ENG2020-0080
RIGHT OF WAY EUC PERMIT PERMIT NUMBER City of Edmonds ww.cityofedmonds.gov Description: FRONTIER -RELOCATE ONE POLE, REMOVE OLD POLE, REPAIR SIDEWALK ISSUED: 04/08/2020 Address: 22021 76TH AVE W EDMONDS WA 98026-7905 EXPIRES: 10/08/2020 Permit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 27042900305100 NAME TYPE NAME ADDRESS PHONE APPLICANT Frontier Communications Attn: Shelley Haugstad, Everett WA 98201 (425)261-0134 CONTRACTOR PACIFIC CABLE CONSTRUCTION PO BOX 573, WOODINVILLE WA98072 (425)348-7735 OWNER CAMPBELL CHARLES IRWIN 22021 76TH AVE W, EDMONDS WA98020 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 ENGINEERING INSPECTION FEE $330.00 $0.00 RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $0.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. RELEASED BY THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 4/8/2020 DATE Printed: Wednesday, April 08, 2020 7:51:22 AM 1 of 2 -1RRRTF WAY EUC PERMIT City of • • • Ave•:• • 1 1 11:1 ., CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. Contractor/Owner shall be responsible for repair/replacement of all damage to utilities and/or DAMAGE TO FRONTAGE frontage improvements in city right of way per city standards that is caused by or occurs during the IMPROVEMENTS permitted project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQUIRED Maintain erosion & sediment control per city standards. Applicant on behalf of his or her spouse heirs assigns and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from HOLD HARMLESS any and all claims for damages of whatever nature, arising directly or indirectly from the issuance of this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam to 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. UNDERGROUND UTILITY Call for locates of underground utilities prior to any excavation. LOCATES • �� INSPECTION TYPE DATE RESULT NOTES lip COMPLETE X-2 ENGINEERING FINAL** E-7 TRAFFIC CTRL E-7 CONCRETE SIDEWALK Printed: Wednesday, April 08, 2020 7:51:22 AM 2 of 2 of E DA,,O� rNC. I S°1O ROW PERMIT NO.: ENG 2020-0080 ISSUE DATE: 4/8/20 RIGHT-OF-WAY CONSTRUCTION PERMIT APPLICATION PROJECT NAME: 5259817 CONTRACTOR: PACIFIC CABLE CONSTRUCTION Mailing Address: po BOX 573 WOODINVILLE WA 98072 State License #: 36361CON1096 City Business License #: PACIFCC954PJ CONTACT: ADAM DIAZ Phone #: 425-261-013.1 Fax #: N A Email#: ADAM.C.DIAZ(dFTR.COrI ❑ Liability Insurance 0 Bonded ADDRESS OR INTERSECTION OF CONSTRUCTION: INTERSECTION 76TH AVE W & 221 ST PL SW ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: Commercial Subdivision ❑ City Project ❑ Traffic Control (Only) ❑ Multi -Family ❑ Single Family ® EUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit? ❑ Other ❑ Yes _N No ANY ASSOCIATED PERMITS? I BLD# ENG# DESCRIPTION OF PROPOSED WORK (Be Specific) : FRONTIER TO RELOCATE ONE POLE BEHIND THE SIDEWALK. REMOVING THE OLD POLE AND FIXING THE SIDEWALK. REPLACING PANEL. CLOSING ONE LANE USING OPPOSITE LANE FOR TRAFFIC. WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES NO XJ Year: PAVEMENT CUT: ❑ Yes ❑ No If yes, indicate size of cut: x CONCRETE CUT: ❑ Yes ❑ No If yes, indicate size of cut: x RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF NIA SF ley 72 Hrs + LF X LF SF Parking 72 Hrs + LF X LF NIA SF1 APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday NO EXCEPTIONS. Indemnity: The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in er for the permit to be valid. SIGNATURE DATE Z r Z�Dr �ZO ontra or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE TARI F A SIGN SPACING - - X RURAL HIGHWAYS 60/65 MPH 800,± RURAL ROADS 45 55 MPH 500' t URBAN ARTERIALS 35 40 MPH 350' f RESIDENTIAL & BUSINES DIST. 25/30 MPH 200" ± URBAN STREETS 25 MPH OR LESS 100" t MIMNIMUM TAPER LENGTH (L) IN FEET LANE WIDTH (feet) 25 30 Posted Speed 35 40 45 (mph) 50 55 60 65 70 10 105 150 205 270 450 500 550 — I — I — 11 115 1651 225 295 495 550 605 660 — I — 12 125 180 245 320 540 600 660 720 — CHANNELIZING DEVICE SPACING (FT) MPH TAPER TANGENT 50 70 40 80 35/45 30 60 25/30 20 40 C/G & SIDEWALK FORM INSPECTIONS REQUIRED ON ERICONFRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE ENGINEERING DIVISION APPROVED AS NOTED 04/07/2020 NOTE: = ST PL- SW ROAD WORK AHEAD �_A+A A INSPECTION REQUIRED Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. _T1 -1 O O n 0 0 o Io 0 0 0 O 0 0 0 no no no 0: o 0 no 0 0 no 0 he J Q 3 W A N • • =,1311111 1.FLASHING BEACON SHALL BE I p� BE INSTALLED AT EACH SIGN FOR PREPARED NIGHT—TIME USE. osTOP 2.DISTANCES MAY VARY AS APPROVED SWAP SIGNS BY THE ENGINEER. 3. FLAGGERS REQUIRED TO CONTROL U� TRAFFIC WHENEVER THE CONTRACTOR MUST INTERRUPT TRAFFIC FLOW TO ACCESS THE WORK SITE WITH °Naono"E AHEAD MATERIALS OR EQUIPMENT. LEGEND: I ROAD ❑o° CONE OR CHANNELIZING DEVICE i WORK "HEAD (SEE STD 702) TRAM C CONTROL PLAN FTR W. 0 04/2020 51419 2 LANE 2 WAY RD: 1 LANE CLOSED date 5259817 number FRONTIER — 76TH AVE W & 221 ST PL SW N 00 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 1 50 1 55 60 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TMA ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 bs. < 45 MPH 4555 MPH > 55 MPH < 45 MPH 45.55 MPH > 55 MPH 100' 123' 172' 74' 1 100' 150' PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED SIGN SPACING = X FEE FREEWAYS & EXPRESSWAYS 55 170 MPH 1500' +- RURAL HIGHWAYS 60 / 65 MPH 800'± RURAL ROADS 45155 MPH 500'± ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. All spacing may be adjusted to accommodate interchange ramps, at -grade intersections, and driveways. Z iV X X X I U3 B R ROAD WORK SHOULDER AHEAD CLOSED SHOULDER WORK W20-1 I W20-301 W21-5 LEGEND N SIGN LOCATION ®®® CHANNELIZING DEVICES PROTECTIVE VEHICLE - REQUIRED '_3 1 MINIMUM SHOULDER TAPER LENGTH = U3 (feet) SHOULDER Posted Speed (mph) WIDTH (k ) 25 30 35 40 45 50 55 fi0 L. g 40 40 SO 60 40 130 150 ITO 190 m• ao so aD ao �5D no Sao zoo zzo zm USE A MNMUM 3 DEVDES TAPER FOR SHOULDER LESS THEN 8•. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50 / 70 40 80 45150 30 60 NOTES 1. No encroachment on traveled lane. if encroachment is necessary, lane shall be closed. The 2' lateral buffer is recommended. 2. When used, device spacing for the downstream taper should be 20' O.C. 3. If shoulder is used for traveled lanes at certian times, use full L taper and TMA. 4. TMA required for freeways. TYPICAL SHOULDER CLOSURE - HIGH SPEED (45 MPH OR HIGHER) TCP 6 S n a � N 0 Cy S 0 1- CD `/ 0 ('n C CD 3 Cn CDCD CD n C.n 3 3 O CQ� CD a rt O- a O m '► V Its. •, . it I• . irNi ' • . ... .'•' •t- �.. »• .L `. ,`lam; • � �`, -,''. ., 220TH ST SW I �I LLJ >I Q1 C�5 REMOVE I ARM HLLKWAXX 78566 (HLLKWAXX 9) (30-5) (01.1962) HLLKWAXX 9-1 __-_-_- _ I -- FRONTIER 221 ST PL SW -----� c 1(221 ST PL SW) CONSTRUCTION NOTES PLACING AT POLE HLLKWAXX 9-1 -PLACE NEW 35' POLE BEHIND THE NEW S/W PLACED BY THE CITY. POLE WILL BE STAKED. -PLACE ARM ON NEW POLE -TRANSFER FACILITIES FROM OLD POLE(HLLKWAXX 9) -PLACE ANCHOR / DG AT POLE LOCATION HLLKWAXX 9 -REMOVE OLD POLE AFTER FACILITIES ARE TRANSFERRED. -REPLACE S/W PANEL. 0 240' SS 900 26 C95ES DCG,1-6+ XD,7+ C95ES DCG,8-25+ XD, 26-100+ C95ES DCG,101-115+ XD,116-120+ C95ES DCG,121-302+ XD, 303— 308+ C95ES DCG,309-324+ XD, 325+ C95ES DCG,326-330+ XD, 331 + C95ES DCG,332-371+ XD, 372+ C95ES DCG,373-374+ XD, 375+ C95ES DCG,376-380+ XD, 381 + C95ES DCG,382-396+ XD,397+ C95ES DCG,398+ XD,399+ C95ES DCG,400-900 © 500 08.2008 FTTP MULTIPORT 6 HLLKWAXX H 5007, 41— 46 © 1 08.2008 UNK_FIBER HLLKWAXX CABLE H5007,81-84 0 820 08.2008 RBN 216 HLLKWAXX H5007,1-84+ XD,85-168+ XD,169-216 I CERTIFY THAT THE WORK I COMPLETED ON THIS WORK ORDER AND AS -BUILT IS IN COMPLIANCE WITH FRONTIER QUALITY STANDARDS AS IDENTIFIED ON THE IPQIP CHECKLIST. (SIGNATURE AND DATE) TOTAL ALLOTTED HOURS CONTACT SUPERVISOR IF ADDITIONAL HOURS ARE REQUIRED TO COMPLETE PROJECT. CAP. X-TIME MAINT. :REW 1 16 8 12 SPLICING 1 0 0 0 ACCOUNTCODES 0 2411.001 POLES ❑2422.201 UG FIBER 1 2421.101 OH COPPER ❑ 2441.001 CONDUIT 3 2421.201 OH FIBER 034XX.XXX REMOVAL 2422.101 UG COPPER ® 64XX.XXX MAINT. CONSTRUCTION START IN SERVICE DATE 04/24/20 CONSTRUCTION COMPLETE ® ETHERNET ❑ CIAC ❑ DAMAGE ❑ OTHER CONSTRUCTION ❑ DIAL. A DIG []FLAGGING ❑ BRUSHING ❑ CONTRACTING REQ'D PERMITS MUNICIPALITY CITY OF EDMONDS MUNICIPALITY ❑ BLANKET TCP/TRAFFIC ❑ DETAILED (NOT BLANKET) ❑ NO PERMIT REQUIRED JOINT POLE JFN/NJUNS # N/A JFN/NJUNS # N/A 0 NO JPN REQUIRED POLE JPN JPN OWNER TO FROM ❑ ❑ ❑ POWER p ❑ ❑ CATV ❑ ❑ ❑ FRONTIER POINT OF CONTACT TONY SCHNEITER 425-332-4441 SCHEDULING RUSS HESSELMAN PHONE NO.360-658-2260 ENGINEER ADAM DIAZ PHONE NO. 425 261-0134 TECH. PATRICK WINKLER PHONE NO. 425 263-4010 FIELDED BY I anfier" HLLK RDMV EDMONDS S/W ADA INTER 76TH AVE W & 221ST PL SW PROJECT C.O. AREA: 962 NUMBER: EXCH. CODE: DRAWN DATE: ENGR: ADAM DIAZ NTY:SNOHOMISH PHONE: FILE: SCALE: 1=100 TAX DISTRICT: DWG 1 OF fWNSHP: RNG: SEC: