FIELD INSPECTIONCUSTOM DESIGN & ENGINEERING, INC STRUCTURAL ANALYSIS & DESIGN FIELD INSPECTION Date: March 16, 2021 Reference Project: 542 HOLLY DRIVE, EDMONDS Reference Permit #: BLD2020-1299 We performed an on -site visit to the above referenced address to inspect a new foundation (un-poured at the time of the visit). The bottom of footing is not 18" below undisturbed soil. We find the installation structural acceptable based on the following- 1 . The footing is 18" wide x 8" thick and its only supporting one floor and a wood framed roof. 2. Bearing as noted (in the field) is 1500 psf (minimum). 3. There are two (2) #4 continuous bars. 4. The back -fill inside the addition will be less than four (4) feet M R and the back -fill on the outer surface will be approximately 18 ti o u inches. 'PO 35923 RAL L� SIONAL March 16, 2021 11006 60T" AVE WEST - MUKILTEO WA 98275 PHONE (425) 343-7517 - FAX (425) 493-8388