Loading...
ENG2020-0287RIGHT OF WAY EUC PERMIT PERMIT NUMBER City of Edmonds ..01 1 1 www.cityofedmonds.gov Description: PSE-INSTALL GAS SERVICE ISSUED: 08/12/2020 Address: 655 ALDER ST EDMONDS WA 98020-3415 EXPIRES: 02/12/2021 it Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 00434209502200 W NAME TYPE NAME ADDRESS PHONE APPLICANT PSE/INFRASOURCE 1660 PARK LANE, BURLINGTON WA 98233 (425)457-6353 CONTRACTOR PSE/INFRASOURCE 1660 PARK LANE, BURLINGTON WA 98233 (425)457-6353 OWNER OLSON BRITTA 655 ALDER ST, EDMONDS WA 98020 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 ENGINEERING INSPECTION FEE $110.00 $0.00 RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $0.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 08/12/2020 :»•>/F9:1H ]1 DATE Printed: Wednesday, August 12, 2020 9:32:57 AM 1 of 2 -1RRRTF WAY EUC PERMIT City of • • • •:• •ENG2020-0287 www.cityofedmig;� 771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. Contractor/Owner shall be responsible for repair/replacement of all damage to utilities and/or DAMAGE TO FRONTAGE frontage improvements in city right of way per city standards that is caused by or occurs during the IMPROVEMENTS permitted project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQUIRED Maintain erosion & sediment control per city standards. Applicant on behalf of his or her spouse heirs assigns and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from HOLD HARMLESS any and all claims for damages of whatever nature, arising directly or indirectly from the issuance of this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam to 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. UNDERGROUND UTILITY Call for locates of underground utilities prior to any excavation. LOCATES • �� INSPECTION TYPE DATE RESULT NOTES lip COMPLETE X-2 ENGINEERING FINAL** E-7 RESTOR LIMITS Printed: Wednesday, August 12, 2020 9:32:57 AM 2 of 2 0 \:L L?,11(7. "VC. I S'� J PROJECT NAME: CONTRACTOR: RECEIVED 8/4/20 ROW PERMIT NO.: ENG 2020-0287 ISSUE DATE: 8/12/20 RIGHT-OF-WAY CONSTRUCTION PERMIT APPLICATION 106369065 CONTACT: Susan Sidick PSE/Infrasource Phone #: 425-457-6353 Mailing Address:1660 Park Lane Burlington Wa 98233 Fax #: State License #: INFRASL871C2 City Business License #: Email #: susan.sidick@pse.com ❑ Liability Insurance ❑ Bonded ADDRESS OR INTERSECTION OF CONSTRUCTION: 655 Alder St ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: ❑ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only) ❑ Multi -Family ❑ Single Family ❑ Other ❑ EUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit? ANY ASSOCIATED PERMITS? ❑ Yes ❑ No BLD# ENG# DESCRIPTION OF PROPOSED WORK (Be Specific) : To install gas service at approx 22' S to 13' N cf/1 of Alder St & 90' W c/1 of 7th AVE S (2) 3x5 paving cuts & 1) 3x3 paving cuts anticipated WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES ❑ NO ❑ Year: PAVEMENT CUT: D Yes ❑ No If yes, indicate size of cut: 3 x 5 CONCRETE CUT: ❑ Yes ❑ No If yes, indicate size of cut: x RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF SF Alley 72 Hrs + LF X LF SF Parking 72 Hrs + LF X LF SF APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS. Indemnity: The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the permit to be valid. SIGNATURE 6X-,DQ6IQIN Contractor or Agent DATE NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 %12aaauL /�� LEGEND ® 28" TRAFFIC CONE ® WORK PIT TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS SIGN LOCATION RIGHT OF WAY Row TEMPORARY TRAFFIC CONTROL PLAN TEMPORARY TRAFFIC CONTROL PLAN -;oaro.� J pa;;l w.�ad ay; 6u1-��pl pasr�eo ;e y; sp�epu a;s a6e;u o�; � a1;111;� o; a6e1 Ile aoelcJ a�/�IecJ a� Ileys ;u e� I I I W20-4 ALLEY r��Joo _ Aa J Ic1 c1 I W3-4 I o Z 0 Z/ ■_ ■_ / S O I - 0V3HV ■�■ o ■ ■ i� ■ o o ■�■ ■ z ■ OM PEDESTRIAN DETOUR SIGNAGE TO BE �V ' PLACED AT INTERSECTIONS 6TH AVE S & END ROAD ALDER ST AND ALSO 7TH AVE S & ALDER ST.#655 WORK I receiving pit O I ________ _ _RDY✓_ R_0V _______J - y F- —__ _ ________ _ __ _____-_ �� m ;;' ----- -- 100'� 100' a 100' ------ 0 X 71 W20-1 SIGN SPACING MPH ""XI.60/65 1000, 45/55 500' 35/40 350' 30 200' 25 100, • • • • w------------- •. O RESIDENT(S) WILL BE INFORMED OF POSSIBLE TEMPORARY DRIVEWAY CLOSURE 'c i • • • • w------------- •. O RESIDENT(S) WILL BE INFORMED OF POSSIBLE TEMPORARY DRIVEWAY CLOSURE 'c i m W20-7A a � ✓20- 4 PLACE SIGNS BOTH SIDES OF W34 WORK AREA CHANNELIZATION DEVICE SPACING MPH TAPER TANGENT 55/70 40 80 35/45 30 60 25/30 20 40 END ROAD WORK END ROAD I WORK i i I i I I W 3-4 T— i i I I -0ZM VL-0Z �6-0ZM I /.� i8 to 20 120 Z I I� Ip = io ALLEY 00, - - � � - — - — _ — _ — _ — _ — - — - — PUGET SOUND ENERGY JOB# 106369065 655 ALDER ST, EDMONDS, WA REVISED 8/11/2020 bob.danskin@pse.com 425-398-6168 SHEET 1 of 2 --------------------i F--�--------------- ---- END ROAD ALDER ST WORK Notes: 1. All signs and spacing to conform to the MUTCD • Q W34 and City of Edmonds standards. N 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. DNE ROAD E IT o 3. Channelizing devices are 28" traffic cones. AHEAD Use traffic drums (barrels) with steady burning ROAD WORK o Type C lights on all State Routes and Hwys. AHEAD 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m 8. Work area will be 22' SCL Alder St & 90' WCL 7th Ave S, 1' SCL Alder St & 90' WCL 7th Ave S, 13' NCL Alder St & 90' WCL 7th Ave S. 9. If used, place NO -PARK signs 72 hours in advance of the day that the work is to be done. Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 LEGEND ® 28" TRAFFIC CONE ® WORK PIT TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS SIGN LOCATION RIGHT OF WAY ROW IF 11' TRAVEL LANES CANNOT BE ACHIEVED, UTILIZE SINGLE LANE TRAFFIC CONTROL MEASURES FROM SHEET 1. USE SIDEWALK CLOSURE SIGNS AND PEDESTRIAN DETOURS PER SHEET 1 IF SIDEWALK NEEDS TO BE CLOSED. END ROAD WORK SIGN SPACING MPH "X" 60/65 1000, 45/55 500' 35/40 350' 30 200' 25 100' TEMPORARY TRAFFIC CONTROL PLAN ALLEY i N 0V3HV o MOM &O'd a' o' RESTRICT PARKING #655 I AS NEEDED keep S/W open I ______ ---____--- __J ' ww rV • •LIM • CD. ® • • • • •.• O ----- ---- 100' 100 Zr m O O ono W20-1 W14R CHANNELIZATION DEVICE SPACING MPH TAPER TANGENT 55/70 40 80 35/45 30 60 25/30 20 40 • V-W i i 7T•-•-•-•-r r4-' maintain (2) 11' lanes END ROAD WORK 20 b 20 Q 20 120 � d�4 Q ALLEY PUGET SOUND ENERGY JOB# 106369065 655 ALDER ST, EDMONDS, WA REVISED 8/11/2020 bob.danskin@pse.com 425-398-6168 SHEET 2 of 2 _ - _ - _ - _ - _ - _ - _ - _ - _ - _ - -1 f-------------------- ----------------- ---- END ROAD ALDER ST WORK Notes: ROAD 1. All signs and spacing to conform to the MUTCD AH�ADCN and City of Edmonds standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State Routes and Hwys. i 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. T 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. j 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m 8. Work area will be 22' SCL Alder St & 90' WCL 7th Ave S, 1' SCL Alder St & 90' WCL 7th Ave S, 13' NCL Alder St & 90' WCL 7th Ave S. 9. If used, place NO -PARK signs 72 hours in advance of the day that the work is to be done. Job #: Date: Jurisdiction: ROW Permit: Est. Start Date: Est. Duration: 106369065 7/21 /20 Edmonds Yes 9/18/20 1 Day (8 Hours) Puget Sound Energy Gas Pre -Inspect Form Address: City / Zip: Customer: PM / Inspector 655 Alder St Edmonds, 98020 Elizabeth Voael (858) 531-8365 Noah Fowler (425) 375-3242 Job Description / Scope of Work Install a 52' 1-1/8" PE SCAT stub and a 30' 1-1/8" PE SCAT extension from a 2" MPE IP main on New Construction: o Alder St. Set an A250 meter at inches, located O/F/R of the home. Construction Method All Scat / Trenchless PLAT Map: 163.066 POTHOLE FOR ALL 655 I CITY UTILITIES. CALL FOR RESTORATION LIMITS INSPECTION. I 5/8" MPE A250 AL 20X 1-1 8" PE 30' The service line must maintain a minimum of 5' horizontal and I'vertical seperation from other utilities in the ROW -- — — — — —— 52' -------- ! / Ji — 2 ALD � SEWER 0 GC 2" MPE Ip 2 Tie In 1° L 107008754 2003 IF fV 'S 5/8" IVti F'E Inns Work Location Size of Cut Surface Type 22' South of CL Alder St & 90' West of CL 7th Ave S Tx 5' Asphalt 1' South of CL Alder St & 90' West of CL 7th Ave S Tx 3' Asphalt 13' North of CL Alder St & 90' West of CL 7th Ave S Tx 5' Asphalt Service Information Street Information Job Type Diameter: 1-1/8" PE Flaggers #: Arterial: Residential Conversion SVC EFV: 1-1/8" - 2600 - 9999144 Police #: TCP: Tie -In Fitting Meter: A250 Speed Limit: No Parks #: MDPE - 2" IPS - (DIA) 1"CTS Meter Loc: 01 - OFR Trolley Lines: Mtr Hoods #: Del Press: 6" W.C. Traffic Signal: Bus Stop: ®�� Bollards: 2.5" # 4" # ADA Ramps #: Route #'s: