Loading...
FIR2021-0025_Fire_Alarm_Equipment_Specification_Sheets_3.16.2021_9.39.04_AM_2094453Honeywell ®SILENT' I0aGHT SK-MONITOR Intelligent Monitor Module The SK-MONITOPis an addressable monitor module for use with Honeywell Silent Knight Series fire alarm control panels (FACPs). The SK-MONITOR is intended for use in intelligent, two -wire systems, where individual address of each module is selected using the built-in rotary switches. The SK-MONITOR supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. 112F4ill 14+eN11[•]21 The SK-MONITOR mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor' PN SMB500) is available from Silent Knight. FEATURES & BENEFITS • Single contact monitor • Panel controlled • Support for Class A status LED that and Class B wiring flashes green in normal state and is • Fully supervised solid red in alarm • SEMS screws for easy wiring • UL Listed • Rotary address switches for fast installation SK-MONITOR SK-MONITOR Technical Specifications For a complete listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.sitentknight.com. Height: 4.5"H x 4" W x 1.25"D (11.4 X 10.2 X 3cm) SK-MONITOR: Monitor Module Shipping Weight: 6.3 oz (196 g) Microsoft, Windows, and the Windows Logo are ACCESSORIES. registered trademarks ELECTRICAL SM6500:4" Square surface mount electrical box or trademarks of Operating Voltage: 15 — 32VDC Microsoft Corporation. Current Draw (LED on): 5.OmA max COMPATIBILITY Silent Knight ,System Operating Current (LED flashing): 375µ The SK-MONITOR icompatible with the e s comA p Sensor' and Honeywell' Standby Current: 400µA max @ 24 VDC (one following Honeywell Silent Knight fire alarm are registered communication every 5 sec with 47K EOL); 550 µA control panels: trademarks of Honeywell max @ 24 VDC (one communication every 5 sec 6820: Addressable fire alarm control panel International, Inc. with EOL <1K) 6820EVS: Addressable fire alarm control panel This document is not 5.5 mA (with LED latched on) with an emergency mass notification system. intended to be used for LED Current: 5.5 mA (with LED latched on) 6808: Addressable fire alarm control panel installation purposes. We End -of -Line Resistance: 47KCI 6700: Addressable fire alarm control panel tryto keep our product information up -to Initiating Device Circuit Wiring Resistance: 1,500 5700: Addressable fire alarm control panel date and accurate. We 0max 5808: Addressable fire alarm control panel cannotcoverall specific SLC Loop Resistance:40 Q max. 5820XL: Addressable fire alarm control panel applications or anticipate all requirements. All ENVIRONMENTAL 5820XL-EVS: Addressable fire alarm control panel specifications are subject with an emergency mass notificationsystem g y to change without notice. Operating Temperature: 32°F —120°F (01C — 49°C) For Technical Support, Humidity: 10%— 93% non -condensing caIt 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products byvisiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford, CT 06472 Doc 3501311 Rev G 1 11/17 SILENT' 800-328-0103 © 2017 Honeywell International Inc. ®HIVIGHT