Loading...
0125_001Project: M2880A3FT-5 Location: 04. DINING ROOM DOOR HEADER 3/11/2020 Multi -Loaded Multi -Span Beam [2015 International Building Code(2015 NDS)] 3.5INx15.0INx10.0FT 24F-V4 - Visually Graded Western Species - Dry Use Section Adequate By: 35.3% Controlling Factor: Shear DEFLECTIONS Center Live Load 0.11 IN U1118 Dead Load 0.06 in Total Load 0.17 IN U719 Live Load Deflection Criteria: U480 Total Load Deflection Criteria: U360 REACTIONS A _Q Live Load 3190 lb 4382 lb Dead Load 1688 lb 2471 lb Total Load 4878 lb 6853 lb Bearing Length 2.14 in 3.01 in BEAM DATA Center Span Length 10 ft Unbraced Length -Top 0 ft Unbraced Length -Bottom 10 ft Live Load Duration Factor 1.00 Camber Adj. Factor 1 Camber Required 0.06 Notch Depth 0.00 MATERIAL PROPERTIES 24F-V4 - Visually Graded Western Species Base Values Adjusted Bending Stress: Fb = 2400 psi Controlled by: Fb_cmpr = 1850 psi Fb' = 2400 psi Cd=1.00 Shear Stress: Fv = 265 psi Fv' = 265 psi Cd=1.00 Modulus of Elasticity: E = 1800 ksi E' = 1800 ksi Comp. -L to Grain: Fc -1= 650 psi Fc - -L = 650 psi Controlling Moment: 17654 ft-lb 5.5 Ft from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Controlling Shear: -6853 lb At right support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Comparisons with required sections: Read Provided Section Modulus: 88.27 in3 131.25 in3 Area (Shear): 38.79 in2 52.5 in2 Moment of Inertia (deflection): 492.56 in4 984.38 in4 Moment: 17654 ft-lb 26250 ft-lb Shear: -6853 lb 9275lb page Jeffrey deRou let / StruCalc Version 10.0.1.4 3/17/2020 2.46:41 PM or A to « UNIFORM LOADS Center Uniform Live Load 410 pif Uniform Dead Load 105 pif Beam Self Weight 11 plf Total Uniform Load 526 plf POINT LOADS - CENTER SPAN 1 Load Number One Two Live Load 1780 8 lb 1691 lb Dead Load 1068 lb 1127 lb Location 5.5 ft 8 ft TRAPEZOIDAL LOADS Load Number - CENTER SPAN One Left Live Load 0 pif Left Dead Load 80 plf Right Live Load 0 plf Right Dead Load 80 plf Load Start 0 ft Load End 10 ft Load Length 10 ft J1047991F2 IF12 'BL`) 2019 - 0(. S-7, 2 i 1 0-1-8 H I- �=6•�---I 1.9 4 0-0-10 I— - — -I 6'-0" 2x6 DF No.2 scab to one face 0 1-8 Scale = 1:33.0 2 1/2" NOTCH�T/C 1.5x4 II 2x4 II 3x4 = 1.5x4 11 4x4 = 3x4 II 3x6 FP = 3x6 — 1.5x4 11 3x4 = 2x4 11 1 2 3 4 .9 6 7 89 10 11 22 6 211 3x4 3x6 3x6 FP= 3x8 == 3x4 = 3x4 REPAIR: Notch in top chord 7-8 and web 7-14 as shown. 3x4 1) Attach a 2x6 DF No.2 scab (6'-0" long) to one face of the top chord using Simpson SIDS 1/4"x5" woodscrews; 1-row staggered and spaced at 4" o.c. in all members 2) Attach a 2x6 DF No.2 scab (full length) to one face of web extending into top chord using Simpson SIDS 1/4"x5" woodscrews; 1-row staggered and spaced at 4"o.c. in all members. 9-9-4 - - 10.8.2 - Plate_ -- LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.43 Vert(LL) -0.03 12-13 >999 480 MT20 185/148 TCDL 10.0 Lumber DOL 1.00 BC 0.30 Vert(CT) -0.09 12-13 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.31 Horz(CT) 0.01 12 n/a n/a BCDL 5.0 Code IRC2015ITP12014 Matrix-SH Weiaht: 91 lb FT = 20%F. 9%E LUMBER- BRACING - TOP CHORD 2x4 HF No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 HF No.2(flat) end verticals. WEBS 2x4 DF Stud(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 0.5-8. (lb) - Max Grav All reactions 250 lb or less at joint(s) except 18=453(LC 3), 18=402(LC 1), 12=498(LC 4), 15=1346(LC 1), 15=1346(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-690/42, 3-4=-690/42, 4-5=0/830, 5-6=0/832, 6-7=0/832, 7-8=-847/0, 8-9=-847/0, 9-10=-847/0 BOT CHORD 17-18=0/614, 16-17=-318/199, 15-16=-318/199, 14-15--172/408, 13-14=0/847, 12-13=0/701 WEBS 2-18=-697/0, 3-17=-255/0, 4-17=0/672, 4-15=-910/0, 7-15=-1158/0, 7-14=0/583, 10-12=-796/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Attach ribbon block to truss with 3-10d nails applied to flat face. 3) Non Standard bearing condition. Review required. 4) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1 v55 SnI X ti.i- nu,.. Q^( g+ 4fz _. EXPIRES 04-11-20 FEBRUARY 19, 2020