOULDER IS RECOMMENDED. 3. NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING AT FLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONS FOR ADDITIONAL DETAILS. 4. SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS. Plot 1 TIME 3:05:14 PM s•"•s "WAS FED.AID PROJ.NO. .e " E Amokxnx � �I/ Washington State Department of Transportation .ss TC7� DATE 1/212018 PLOTTED BY Ilddelf DESIGNED BY +". x... Ex sx.E. o. ENTERED BY CHECKED BY c"x.xnm x"wnox xo. TRAFFIC CONTROL PLAN PROJ. ENGR. REGIONAL ADM. REVISION DATE BY 299679 DAVID EARLING 17511 TALBOT RD EDMONDS, WA 98026 Bore/Drill New UG = 105ft Trench New UG = New OH = Overlash = Existing UG = Riser = New Building Interior= New Building Exterior = TOTALFOOTAGE I 105ft SHEET FOR: CONTACTS: Prince Telecom Area Manager Ryan Wilkerson (253)261-1882 Netvision Permit Coordinator Maribel Gonzalez (425)353-2078 COMCAST 'den Lawrence (425) 921-8201 LEGEND Tie in Point Bore Path in Right of Wa New Flush Mount Carson Comcast,. 2x5 sidewalk cut to Expose Water TIE IN BORE PATH FOR APROK 60ft OF CONDUIT IN RIGHT OF WAY. WE WILL MAINTAIN BEHIND THE POLE AND ROCKS IN THE SOFT SURFACE IN ORDER TO MAINTAIN 5 FEET HORIZONTAL CLEARANCE FROM UTILITY APPURTENANCES AND 2 FEET VERTICAL DATE: BY: REASON: REVISION DESCRIPTIONS 3/16/2020 Maribel Gonzalez I DROP BURY We will be making a 2x5 cut in order to expose water on the left side of driveway for house 17512. Then we will bore 60ft south-west, crossing drivweway for house 17512 placing 2inch conduit, starting behind the pole to avoid the catch basin infront of the pole and will maintain behind the rocks in order to maintain a 5ft distance from wet utilties and 2ft from dry. Then we will expose both storm and gas in the soft surface to bore 45ft south-east crossing Talbot Rd and place a new flush mount Carson in the soft surface.