Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ENG2020-0190
RIGHT OF WAY EUC PERMIT City of • • • go Zlk www.cityofedmonds.gov Description: PUD-INSTALL 1 NEW POLE TO REPLACE 2 EXISTING POLES ISSUED: 06/11/2020 Address: 7609 202ND PL SW EDMONDS WA 98026-6844 EXPIRES: 12/11/2020 Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00512700000100 WPermit NAME TYPE NAME ADDRESS PHONE APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA98206 (425)670-3216 CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA98206 (425)670-3216 OWNER LOWELLCYNTHIA 7609202ND PLSW, EDMONDS WA98026-6844 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 ENGINEERING INSPECTION FEE $220.00 $0.00 RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $0.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 06/11 /2020 :»•>/F9:1H ]1 DATE Printed: Thursday, June 11, 2020 12:42:26 PM 1 of 2 -1RRRTF WAY EUC PERMIT PERMIT NUMBER City of Edmonds www.cityofedmonds.gov• • CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. Work approved under this permit may or may not qualify as an essential or allowed activity per the Governors Stay Home, Stay Healthy Order. Refer to the Order and the Citys website for up-to-date information related to development activities during COVID-19. Issuance of this permit does not COVID-19 NOTICE certify that construction is allowed to immediately occur, and inspections may or may not be granted accordingly. Construction activities and all required inspections will resume when the Order has been lifted. Contractor/Owner shall be responsible for repair/replacement of all damage to utilities and/or DAMAGE TO FRONTAGE frontage improvements in city right of way per city standards that is caused by or occurs during the IMPROVEMENTS permitted project. ALERT AFFECTED RESIDENTS AND/OR BUSINESSES PRIOR TO WORK START. ENGINEERING OTHER VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE TO LIKE OR BETTER CONDITIONS. CALL FOR REQUIRED INSPECTIONS AS NOTED. ESC REQUIRED Maintain erosion & sediment control per city standards. Applicant on behalf of his or her spouse heirs assigns and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from HOLD HARMLESS any and all claims for damages of whatever nature, arising directly or indirectly from the issuance of this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam to 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. UNDERGROUND UTILITY Call for locates of underground utilities prior to any excavation. LOCATES F 'ENGINEERING OF INSPECTION TYPE DATE RESULT NOTES COMPLETE X-2 FINAL** E-7 TRAFFIC CTRL Printed: Thursday, June 11, 2020 12:42:26 PM 2 of 2 nF EVA,1(-), ANC. I S,� J RECEIVED 5/20/20 ROW PERMIT NO.: ENG2020-0190 ISSUE DATE: 6/11/20 RIGHT-OF-WAY CONSTRUCTION PERMIT APPLICATION PROJECT NAME: BO Pole 9325 CONTRACTOR: Snohomish County PUD No. 1 Mailing Address: PO Box 1107, Everett WA State License #: City Business License #: CONTACT: Grayson Steele Phone #: 425-783-4156 Fax #: Email #: GRSteele@snopud,com ❑ Liability Insurance ❑ Bonded 7609 202ND PL SW ADDRESS OR INTERSECTION OF CONSTRUCTION: NW corner of 76th Ave W & 202nd PI SW ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: ❑ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only) ❑ Multi -Family ❑ Single Family ® EUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit9 ANY ASSOCIATED PERMITS? ❑ Other ❑ Yes ® No BLD# ENG# DESCRIPTION OF PROPOSED WORK (Be Specific) : PUD to close westbound lane of 202nd PI SW to install (1) new distribution pole to replace (2) existing poles. PUD to transfer all relevant equipment to the new pole, top the existing poles, and abandon them to communications. PUD to perform any tree trimming necessary to ensure proper clearance to energized lines and equipment. WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES ❑ NO ® Year: PAVEMENT CUT: ❑ Yes ® No If yes, indicate size of cut: x CONCRETE CUT: ❑ Yes ® No If yes, indicate size of cut: x RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF SF Alley 72 Hrs + LF X LF SF Parking 72 Hrs + LF X LF SF APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS. Indemnity: The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the permit to be valid. SIGNATURE qtay�. DATE 5/19/2020 Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE LANE CLOSURE BEYOND AN INTERSECTION (WORK AREA ON THE SIDE ROAD) ROAD W20-1 WORK AHEAD X ONE LANE W20-4 ROAD AHEAD X W20-7A x q Z X o C) V` N M M M M X X ROAD WORK AHEAD ONE LANE 3 - 4 W20-1 ROAD W20-7A AHEAD W20-4 13: n � 0 z N p z~ Z_ w Q Z � Q J J J Z STOP 00 0 48" x 24' = ROADNWORK G 2 0 - 2 x (OPTIONAL),3 , 0 W20-4 0 W20-7A ONE LANE �W20-1 ROAD AHEAD ROAD WORK AHEAD X X X 76TH AVE W i r W20-7B BE PREPARED TO STOP OPTIONAL IF 40 MPH OR LESS GENERAL NOTES: 1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD. 2. NOTIFY LOCAL EMERGENCY SERVICES OF CLOSURE TIMES AND DATES (OPTIONAL). 3. SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROAD CONDITIONS. z _ 4. PROTECTIVE VEHICLE RECOMMENDED -MAY BE A WORK TRUCK. Az 5. ALL SIGNS MINIMUM 48" X 48", UNLESS OTHERWISE SPECIFIED. 6. CHANNELIZATION DEVICES ARE 28" REFLECTIVE CONES. SEE TABLE 1 FOR SPACING DISTANCES. 7. ALL SPACING MAY BE ADJUSTED TO ACCOMODATE AT -GRADE INTERSECTIONS AND/OR DRIVEWAYS. FREEWAYS & EXPRESSWAYS 55-70 MPH 1500'± Applicar�t s clar��a�e to per c i �y sta r� clRA1cRCS o cc u rs c1 u r-i r-i g /�1R0 pair/rep - r al 500'± i - FURItAR�EALB✓-$(blf RtSID N�IAL`� MSKMS IST `�S p roJ e B`± (2) IL_ -41 URomll J 1 RLL 1 J I LJ Mrn UR LLJJ I IUU _ %L) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS. fI IP P• I RR VW ONDI'nI I �V- IrrU�A . E TABLE 1 CHANNELIZATION DEVICE SPACING (FEET) MPH TAPER TANGENT 50-65 10 TO 20 80 35-45 10 TO 20 60 25-30 10 TO 20 40 LEGEND: O CHANNELIZING DEVICE r FLAGGING STATION = PORTABLE SIGN AND SUPPORT ®® WORIT VEHICLE WITH FLASHING LIGWORK AREA E MIOM TRAFFIC CONTROL PLAN PUBLIC UTILITY DISTRICT NO 1 PROJECT BO POLE 9325 REPLACEMENT & SYSTEM IMPROVEMENT LOCATION 7609 202ND PL SW, EDMONDS 98026 ENGINEER GRAYSON STEELE DATE 5/19/2020 ORDER 100061685 PHONE 425-783-4156 CELLULAR 425-231-3018 � O PUBLIC UTILITY DISTRICT NO.1 OF SNOHOMISH COUNTY LOCATION 7609 202ND PL SW, EDMONDS 98026 LYNNWOODAREA POLE NO. GC-277 NE1/4S 19 T 27 R 04 DATE 4/13/2020 ORDER 100061685 REASON FOR WORK REPLACE BO POLE 9325. ENGINEER G STEELE OPERATION 0030 RMV POLE 9307 & CAP BANK DRAFTER G STEELE U.G. NO. N/A 4540. SCALE 1"=100' APPROVED & DATE PRINTED DATE WORK COMPLETED FOREMAN FEES REQ'D ❑ YES ■ NO PRIMARY OVERHEAD ❑ RESIDENTIAL ❑ COMMERCIAL LEO NO. SECONDARY OVERHEAD BASIC FEE METER/CONV.POLE s PRIMARY UNDERGROUND ❑ RESIDENTIAL ❑ COMMERCIAL BASIC FEE S LEU NO. '@9 '=s SECONDARY UNDERGROUND BASIC FEE S @3 '=16 UNDERGROUND PLAT BASIC FEE 9 FT.0 _9 STREET LIGHTING (� FT.0 '=9 WORK IN RIGHT OF WAY ❑ PRIMARY ❑ SECONDARY (� FT.@$ '=3 MISCELLANEOUS FEES VAULT S PERMIT S s s s TOTAL DUE 8 DATE PAID RECEIPT NO. SERVICE ORDER NO. F(.FNn: NESC VIOLATIONS ■ NO ❑ YES (SEE NOTES) PERMITS (DATE GRANTED) ❑ TREE TRIM ❑ STATE ❑ COUNTY ■ EDMONDS EASEMENTS ❑ REQUIRED ■ NOT REQUIRED DATE RELEASED FOREIGN CONTACTS ■ JPN# 100061685 ❑ JOINT TRENCH FRONTIER & CATV ❑ JOINT BORE FRONTIER & CATV POLE STENCILING FROM TO TAKE OFF POLE PRE-CONST. REQUIRMENTS ❑ TREE TRIM ❑ PUD LOCATOR ❑ BACKHOE ■ FLAGGING ■ ONE CALL DATE No. STREET LIGHTING ■ YES ❑ NO M&R AS -BUILT CIS GIS QC M&R GIS Ph JOINT USE LOCATION MAP PAGE 455—A5 O EXISTING POLE X EXISTING POLE —TO BE REMOVED • NEW POLE NEW POLE TO REPLACE EXISTING POLE DATE SUBSTATION PRV CIRCUIT NO. 12-126 PHASE 3 GRAYSON STEELE ENGR'S TEL. # 425-783-4156 ENGR'S CELL # 425-231-3018 *NEW POLE TO REPLACE BOTH PLI 9325 & 9307* O POLE PLI # 9325, NEW PLI#-------------- SET 50' CLH2 POLE (PWH2O50, N0110), 10' E OF EXISTING POLE AS STAKED W/ POLE KEY (PF0100) SET DEPTH = 11' USE 5/8" GRVL BCKFLL, CMPCT IN 6" LFTS FRAME (12F337, X0553, X0551, 12V113) 7.2/12.47KV 30 10' SELF—SUPPORTING W/ 10 LATERAL & 7' FG ALLEY ARM FOR NEUT INSTL 100A L.B. CUTOUT & CUTOUT BRACKET (RO102, E0202) FUSE AT 40 AMPS (E1040) RMV 37.5 KVA OH XFMR (12V601, BA21P) UTC #37-7437 SER# 77A290730 HANG 25 KVA OH XFMR (12F601, BA21N) UTC#------------------ SER#------------------- XFR OH SVCS INSTL 12' S/L ARM DIRECTLY E (L0505) INSTL 3" SEC RISER & LARGE PED W OF POLE OU707) RUN 350 KCMIL TPX TO PED L=60' (C1204) INTERCEPT AND REFEED EXISTING SEC SM PED 1N TO NEW PED STRIP, TOP & ABANDON 45' POLE TO COMMUNICATIONS (45', CL2, 1969) ALLEY ARM ASSY © POLE PLI # 9307, STENCIL #GC-277 REFER TO T&D GUIDELINE 4-12-2.0 FOR PROPER DISCHARGE AND HANDLING INFO RMV EXISTING 450 KVAR FIXED CAP BANK #4540 XFER S/L 131567—G TO NEW POLE AT LOC A RMV 8' S/L ARM (L0503) XFER PRI& NEUT TO POLE AT LOC A STRIP, TOP & ABANDON 45' POLE TO COMMUNICATIONS (45', CL2, 1998) S(.HFMATI NTS (BEFORE) (AFTER) PERRINVILLE PERRINVILLE CKT 12-126 CKT 12-126 O GC-277 O GC-277 140 37 CAP#4540 25 140 37 �25 450KVAR t (1) #2 ACSR (1) #2 ACSR PRI & NEUT 321< (1) #2 ACSR (1) #2 ACSR PRI & NEUT 321 (3) 336 AAC PRI & (3) 336 AAC PRI & (1) 3/0 AAC NEUT (1) 3/0 AAC NEUT 7701-M-CDG ND ST�SW SL-1 38-G = 6 � 802 Wr will IQ, 203080 264327 7701 �25- 3 25-9740 SL-131567-G SL-27 A SL-102534-A GC-277 3 1 01 7-7437 CAP 4540 94 17617 9325 9307 202ND PL SW FU40 V v N M P 7612-M L-111959-G 0-M 616-M GC-278 2 25-351355 188024 SHEET 1 OF 1