Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ENG2020-0333
OF WAY EUC PERMIT PERMIT NUMBER City of Edmonds AveRIGHT 9:0ENG2020-0333 www.cityofedmonds.gov Description: PUD-REPLACE UNDERGROUND FEEDERS IN EXISTING CONDUIT ISSUED: 09/02/2020 Address: 200 2ND AVE S EDMONDS WA 98020 EXPIRES: 03/02/2021 Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 27032300409100 NAME TYPE NAME ADDRESS PHONE APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA98206 (425)670-3216 CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA98206 (425)670-3216 OWNER EDMONDS CITY OF 121 5TH AVE N, EDMONDS WA 98020 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 ENGINEERING INSPECTION FEE $110.00 $0.00 RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $0.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 9/2/2020 :»•>/F9:1H ]1 DATE Printed: Wednesday, September 02, 2020 1:16:51 PM 1 of 2 -1RRRTF WAY EUC PERMIT City of • • • •:• •ENG2020-0333 ., CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. Contractor/Owner shall be responsible for repair/replacement of all damage to utilities and/or DAMAGE TO FRONTAGE frontage improvements in city right of way per city standards that is caused by or occurs during the IMPROVEMENTS permitted project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQUIRED Maintain erosion & sediment control per city standards. Applicant on behalf of his or her spouse heirs assigns and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from HOLD HARMLESS any and all claims for damages of whatever nature, arising directly or indirectly from the issuance of this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam to 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. UNDERGROUND UTILITY Call for locates of underground utilities prior to any excavation. LOCATES • L INSPECTION TYPE DATE RESULT NOTES lip COMPLETE E-7 TRAFFIC CTRL X-2 ENGINEERING FINAL" Printed: Wednesday, September 02, 2020 1:16:51 PM 2 of 2 nF EVA,1(-), INC. I S,� J PUD WORKORDER #100067593-60 RECEIVED 9/1/20 ROW PERMIT NO.: ENG2020-0333 ISSUE DATE: 9/2/2020 RIGHT-OF-WAY CONSTRUCTION PERMIT APPLICATION PROJECT NAME: Repl underground feeder cables at Wastewater Plant CONTRACTOR: SNOPUD Mailing Address: 1802 75th St. SW MS 02 Everett, WA 98206 State License #: City Business License #: CONTACT: Richard Dumo Phone #: 425-783-5110 Fax #: Email #: rsdumo @ snopud.com ❑ Liability Insurance ❑ Bonded ADDRESS OR INTERSECTION OF CONSTRUCTION: 200 2nd Ave S, Edmonds WA 98020 ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: ❑ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only) ❑ Multi -Family ❑ Single Family M EUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit9 ANY ASSOCIATED PERMITS? ❑ Other ❑ Yes ❑ No BLD# ENG# DESCRIPTION OF PROPOSED WORK (Be Specific) : PUD crews will pull out and replace undergound feeders in existing 6 inch conduit from Edmonds switching station (near 3rd & Walnut) to the Wastewater plant. There will be no digging needed but crews will have to find and expose manhole covers which are covered by asphalt. Flaggers will be available while crews are working on the side of the road. WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES ❑ NO M Year: PAVEMENT CUT: ❑ Yes No If yes, indicate size of cut: x CONCRETE CUT: ❑ Yes No If yes, indicate size of cut: x RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF SF n/a Alley 72 Hrs + LF X LF SF n/a Parking 72 Hrs + LF X LF SF n/a APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS. Indemnity: The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the permit to be valid. SIGNATURE /& // - DATE 9/1/2020 Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE PARKING LANE CLOSURE (FLAGGER, WORK AREA ON THE SIDE OF THE ROAD) END 0 = ROAD G20-2 Z_ WORK Y U Z a Y a WUj a to + t ROAD W20-1 WORK 'r AHEAD MAINTAIN TWO 11' TRAVEL ■ LANES. OR UTILIZE SINGLE LANE CLOSURE WITH FLAGGERS. O ENGINEERING DIVISION APPROVED AS NOTED O o o NGriggs 09/02/2020 GENERIC Lj Lij TCP � a Applicant shall repair/replace all I damage to utilities or frontage improvements in City right-of-way BUFFER per city standards that is caused or I occurs during the permitted project. TAPER O 50' MIN z O 100' MAX OWNER/CONTRACTOR IS RESPONSIBLE FOR `s ■ a EROSION CONTROL AND DRAINAGE Q C a z I W4-2 Y W Q m ct 0- RIGHT ~ = LANE W20-5R N W W ENDS U END � G20-2 ROAD = N ROA= WORK W20-1 WORK AHEAD SNOHOMISH COUNTY [Flan TRAFFIC CONTROL PLAN PUBLIC UTILITY DISTRICT NO 1 PROJECT REPLACE FEEDER CABLES AT EDMONDS WASTEWATER PLANT LOCATION 200TH 2ND AVE S, EDMONDS WA 98020 ENGINEER RICHARD DUMO DATE 9/1/2020 WO NO 100067593-60 PHONE 425-783-5110 PAGER/ CELLULAR 425-346-8846 SPEED SIGN SPACING BUFFER LIMIT A, B (FT) (FT) 25 200 55 30 200 85 35 350 120 a pro LAYOUT LEGEND: V9 PAD MOUNTED TRANSFORMER ® SUBMERSIBLE TRANSFORMER �J ABOVE GROUND J-BOX �J SUBMERSIBLE J-BOX Q SECONDARY VAULT PULLING VAULT O PAD MOUNTED SWITCH CABINET DAYTON ST SUBMERSIBLE SWITCH CABINET © SMALL SECONDARY PEDESTAL- © LARGE SECONDARY PEDESTAL / SL STREET LIGHT PEDESTAL _U PRIMARY UNDERGROUND CABLE A-17628 EXISTING�L ---------#350 SECONDARY UNDERGROUND CABLE U - - - - - - - - 4/0 SECONDARY UNDERGROUND CABLE A-17629 .•• 1/0 SECONDARY UNDERGROUND CABLE EXISTING ----�—�- STREET LIGHT CABLE SERVICE CONDUIT o POLE AND OVERHEAD LINE PROPERTY LINE (n RIGHT-OF-WAY LINE Li > U EXISTING UNDERGROUND CABLE Q EXISTING DUCT Z — — — — FUTURE DUCT N ------- S------ SANITARY SEWER/MANHOLE ------- D------ STORM DRAIN/CATCH BASIN ------- W ----- ' WATER MAIN/METER - - - - - Y FIRE HYDRANT + STREET LIGHT EXISTING * UNDERGROUND LOCATOR MARKER 65 PVC BEFORE SCHEMATIC A-17621 A-17620 REFER TO SHEET S3B4 EXISTING EXISTIN( Cr UE_KA ATTrl REFER TO SHEET S3 VAULT INSPECTION FORMS: ---------- REFER TO SHEET 67 CONSTRUCTION NOTES: AT EDMONDS SWITCHING STATION: -CUT AND REMOVE EXISTING FEEDER TERMINATIONS. -REMOVE (3) EXISTING 1000 KCMIL FEEDERS FROM A-17618. -INSTALL (3) NEW 1100 KCMIL FEEDERS TO SW 12-2685. -NSTALL (3) NEW FEEDER TERMINATIONS (T1006). -INSTALL CABLE TAGS PER SCHEMATIC. AT VAULT A-17618 (PULL/SPLICE VAULT): -CUT AND REMOVE EXISTING (3) FEEDER SPLICES. -REMOVE EXISTING 1000 KCMIL FEEDERS FROM BOTH DIRECTIONS. -INSTALL NEW 1100 KCMIL FEEDERS FROM SW 12-2685 AND A-17620. -NSTALL (3) HAMMERHEAD SPLICES (Z1362). -INSTALL CABLE TAGS PER SCHEMATIC. AT VAULT A-17620 (PULL/SPLICE VAULT): -CUT AND REMOVE EXISTING (3) FEEDER SPLICES. -REMOVE EXISTING 1000 KCMIL FEEDERS FROM BOTH DIRECTIONS. -INSTALL NEW 1100 KCMIL FEEDERS FROM A-17628 AND A-17518. -NSTALL (3) HAMMERHEAD SPLICES (71362). -INSTALL CABLE TAGS PER SCHEMATIC. AT VAULT A-17628 -EXISTING PMH SWITCH CABINET (12-2677). -CUT AND REMOVE EXISTING FEEDER TERMINATIONS. -REMOVE (3) EXISTING 1000 KCMIL FEEDERS FROM A-17620. -INSTALL (3) NEW 1100 KCMIL FEEDERS TO SW 12-2677. -NSTALL (3) NEW FEEDER TERMINATIONS (T1208). -INSTALL CABLE TAGS PER SCHEMATIC. ALDER ST � I I I I I I I I I I I 605OF 6" PVC I I CABLE ALL FOOTAGES APPROXIMATE BY PUD OR PUD'S CONTRACTOR FROM EDMONDS SWITCHING STATION (SW 12-2685) TO A-17618 390' OF (3) 11000 KCMIL AL JCKTD ERR PRI IN EXST 6" PVC MAKE PO REEL MAKE PO REEL MAKE PO REEL FT MARK TO FROM A-17618 TO A-17620 740' OF (3) 11000 KCMIL AL JCKTD ERR PRI IN EXST 6" PVC MAKE PO REEL MAKE PO REEL MAKE PO REEL FT MARK TO FROM A-17620 TO A-17628 655' OF (3) 11000 KCMIL AL JCKTD ERR PRI IN EXST 6" PVC MAKE PO REEL MAKE PO REEL MAKE PO REEL FT MARK TO TOTAL FOOTAGE OF 1100 KCMIL INSTALLED: 5,355' CABLE NOTES: FROM EDMONDS SW STATION (12-2685) TO A-17628, REMOVE PRIMARY UGND CABLE#'S 52048 THRU 52050. TOTAL FOOTAGE: 5,200' L I EXE XISTING LAYOUT V=60' -- N NORTH Cn EDMONDS W SSTATION X I > STATION J a 2 6p PVC EXISTING 6' PVC — WALNUT ST LOCATION 200 2ND AVE S.EDMONDS 98020 AREA LYNNWOOD POLE NO SEl/4S 23 T 27 R 03 DATE 9/1/2020 ORDER 100067593 REASON FOR WORK REPLACE 30 PRIMARY ENGINEER R. DUMO OPERATION 0060 FEEDER CABLES FOR DRAFTER B. ROSS UGND No 1997-66 EDMONDS WASTEWATER TREATMENT APPROVED SCALE NOTED PLANT & DATE DATE WORK COMPLETED FOREMAN SUBSTATION WESTGATE INSPECTOR CIRCUIT NO 12-404 PHASE 1 2 33 DATE FEES REQ'D ❑YES ■NO ROAD CROSSINGS ONLY PRIMARY OVERHEAD APPV DATE DESCRIPTION ❑ RESIDENTIAL ❑ COMMERCIAL LEO- REVISIONS c$ _$ APPV NO. DATE DESCRIPTION PRIMARY UNDERGROUND ❑ RESIDENTIAL PERMITS (DATE GRANTED) ❑ COMMERCIAL ❑ TREE TRIM LEu# BASIC FEE S ElSTATE ❑ COUNTY •EDMONDs ❑ SECONDARY UNDERGROUND BASIC FEES EASEMENTS ❑ REQUIRED E Eu ■ NOT REQUIRED REQUEST NO. DATE APPROVED FOREIGN CONTACTS ❑ JPN- ❑ JOINT TRENCH FRONTIER & CATV ❑ JOINT BORE FRONTIER & CATV 11 POLE STENCILING WORK IN RIGHT OF WAY ❑PRIMARY ❑sEcaNDFT TQ $ = 8 FROM TO TAKE OFF POLE AS —BUILT APPV N0, DATE DESCRIPTION PRE-CONSTR REQUIREMENTS ❑ TREE TRIM ❑ PUD LOCATOR ❑ BACKHOE ❑ MISCELLANEOUS FEES VAULT 8 ■ ONE CALL DATE PERMIT 8 STREET LIGHTING $ 8 ❑ YES ■ NO S M&R AS -BUILT TOTAL DUE$ GIs DATE PAID CIS QC M&R RECEIPT- CIS Ph JOINT USE ENGINEER RICHARD DUMO CUSTOMER LOCATION MAP PAGE 454, F6 PHONE (425) 783-5110 PHONE WORK SITE PUGET SOUND WOODWAY EDMONDS VICINITY MAP c TAGS z 09 VAULT: EXISTING CABLE: 109225 THRU 109233 b � Wo 6) o