Loading...
ENG2020-0478 ROW PERMITRIGHT OF WAY EUC PERMIT PERMIT NUMBER City of Edmonds -0478 www.cityofedmonds.gov Description: COMCAST-BORE FOR 2" CONDUIT AND PLACE CARSON ISSUED: 01/21/2021 Address: 525 HOLLY DR EDMONDS WA 98020-3418 EXPIRES: 07/21/2021 Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 27032500207500 NAME TYPE NAME ADDRESS PHONE APPLICANT COMCAST 1525 75TH ST SW, EVERETT WA 98203 (425)921-8201 CONTRACTOR PRINCE TELECOM 13701 24TH ST E, BLDG G, SUMNER WA 98390 OWNER MORCK MICHAEL UNKNOWN, UNKNOWN WA FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 ENGINEERING INSPECTION FEE $110.00 $0.00 RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $0.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW J. Ma,d 4w 01 /21 /2021 RELEASED BY DATE Printed: Thursday, January 21, 2021 10:05:52 AM 1 of 2 -KRWOF WAY EUC PERMIT PERMIT NUMBER City of • • • •:• •ENG2020-0478 31 www.cityofedmonds. ov/425.771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQ Maintain erosion and sedimentation control per City and SWMMW standard requirements. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT COMPLETE X-2 ENGINEERING FINAL" E-7 RESTOR LIMITS Printed: Thursday, January 21, 2021 10:05:52 AM 2 of 2 0 \:L L?,11(7. "'VC. I S'� J RECEIVED 11/30/20 ROW PERMIT NO.: ENG 2020-0478 ISSUE DATE: 1 /21 /21 RIGHT-OF-WAY CONSTRUCTION PERMIT APPLICATION PROJECT NAME: COMCAST # 290849 CONTRACTOR: PRINCE TELECOM Mailing Address: 13701 24TH ST E BLDG G SUMNER, WA 98390 State License #: PRINCTL862PS City Business License #: CONTACT: COMCAST C/O JOURDEN LAWRENCE Phone #: 425-967-1158 Fax #: Email #: jourden_lawrence@comcast.com X❑ Liability Insurance X❑ Bonded ADDRESS OR INTERSECTION OF CONSTRUCTION: 525 HOLLY DRIVE ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: ❑ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only) ❑ Multi -Family ❑ Single Family ❑ Other X❑ EUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit? ANY ASSOCIATED PERMITS? ❑ Yes X❑ No BLD# ENG# DESCRIPTION OF PROPOSED WORK (Be Specific) : Contractor to start bore in the northeast side of 510 Holly Dr and bore north for 25' of 2" conduit and place Carson on 525 Holly Dr Property line. 1-2x5 cut to expose water line. WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES ❑ NO ❑ Year: PAVEMENT CUT: © Yes ❑ No If yes, indicate size of cut: CONCRETE CUT: ❑ Yes X❑ No If yes, indicate size of cut: 2 x 5 x RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF SF Alley 72 Hrs + LF X LF SF Parking 72 Hrs + LF X LF SF APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS. Indemnity: The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the permit to be valid. SIGNATURE DATE 11 /30/2020 Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE www.invarion.com SIGN SPACING -- X (FEET) (1) FREEWAYS & EXPRESSWAYS 55170 mph 150M RURAL HIGHWAYS 60165 mph 800+I• RURALROADS 45155mph 500a+I. RURAL ROADS and URBAN ARTERIALS 35/40mph 350N+I- RURAL ROAD, URBAN ARTERIALS RESIDENTIAL& BUSINESS DISTRICTS 25130mph 20OR+1•(2) URBAN STREETS 25mph or less 100fl+1• (2) ALL SIGNS ARE 48" x 48' BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED (1)All spadng maybe adjusted to accomodate interchange ramps, ad -grade intersedions, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. MERGING, SHIFTING, and SHOULDER TAPER LENGTHS and NUMBER OF CHANNELIZATION DEVICES USED .idth 11LANE 110LANE 1201ANE L 112E L 112L L 112L 113E MPH kiw a%og kNRIN Ng Brv[rs SS o9 kv M4 I- RIB! MPH kE 20 10 6 35 3 1S 6 40 3 80 6 40 3 20 25 3 25 10S 6 SS 4 115 i 60 4 125 7 65 4 25 35 3 30 150 1 75 5 16 9 M 5 1n 10 90 5 30 S 3 35 205 8 HIS 5 N5 9 115 5 245 9 125 5 35 70 4 40 270 10 135 6 NS 11 150 6 320 12 in 6 40 90 4 45 450 16 225 9 46 18 3 9 i40 19 270 10 45 150 6 50 500 14 250 8 50 16 2 5 8 600 i6 300 9 50 170 6 55 550 15 275 8 WS 16 303 9 660 18 330 9 55 18S 6 60 600 16 300 9 10 18 313 9 720 19 360 f0 60 200 6 65 650 17 325 9 715 19 370 10 iM 21 390 11 65 220 7 70 700 19 350 10 7r0 20 315 11 840 22 420 12 70 235 7 D RMWN Kouarvmmms�a3 PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE LONGITUDINAL BUFFER SPACE = B TYPICALPROTECIIVE IYPIGLLfMNCIMVBIICLE STATIONARY VEHICLE ME MIOITN UUDEDMIGM OPEPAnON WITH TMA ILBBI m) 4 YARD DUMP TRUCK EMMIX%PNNIN 30 MIN. SPRWCETRUCK MIDMYNPSMMEXIfD]gMMF FLAT BED, ETC MMMN aEA1NMN 100 max. ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT APAOTECIIVEVEXICIEISMCOMMENDEO REGARDLE991FA1MAISAVNIABLEIPNOMAISOBED, 7HEPAO1EUTAVEHICLESOLLBESIAAIEGICALLYLOIUEDINIXE EIELDTOSMELDWORKEASAND NDRDLLUEODOWDEIsSRECIEIED BEPERTOCHAnTEBLssTc"ADDNIOxnLWPGAM MINIMUM TAPER LENGTH = L (feet) LANE POSTED SPEED (mph) f.) 25 30 35 40 45 N 55 60 65 70 10 105 1150 1205 1 A 14M 1 NO 550 - - 11 115 165 225 a 495 90 605 6W 12 125 180 245 NO 540 600 660 720 78 8840 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEEDImIIIIII 25 1311 35 14 19 1 50 I SS IN 19 70 LENGTHIH)l 151111111211315111411576 1 645 1730 MAINTAIN MINIMUM 11' TRAVEL LANE END ROAD WORK Holly Dr I B ►-M —► v u W204 20-7a ROAD E WORK ID AHEAD N W3-4 525 fI.S%emount Carson 510 CHANNELIZING DEVICE SPACING CHART (FEE1 mph 'HalfSpacing' TAPER TANGENT 50170 20 40 80 35145 NIA 30 60 201H NIA 20 40 Road n bore 2W Open cut to O Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. expose sewer NORTH Prince telecom telecommunications installation Angelique Loiselle 206-641-9903 NOT TO SCALE JOB # 290849 ENGINEERING DIVISION APPROVED AS NOTED 01 /20/2021 W3-4 UL-OZM V_OZM 6-OZM z c pY� • DID K O = 0 3a HI —> IOU Tool, Loo L W IR END ROAD WORK cones - KENNYS TRAFFIC ZONE PLANS P.F. 4BKN®. flogger - aPE OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE 290849 JANE MORCK 525 HOLLY DR EDMOND5 SECTIONS: COVER PAGE 1 SOW OVERVIEW DETAIL 2 SOW DETAIL VIEW 3 SOW DETAIL VIEW 4 CONTACTS: Area Manager Ron Grosvenor(253)254-9658 ESS COMCAST Jourden Lawrence (425)967-1158 LEGEND ® Tie in Point Bore Path New Flush Mount Carson x Cut To Expose Utilities Bore/Drill New UG = 25 New UG = Building Attachment New OH = Overlash = Drop Path Existing UG = New Lock Box Riser = New Building Interior= New Building Exterior= New Pedestal POE TOTALFOOTAGE 25 yPE / 'I NEW FLUSH UkAm MOUNT CARSON 1.� It7 94 P51 - 11-106 BORE PATH FOR 25' CONDUIT. ALL SUBSTRUCTRE TO DATE: BY. REASON: REVISION DESCRIPTIONS 11/30/2020 1 ANGELIQUE LOISELLE I DROP BURY Contractor to start bore in the northeast side of 510 Holly Dr and bore north for 25' of 2" conduit and place Carson on 525 Holly Dr Property line. 1-2x5 cut to expose water line.