0721_001(Medical Gas Services 918 S Horton St, Suite 917 Seattle, WA 98134 medgasservices.io (425) 894 5918 URN= S301AH38 1N311JdOBA30 au i? z 933 C13AI3338 Medical Gas Line Verification Report Date: February 121h, 2021 Job Number: 2896 Contractor: University Mechanical Contractors, Inc. Date(s) / Time(s) of Testing: February 121h, 2021-1300 hrs. Facility: Swedish Edmonds Campus 21601761h Ave W Edmonds, WA 98026 Scope of Work: Installation of new medical gas inlets/outlets to existing distribution system Our firm certifies that the verifier named in the report is properly trained and certified to perform the activities required. All testing and measurement equipment are properly calibrated and maintained. As a representative of Medical Gas Services, LLC, the verifier named in this report has conducted testing and verification of medical gas piping systems and related equipment to certify the following on the above date. General Findings: A. Medical gases and vacuum are in compliance with NFPA 99 (2012ed): Category 1 B. No crossed lines were found in medical gas or vacuum systems in the tested areas on the day of testing. C. Medical gases meet minimum concentration. D. Medical gases meet minimum flow and are at normal pressure. E. Medical vacuum meets minimum flow and is at normal vacuum pressure. F. Medical gas system components in the area tested are in compliance with NFPA 99 (2012ed). G. Permit #: BLD2021-0029 / City of Edmonds H. Attachments: Worksheets Note: Existing Equipment and Systems NFPA 99(2012ed) &51.14 - An existing system that is not in strict compliance with the provisions of this standard shall be permitted to be continued in use as long as the authority havingiurisdiction has determined that such use does not constitute a distinct hazard to life. 2896-2.12.21-VR Pg 1 of 3 Medical Gas Services 918 S Horton St, Suite 917 Seattle, WA 98134 medgasservices.io (425) 894 5918 II. Medical Gases: A. Oxygen: 1. Static Line Pressure: 54.9 psi 2. Dynamic Outlet Free Flow: >3.5 scfm 3. Dynamic Outlet Free Flow: >6.0 scfm (for 3 seconds in 'Critical Care Area') 4. Oxygen Concentration: 97.4 5. Delta Flow: PASS B. Medical Air: 1. Static Line Pressure: 51.2 psi 2. Dynamic Outlet Free Flow: >3.5 scfm 3. Dynamic Outlet Free Flow: >6.0 scfm (for 3 seconds in 'Critical Care Area') 4. Oxygen Concentration: 20.3 % 5. Delta Flow: PASS 6. Carbon Monoxide: Non -Detectable 7. Carbon Dioxide: 382 ppm B. Dew Point: -17' F III. Vacuum: A. Medical - Surgical Vacuum 1. Static Line Vacuum: 21.82" HgV 2. Dynamic Inlet Free Flow: >3.0 scfm 3. Delta Flow: PASS IV. Particulate Test: PASS V. Odor: None VI. Outlets / Inlets: A. Brand: Multiple B. Quick Connect Style: Chemetron VII. Zone Valves: A. Brand: Chemetron B. Down line gauges: Yes C. Labeled for Area Controlled: Yes VIII. Alarms: A. Area Alarms: 1. Brand: Chemetron 2. Labeled for Area Monitored: Yes 2896-2.12.21-VR Pg 2 of 3 Medical Gas Services 918 S Horton St, Suite 917 Seattle. WA 98134 medgasservices.io (425) 894 5918 IX. Brazier: Gregory Lincoln A. Brazier Number: LINCOGJ918CP B. Contractor: University Mechanical Contractors, Inc. X. Comments: A. None XI. Recommendations: A. None Tested By: Alexander Christensen - Medical Gas Technician Reviewed By: Matthew Wachsmuth - ASSE 6030 Verifier 2896-2.12.21-VR PS 3 of 3 Medical Gas Services 918 S Horton St, Suite 917 Seattle. WA 98134 medgasservices.io (425) 894 5918 Medical Gas Outlet / Inlets Evaluation Worksheet Facility: Swedish Edmonds Campus Job #: 2896 Date: 2.12.21 Area Tested: Family Childbirth Center Verifier: AC lone VeVve - r-I None M Not Required M New 5a Existing Labeled As: Patient Rooms 704 thru 707 1 ZV Brand: Chemetron Gas 3 Part Valve DL Gauge Go. PSI Act PSI Comments: OX 0 Yes ❑ No ® Yes ❑ No 54 54.9 MA 0 Yes ❑ No 0 Yes ❑ No 50 51.2 VAC 0 Yes ❑ No 0 Yes ❑ No 23 21.82 Area AVarm - I—i None Fl Not Required r-I New IRI Existing Labeled As: Patient Rooms 704 thru 707 Brand: Chemetron Gas PSI Set HI Set LO Sensor Comments: OX 55.4 60 40 DL MA 50.7 60 40 DL VAC 22.0 -- 12 DL vuriers tr inners - M New m txistinQ Outlet / Inlets Brand: Chemetron/BM Location: Wall I Quick Connect: Chemetron Area Room Door Gas Flow SCFM Delta Flow Conc. Part.Comments: 706 OX >8 .8 97.4 .000 Mother - New VAC 4.5 >12 -- -- OX >8 .8 97.4 .000 Baby - Existing VAC 4.5 >12 -- -- 707 OX >8 .8 97.4 .000 Mother - New VAC 4.5 >12 -- -- OX >8 .8 97.4 .000 Baby - New VAC 4.5 >12 -- -- MA >8 1.0 20.3 .000 DP:-17°F CO2:382ppm CO:Oppm 2896-2.12.21 Page 1 of 1 CMtdical Gas Services 8 S Horton St, Suite 917 Seattle. WA 98134 medgasservices.io (425) 894 5918 Medical Gas Outlet / Inlets Evaluation Worksheet Facility: Swedish Edmonds Campus Job #: 2896 1 Date: 2.12.21 Area Tested: Family Childbirth Center Verifier: AC Zone Valve - --1 None Fl Not Reauired F-1 New 15ZI Existina Labeled As: Patient Rooms 708-713 1 ZV Brand: Chemetron Gas 3 Part Valve DL Gauge Ga. PSI Act PSI Comments: OX ® Yes ❑ No ® Yes ❑ No 55 54.9 MA ® Yes ❑ No ® Yes ❑ No 51 51.2 VAC ® Yes ❑ No ® Yes ❑ No 26 21.82 AreaA/arm- F-1 None Fl Not Reauired FI New IRI Fxistino Labeled As: Patient Rooms 708-713 6 715 (Air) Brand: Chemetron Gas PSI Set HI Set LO Sensor Comments: OX 54 60 40 DL MA 52 60 40 DL VAC 22.1 -- 12 DL UUtletS & Inlets - ixl New I I Existing Outlet / Inlets Brand: BeaconMedaes Location: Wall I Quick Connect: Chemetron Area oom oor Gas Flow SCFM Delta Flow Conc. Part.Comments: 708 MA >8 1.0 20.3 .000 VAC 4.5 >12 -- -- OX >8 .8 97.4 .000 VAC 4.5 >12 -- -- OX >8 .8 97.4 .000 713 OX >8 .8 97.4 .000 VAC 4.5 >12 -- -- MA >8 1.0 20.3 .000 OX >8 .8 97.4 .000 VAC 4.5 >12 -- -- 2896-2.12.21 Page 1 of 1