Loading...
ENG2020-0516 ROW PERMITOF WAY EUC PERMIT PERMIT NUMBER City of Edmonds EdmondsRIGHT 98020 1 1 1 www.cityofedmonds.gov Description: COMCAST-OVERLASH, PROOF & PULL FIBER TO CONNECT TO BANK ISSUED: 01/12/2021 Address: 8105 244TH ST SW EDMONDS WA 98026 EXPIRES: 07/12/2021 rmit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 00491100001404 i NAME TYPE NAME ADDRESS PHONE APPLICANT COMCAST 1525 75TH ST SW, EVERETT WA 98203 (425)921-8201 CONTRACTOR Cablecom LLC 20021 120TH AVE NE, SUITE 101, BOTHELL WA 98011 (360)668-1300 OWNER JPMORGAN CHASE BANK NA PO BOX 1919, WICHITA FALLS TX 76307 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 ENGINEERING INSPECTION FEE $110.00 $0.00 RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $0.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW J. Machuyw 01 /12/2021 RELEASED BY DATE Printed: Tuesday, January 12, 2021 10:48:23 AM 1 of 2 -KRWOF WAY EUC PERMIT City of • • • Ave•:• •ENG2020-0516 www.cityofedmonds. ov/425.771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQ Maintain erosion and sedimentation control per City and SWMMW standard requirements. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT COMPLETE E-7 TRAFFIC CTRL X-2 ENGINEERING FINAL" A-1 JOB START Printed: Tuesday, January 12, 2021 10:48:23 AM 2 of 2 0 \:L L?,11(7. "VC. I S'� J RECEIVED DEC 18 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ROW PERMIT NO.: ENG 2020-0516 ISSUE DATE: 1 /12/21 RIGHT-OF-WAY CONSTRUCTION PERMIT APPLICATION PROJECT NAME: JB-526462 CONTRACTOR: Cablecomm, LLC Mailing Address: 1316 BONNEVILLE AVE, BLDG A, SNOHOMISH WA 98290 State License #: CABLE*971DP City Business License #: NR-021818 CONTACT: Jourden Lawrence Phone #: 425-921-8201 Fax #: Email #: j ourden_lawrence@comcast.com ❑x Liability Insurance ❑x Bonded ADDRESS OR INTERSECTION OF CONSTRUCTION: 8105 Lake Ballinger Way, Edmonds, WA 98026 ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: ❑x Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only) ❑ Multi -Family ❑ Single Family x❑ EUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit? ANY ASSOCIATED PERMITS? ❑ Other ❑ Yes ❑ No BLD# ENG# DESCRIPTION OF PROPOSED WORK (Be Specific) : The proposed work in the right of way is to overlash 417' of 48ct fiber to existing Comcast strand proof existing riser/conduit and null 115' of 48ct fiber through existing conduit to vault and continue pull into building. Proposed work in order to provide fiber connectivitv for J.P. Morgan Chase Bank N at address 8105 Lake Ballinger Way. Edmonds. WA 98026. * No disturbance of surface WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES ❑ NO ❑ Year: PAVEMENT CUT: ❑ Yes x❑ No If yes, indicate size of cut: x CONCRETE CUT: ❑ Yes ❑x No If yes, indicate size of cut: X. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF SF Alley 72 Hrs + LF X LF SF Parking 72 Hrs + LF X LF SF APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS. Indemnity: The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the permit to be valid. SIGNATURE �` DATE 12/18/20 Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE � N ROAD Q WORK AHEAD cu t]A KEEP N SIDEWALK CLOSED m E LEFT I I E I CROSS HERE 114-813 o O WITH I I U ro ROLL SPACING TRUCK > 50'MIN 100'MAX WITH WORK FLASHING AREA BEACON N 205th ST Private Drive to be closed for approximately 10 minutes for overlash crossing TABLE A SPEED (MPH) TAPER LENGTH FOR SHIFT WIDTH CONE SPACING ALONG TAPER (FT) 10' 12' 25 105' 125' 25 30 150' 180' 30 35 205' 245' 35 40 270' 320' 40 45 450' 540' 45 N > ROAD Q WORK — AHEAD v W20-1 E E O U N co a WITH SIDEWALK CLOSED CROSS I *Permitted work hours are only M-F 9 AM to 3 PM W4-2R W20-5R W20-1 RIGHT ROAD LANE WORK CLOSED AHEAD AHEAD <W> TAPER LENGTH (SEE TABLE A) % SEE SEE SEE / NOTE 1 NOTE 1 NOTE 1 N 205th ST NOTES 1. DISTANCE BETWEEN SIGNS SHALL BE 100' FOR RESIDENTIAL STREETS (25 MPH) AND 350' FOR ARTERIAL ROADWAYS 0 2. FLASHING BEACON INSTALLED AT EACH SIGN FOR NIGHT-TIME USE (OPTIONAL). 3. DISTANCES MAY VARY AS APPROVED BY THE ENGINEER. 4. SPOTTERS REQUIRED WHENEVER THE CONTRACTOR MUST INTERRUPT TRAFFIC FLOW TO ACCESS THE WORK SITE WITH MATERIALS OR EQUIPMENT (FLAGGING REQUIRES 3 OR 4 SIGN SETUP). 5. SIGN SIZE PER MUTCD. 6. THIS PLAN IS PROVIDED AS A GUIDE ONLY. FOR SPECIFIC INFORMATION ON TRAFFIC CONTROL PLANS SEE CURRENT MUTCD. LEGEND 0 CONE OR CHANNELIZING DEVICE SEE STANDARD DRAWING 713. Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE ENGINEERING DIVISION APPROVED AS NOTED �-2t �'9-6Y' 01/12/2021 TITLE TRAFFIC CONTROL PLAN 5 LANE ROADWAY WITH RIGHT LANE CLOSURE FAR SIDE OF INTERSECTION C) C N v1 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TMA ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 123' 172' 74' 100' 150' MINIMUM TAPER LENGTH = L (feet) LANE WIDTH (feet) Posted Speed (mph) 25 30 35 40 45 50 55 60 65 70 10 105 150 205 270 450 500 550 - - - 11 115 165 225 295 495 550 605 660 - - 12 125 180 245 320 540 600 660 720 780 840 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER Posted Speed (mph) WIDTH WIDTH 25 30 35 40 45 50 55 60 65 70 8' 40 40 80 90 120 130 150 160 170 190 10' 40 60 90 90 150 170 190 200 220 240 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 5'. SIGN SPACING = X (FEET) ( 1 ) FREEWAYS & EXPRESSWAYS 55170 MPH 1500'+- RURAL HIGHWAYS 60/65 MPH 800'± RURAL ROADS 45/55 MPH 500'± RURAL ROADS & URBAN ARTERIALS 35/40 MPH 3501± RURAL ROADS, URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 25/30 MPH 200'± (2) URBAN STREETS 25 MPH OR LESS 100'± (2) ALL SIGNS ARE 48" X 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. PROTECTIVE VEHICLE (WORK VEHICLE) = R 11 (1) All spacing may be adjusted to accommodate interchange ramps, NO SPECIFIED DISTANCE REQUIRED at -grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway �I conditions. Spotter to assist pedestrians through work zone b b N 205th ST ® ®® ® ¢ WORKAREA SEE d X X X LI3 L BOTE4 R 100'± V W20-1 W4-2(L) N RIGHT LANE CLOSED AHEAD LEGEND W20-5R CI SIGN LOCATION CDD ARROW BOARD ® ® ® TRAFFIC SAFTEY DRUMS/TALL CHANNELIZATION DEVICES a ® ® CHANNELIZING DEVICES TMA PCMS PORTABLE CHANGEABLE MESSAGE SIGN (RECOMMENDED) (SAMPLE MESSAGE) PCMS 1 2 RIGHT 1 LANE MILE CLOSED AHEAD 2.0 SEC 2.0 SEC FIELD LOCATE 1 MILE ± IN ADVANCE OF LANE CLOSURE TAPER. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50 / 70 40 80 35 / 45 30 60 25/30 20 40 NOTES 1. A TMA is required for roadway 45 mph or higher. For roads 40 mph or less - If a TMA is not available, the protective vehicle shall be strategically located in the field to shield workers and no roll ahead distance is specified. 2. Extend device taper across shoulder. 3. Devices should not encroach into adjacent lanes, see sheet TCP 16 for encroachment detail. The 2' lateral buffer is recommended. 4. Use transverse devices in closed lane every 1000' - when work operation allows. 5. Traffic safety drums or tall channelization devices required for all lane closure tapers on roadway 45 mph or higher. (Half spacing required for tall channelization devices). 6. When used, device spacing for the downstream taper should be 20' O.C. 7. Coordinate with Region Traffic office for work hour restrictions. TYPICAL SINGLE -LANE CLOSURE FOR MULTI -LANE ROADWAYS TCP 3 Route Overview Completed By: KCS Address: 8105 LAKE BALLINGER WAY, EDMONDS, WA 98026 Completion Date: 12/8/2020 Footages COMCAST Survey Revision Date: New Aerial Coax 0 Overlash Coax 0 New UG Fiber 115 Survey Revision Task ID: New Aerial Fiber 0 Overlash Fiber 417 Existing UG Fiber 0 Engineered For: ISP Footage 0 New UG Coax 0 Total Aerial 417 Project Manager: Conduit Only 0 Existing UG Coax 0 Total Underground 115 P2 ID: JB0000526462 Are Additional Pages Needed No Total Private Footage 0 Right of Way Completed By: KCS N �� p E , • ; ' •� s Completion Date: 12/8/2020 Address 8105 LAKE BALLINGER WAY, EDMONDS, WA98026 COMCAST Survey Revision Date: Survey Revision Task ID: Footages Entered On Route Overview Sheet Engineered For: Project Manager: - P2 ID: JB0000526462 Additional Pages Needed No Legend New Ped ❑ Pole & SET NEW STRAP OUT OF OVERLASH 1-48CT SP.WALY.0223 AND TIE IN , New Vault Lock Box E Existing U/G Footage 150' Existing Aerial Text Box Text C New U/G Callout Arrow 70 New Aerial --- New Tap 0 Fqw —� Interior Path Phase Identifier ❑1 — Footage Break Power Supply PS Fiber Splice Point H Hard Surface Cut Right of Way \� Provide Project Clear Detail about the Pro 1 OVERLASH 1-48CT FIBER OVERLASH 1-48CT PROOF AND PULL 48CT FIBER THROUGH Construction Notes: OCCUPIED CONDUIT THAT LEADS TO VAULT IN SOFT SURFACE, THEN } TRANSITIONS TO 4" THAT LEADS TO 169 V ..ram-- - � ,-,.• ' Private Exterior Completed By: KCS rAr Completion Date: 12/8/2020 Address 8105 LAKE BALLINGER WAY, EDMONDS, WA 98026 , •'O • .� � gill �� Survey Revision Date: Survey Revision Task ID: Footages Entered On Route Overview Sheet _ Engineered For: COMCAST Project Manager: - S P2 ID: JB0000526462 Additional Pages Needed No From: CCI Systems - <cci@cartobiz.co> Sent: Thursday, January 7, 2021 10:11 AM To: Edmonds Engineering Permits Cc: Lawrence, Jourden; Jennifer L. Ewing Subject: Re: FW: ROW Permit Application ENG2020-0516 - 8105 Lake Ballinger Way Categories: Green category Good Morning, Please see marked responses below. Let us know if anything else is needed. Thank you! 1. Please confirm that the undergrounding is all in existing conduit and that no digging will occur. -No digging is proposed; underground work is through existing conduit and existing vault. 2. With regard to the traffic control plan, how long do crews anticipate for crossing the intersection at the private drive? Approximately 10 minutes. The only overlashing is on the north side of the intersection, correct? YES So traffic would only need to be temporarily stopped going into and out of that drive then? YES Please confirm. If you need to shut down the intersection, a City of Edmonds officer will be required. I will include the contact information and steps upon issuance of the permit. INTERSECTION WILL NOT BE REQUIRED TO BE SHUT DOWN; ONLY TRAFFIC IN AND OUT OF PRIVATE DRIVE FOR APPROX 10 MIN Given the job location, please note work hours will be limited to 9 AM to 3 PM Monday through Friday. NOTED On Wed, Jan 6, 2021 at 3:35 PM Lawrence, Jourden <Jourden Lawrence@comcast.com> wrote: FYI From: Edmonds Engineering Permits<EngineeringPermits@edmondswa.gov> Sent: Wednesday, January 6, 2021 1:31 PM To: Lawrence, Jourden <Jourden Lawrence@comcast.com> Subject: [EXTERNAL] ROW Permit Application ENG2020-0516 - 8105 Lake Ballinger Way Hi Jourden, I have reviewed the application and I have a few questions/comments: