U t r H 1.1.1 PROJECT NOTES: 1.1.2 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE (CEC) ARTICLE 690, ALL MANUFACTURERS'S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S (AHJ) APPLICABLE CODES. 1.1.3 THE UTILITY INTERCONCECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 1.1.4 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY -INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY CEC 690.4: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): ILL 1703 OR ILL 1741 ACCESSORY. 1.1.8 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO CEC 690.7. 1.1.9 ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [CEC 110.3]. 1.1.10 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE CEC AND AHJ. 1.2.1 SCOPE OF WORK: 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID -TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF -MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 1.3.1 WORK INCLUDES: 1.3.2 PV ROOF ATTACHMENTS - SNAP-N-RACK ULTRA RAIL COMP KIT 1.3.3 PV RACKING SYSTEM INSTALLATION - SNAPNRACK UR-40 1.3.4 PV MODULE AND INVERTER INSTALLATION - MISSION SOLAR MSE320SR8T I GENERAC PWRCELL APKE00014 1.3.5 PV EQUIPMENT GROUNDING 1.3.6 PV SYSTEM WIRING TO A ROOF -MOUNTED JUNCTION BOX 1.3.7 PV LOAD CENTERS (IF INCLUDED) 1.3.8 PV METERING/MONITORING (IF INCLUDED) 1.3.9 PV DISCONCECTS 1.3.10 PV FINAL COMMISSIONING 1.3.11 (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV 1.3.12 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE SCOPE OF WORK SYSTEM SIZE: STC: 8 X 320W = 2.560KW PTC: 8 X 294.2W = 2.354KW DC (8) MISSION SOLAR MSE320SR8T (1) GENERAC PWRCELL APKE00014 (1) PWRCELL BATTERY CABINET I W 6X BATTERY MODULE ATTACHMENT TYPE: SNAP-N-RACK ULTRA RAIL COMP KIT MSP UPGRADE: NO NEW PV SYSTEM: 2.560 kW MEYER RESIDENCE 932 DAYTON STREET, EDMONDS, WA 98020 ASSESSOR'S #: 00434206901300 AERIAL PHOTO 01 NOT TO SCALE DAYTON STREET MAPLE WAY PLAT MAP 02 NOT TO SCALE P N W E S r r PROJECT INFORMATION OWNER NAME: MELANIE MEYER PROJECT MANAGER NAME: PHONE: CONTRACTOR NAME: SWITCH ELECTRIC PHONE: (425) 629-0009 AUTHORITIES HAVING JURISDICTION BUILDING: LABOR AND INDUSTRIES ZONING: LABOR AND INDUSTRIES UTILITY: PUGET SOUND ENERGY INC - RESIDENTIAL DESIGN SPECIFICATIONS OCCUPANCY: 11 CONSTRUCTION: SINGLE-FAMILY ZONING: RESIDENTIAL GROUND SNOW LOAD: 15 PSF WIND EXPOSURE: B WIND SPEED: 110 MPH APPLICABLE CODES & STANDARDS BUILDING: IBC 2015, IRC 2015 ELECTRICAL: NEC 2017 FIRE: IFC 2015 n SWITCH C-LECTRIC HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC. NO.: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN:00434206901300 ENGINEER OF RECORD PAPER SIZE: 11" x 17" (ANSI B) COVER PAGE POWERED BY O GREENLANCER w .greenlanceccom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS T-001.00 H (SHEET 1) A m b 2.1.1 SITE NOTES: 2.4.9 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH STORAGE BATTERIES. 2.4.10 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED 2.5.1 ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION CEC 110.26. 2.5.2 2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S 2.5.3 INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. 2.5.4 2.2.1 EQUIPMENT LOCATIONS 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY CEC 110.26. 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY CEC 690.31 (A),(C) AND CEC TABLES 310.15 (13)(2)(A) AND 310.15 (13)(3)(C). 2.5.5 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO CEC 690.34. 2.2.4 ADDITIONAL AC DISCONCECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONCECT. 2.5.6 2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO CEC APPLICABLE CODES. 2 5 7 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 2 5 8 2.3.1 STRUCTURAL NOTES: 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO 2 6.1 CODE -COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A 2 6 2 DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER'S INSTRUCTIONS. 2.6.3 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF -PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL 2 6.4 REQUIREMENTS. 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED 2 6.5 CONTRACTOR. 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 2.4.1 GROUNDING NOTES: 2.4.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND 2.6.6 GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.4.3 PV SYSTEMS REQUIRE AN EQUIPMENT GROUNDING CONDUCTOR. ALL METAL 2.6.7 ELECTRICAL EQUIPMENT AND STRUCTURAL COMPONENTS BONDED TO GROUND, IN ACCORDANCE WITH 250.134 OR 250.136(A). ONLY THE DC CONDUCTORS ARE 2.6.8 UNGROUNDED. 2.4.4 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO CEC 690.43 AND MINIMUM CEC TABLE 250.122. 2.6.9 2.4.5 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURE CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 2.4.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN 2.7.1 MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE 2 7 2 NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 2.4.7 THE GROUNDING CONCECTION TO A MODULE SHALL BE ARRANGED SUCH THAT 2.7.3 THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO 2.7.4 ANOTHER MODULE. 2.4.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [CEC 250.1191 A 0n n U m t m THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC 690.47 AND CEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO CEC 250, CEC 690.47 AND AHJ. DC PV ARRAYS SHALL BE PROVIDED WITH DC GROUND -FAULT PROTECTION MEETING THE REQUIREMENTS OF 690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDS INTERCONCECTION NOTES: LOAD -SIDE INTERCONCECTION SHALL BE IN ACCORDANCE WITH [CEC 705.12 (B)] THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF BUSBAR RATING [CEC 705.12(B)(2)(3)]. THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [CEC 705.12(B)(2)(3)]. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO CEC 705.12 (B)(2)(3)(C). FEEDER TAP INTERCOCECTION (LOAD SIDE) ACCORDING TO CEC 705.12 (B)(2)(1) SUPPLY SIDE TAP INTERCONCECTION ACCORDING TO CEC 705.12 (A) WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH CEC 230.42 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [CEC 705.12 (B)(5)]. DISCONCECTION AND OVER -CURRENT PROTECTION NOTES: DISCONCECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONCECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS). DISCONCECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH. BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED. THEREFORE BOTH MUST OPEN WHERE A DISCONCECT IS REQUIRED, ACCORDING TO CEC 690.13. ISOLATING DEVICES OR EQUIPMENT DISCONCECTING MEANS SHALL BE INSTALLED IN CIRCUITS CONCECTED TO EQUIPMENT AT A LOCATION WITHIN THE EQUIPMENT, OR WITHIN SIGHT AND WITHIN 10 FT OF THE EQUIPMENT. AN EQUIPMENT DISCONCECTING MEANS SHALL BE PERMITTED TO BE REMOTE FROM THE EQUIPMENT WHERE THE EQUIPMENT DISCONCECTING MEANS CAN BE REMOTELY OPERATED FROM WITHIN 10 FT OF THE EQUIPMENT, ACCORDING TO CEC 690.15 (A). PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D) ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC 690.8, 690.9, AND 240. BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED, THEREFORE BOTH REQUIRE OVER -CURRENT PROTECTION, ACCORDING TO CEC 240.21. (SEE EXCEPTION IN CEC 690.9) IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC -FAULT CIRCUIT PROTECTION ACCORDING TO CEC 690.11 AND UL1699B. WIRING & CONDUIT NOTES: ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP -SIZING. ALL CONDUCTORS SIZED ACCORDING TO CEC 690.8, CEC 690.7. EXPOSED PV SOURCE CIRCUITS AND OUTPUT CIRCUITS SHALL USE WIRE LISTED AND IDENTIFIED AS PHOTOVOLTAIC (PV) WIRE [690.31 (C)]. PV MODULES WIRE LEADS SHALL BE LISTED FOR USE ON PV ARRAYS, ACCORDING TO CEC 690.31 (A). 2.7.5 PV WIRE BLACK WIRE MAY BE FIELD -MARKED WHITE [CEC 200.6 (A)(6)]. 2.7.6 MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY. 2.7.7 ACCORDING TO CEC 200.7, UNGROUNDED SYSTEMS DC CONDUCTORS COLORED OR MARKED AS FOLLOWS: DC POSITIVE- RED, OR OTHER COLOR EXCLUDING WHITE, GREY AND GREEN DC NEGATIVE- BLACK, OR OTHER COLOR EXCLUDING WHITE, GREY AND GREEN 2.7.8 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE*, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY * IN 4-WIRE DELTA CONCECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [CEC 110.15]. SWITCH C-LECTRIC HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN: 00434206901300 ENGINEER OF RECORD PAPER SIZE: 11" x 17" (ANSI B) NOTES POWERED BY O GREENLANCER w .greenlanceccom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS G-001.00 (SHEET2) 4 h GENERAL NOTES RIFY ALL MEASUREMENTS :LOW MAY NOT BE ON THIS PAGE -- PROPERTY LINE MAPLE WAY SITE PLAN N 01 1116" = V-0" 0 8' 16' w E s R F F (; H c ITCH HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC. NO.: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN: 00434206901300 ENGINEER OF RECORD PAPER SIZE: 11"x 17" (ANSI B) SITE PLAN POWERED BY Q GREENLANCER —.greenlancer.com DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M REVISIONS A-101.00 (SHEET 3) U m t ■ Yi GENERAL NOTES L L 4 ELECTRICAL PLAN N 01 3132"m 1' 0 5'-4" 10'.8" W E S n n EXTERIOR PV EQUIPMENT (E) (1) METER (N) (1) AC DISCONNECT (N) (1) INVERTER INTERIOR PV EQUIPMENT (E) (1) MAIN ELECTRICAL PANEL (N) (1) PROTECTED LOADS PANEL (N) (1) BATTERY CABINET v AZIMUTH: 180 DEGREES 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE OMODULE STRINGING FIRE CLEARANCE 39.68" MODULE: MISSION SOLAR 65.98" MSE320SR8T 320 WATTS SWITCH C-LECTRIC HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN:00434206901300 ENGINEER OF RECORD PAPER SIZE: 11" x 17" (ANSI B) ELECTRICAL PLAN POWERED BY Q GREENLANCER w .greenlanceccom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M REVISIONS A-102.00 (SHEET 4) ■ Yi GENERAL NOTES L 4 n u SOLAR ATTACHMENT PLAN N J 3132" =1' 0 5'-4" 10'-8" J S v L ROOF MATERIAL IS ASPHALT SHINGLE FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE (SEE SHEET S-501 FOR MOUNTING DETAILS) 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ROOF TRUSSES 39.68" I I MODULE: MISSION SOLAR 65.98" MSE320SR8T 320 WATTS SWITCH ELECTRIC HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN:00434206901300 ENGINEER OF RECORD PAPER SIZE:11" x 17" (ANSI B) SOLAR ATTACHMENT PLAN POWERED BY O GREENLANCER w .greenlanceccom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M REVISIONS A-103.00 (SHEET 5) F-,,] RACKING DETAIL (TRANSVERSE) 0 NOT TO SCALE 10 O RACKING DETAIL(TOP) D3 NOT TO SCALE DETAIL TRANSVERSE NOT TO SCALE u zo RACKING DETAIL (LONGITUDINAL' NOT TO SCALE w 0 0 0 0 0 DETAIL(LONGITUDINAL)- D5 NOT TO SCALE n n GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS O SHEET KEYNOTES 1. ROOF MATERIAL: ASPHALT SHINGLE 2. ROOF STRUCTURE: TRUSS 3. ATTACHMENT TYPE: SNAP N RACK ULTRA RAIL COMP KIT 4. MODULE MANUFACTURER: MISSION SOLAR 5. MODULE MODEL: MSE320SR8T 6. MODULE LENGTH: 65.98 IN. 7. MODULE WIDTH: 39.68 IN.. 8. MODULE WEIGHT: 44 LBS. 9. SEE SHEET A-103 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: 18" FROM RIDGE, 36" FROM EDGE 11. TRUSS SPACING: 24 IN. O.C. 12. TRUSS SIZE: 2X4 NOMINAL 13. LAG BOLT DIAMETER: 5/16" IN. 14. LAG BOLT EMBEDMENT: 2-1/2 IN. 15. TOTAL # OF ATTACHMENTS: 16 16. TOTAL AREA: 145.45 SQ. FT. 17. TOTAL WEIGHT: 381.52 LBS. 18. WEIGHT PER ATTACHMENT: 23.85 LBS. 19. DISTRIBUTED LOAD: 2.62 PSF 20. MAX. HORIZONTAL STANDOFF: 48 IN. 21. MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 33 IN. 22. STANDOFF STAGGERING: YES 23. RAIL MANUFACTURER (OR EQUIV.): SNAP N RACK 24. RAIL MODEL (OR EQUIVALENT): UR-40 RAIL 25. RAIL WEIGHT: 0.42 PLF. 26. MAX. TRUSS SPAN: N/A. 27. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. VL WITCI-1 CTRIC HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN:00434206901300 ENGINEER OF RECORD PAPER SIZE: 11" x 17" (ANSI B) ASSEMBLY DETAILS POWERED BY Q GREENLANCER w .grmnlanwr.com DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS S-501.00 (SHEET 6) u I L 4 CONDUCTOR AND CONDUIT SCHEDULE MELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT -CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125/0) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERMINAL 1 1 10 AWG PV WIRE, COPPER FREE AIR 2 N/A 6 AWG BARE, COPPER 1 (27.3 °C) 1 8A 10A 55A 55A 75°C 50A 2 1 10 AWG THWN-2, COPPER 0.5 DIA EMT 2 N/A 10 AWG THWN-2, COPPER 1 (27.3 °C) 1 8A 10A 40A 40A 75°C 35A 3 1 8 AWG THWN-2, COPPER 0.75" DIA EMT 2 N/A 8 AWG THWN-2, COPPER 1 (27.3 °C) 1 32A 40A 55A 55A 75°C 50A 4 1 8 AWG THWN-2, COPPER 0.75" DIA EMT 2 40A 8 AWG THWN-2, COPPER 1 (27.3 °C) 1 32A 40A 55A 55A 75°C 50A 5 1 10 AWG THWN-2, COPPER 0.75" DIA EMT 2 30A 10 AWG THWN-2, COPPER 1 (27.3 °C) 1 30A 40A 40A 75°C 35A 6 1 6 AWG THWN-2, COPPER 0.75" DIA EMT 2 50A 60 AWG THWN-2, COPPER 1 (27.3 °C) 1 50A 75A 75A 75°C 65A OMODULE STRINGING SYSTEM EQUIPPED WITH RAPID SHUTDOWN DISCONNECT PER NEC 690.12 SYSTEM COMPLIANT WITH NEC 690.13 PV MODULES SOLAR OPTIMIZERS MISSION SOLAR GENERAC MSE320SR8T PV LINK S2502 320W RAPID SHUTDOWN DISCONNECTS GENERAC SNAPRS RS801 1 2 O 8 ---- P + + + L (N) GENERAC BATTERY CABINET W/ (6) 3.00 KW PWRCELL BATTERY MODULES 5 I (N) (1) INVERTER GENERAC PWRCELL APKE00014 I OLAR w 0 Of Lu 30A +a 0 a U of 30A z w cD 30A [��30A 6 I 50A q G TO UTILITY GRID (UG) L2--- -N —L1 (E) JTILITY METER GROUND ROD (E) GROUNDING AC DISCONNECT (E) MAIN N G ELECTRODE 60A 200A I I N I I w1 4 (N) TO (E) ® 40A/2P LOADS L2 G L1 _ MAIN SERVICE PANEL 240/120 V 10, 3W EQUIPMENT LEFT EQUIPMENT RIGHT MAIN BUSS: 200A LINE IS (N) NEW LINE IS (E) EXISTING MAX BREAKER SIZE: UNLESS OTHERWISE (200 A x 1.2) - 200 A = 40 A NOTED. TO (E) LOADS (N)PROTECTED LOADS PANEL 240/120 V 10, 3W MAIN BUSS: 100A r C ITCH HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN:00434206901300 ENGINEER OF RECORD PAPER SIZE:11" x 17" (ANSI B) LINE DIAGRAM POWERED BY O GREENLANCER w .greenlanceccom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS E-601.00 (SHEET 7) A B C D E F G H SYSTEM SUMMARY 2 ASHRAE EXTREME LOW -9.6°C (14.7°F), SOURCE: SNOHOMISH CO (47.91 °;-122.28°) ASHRAE 2% HIGH 27.3°C (81.1 °F), SOURCE: SNOHOMISH CO (47.91 °; -122 28°) I 5 i NOMINAL STRING VOLTAGE 380V ARRAY OPERATING CURRENT 0.84A ARRAY STC POWER 2,560W ARRAY PTC POWER 2,354W MAX AC CURRENT 32A MAX AC POWER 7,600W MODULES INVERTER #1 REF. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING STRING #1 PM1-8 8 MISSION SOLAR MSE320SR8T 320W 294.2W 10.028A 9.351A 40.8V 34.22V-0.114V/°C (-0.28%/°C) 20A POWERBOX MAX OUTPUT CURRENT 8A OPTIMIZERS IN SERIES 1 POWER OPTIMIZERS MODULES INVERTER #1 REF. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING STRING #1 PM1-8 8 MISSION SOLAR MSE320SR8T 320W 294.2W 10.028A 9.351A 40.8V 34.22V-0.114V/°C (-0.28%/°C) 20A POWERBOX MAX OUTPUT CURRENT 8A OPTIMIZERS IN SERIES 1 POWER OPTIMIZERS POWER OPTIMIZERS REF. QTY. MODEL RATED INPUT POWER MAX OUTPUT CURRENT MAX INPUT ISC MAX DC VOLTAGE WEIGHTED EFFICIENCY P01-1 1 GENERAC PV LINK S2502 2500W 8A 18A 420V 99.0% INVERTERS REF. QTY. MAKE AND MODEL AC GROUND OCPD RATED MAX OUTPUT MAX INPUT MAX INPUT CEC WEIGHTED DISCONNECTS OCPDS REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE REF. QTY. RATED CURRENT MAX VOLTAGE SW1 1 SQUARE D DU222RB OR EQUIV, 60A 240VAC CB1 1 40A 240VAC SWITCH ELECTRIC HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN: 00434206901300 ENGINEER OF RECORD PAPER SIZE:11" x 17" (ANSI B) DESIGN TABLES POWERED BY O GREENLANCER �.greenlanceccom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: OCPDS REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE REF. QTY. RATED CURRENT MAX VOLTAGE SW1 1 SQUARE D DU222RB OR EQUIV, 60A 240VAC CB1 1 40A 240VAC SWITCH ELECTRIC HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN: 00434206901300 ENGINEER OF RECORD PAPER SIZE:11" x 17" (ANSI B) DESIGN TABLES POWERED BY O GREENLANCER �.greenlanceccom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: SWITCH ELECTRIC HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN: 00434206901300 ENGINEER OF RECORD PAPER SIZE:11" x 17" (ANSI B) DESIGN TABLES POWERED BY O GREENLANCER �.greenlanceccom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS E-602.00 (SHEET 8) U t m LABELING NOTES 1.1 LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. 1.5 ALERTING WORDS TO BE COLOR CODED. "DANGER" WILL HAVE RED BACKGROUND; "WARNING" WILL HAVE ORANGE BACKGROUND; "CAUTION" WILL HAVE YELLOW BACKGROUND. [ANSI Z5351 1.6 ALL SIGNAGE MUST BE PERMANENTLY ATTACHED AND BE WEATHER RESISTANT/SUNLIGHT RESISTANT AND CANNOT BE HAND-WRITTEN PER NEC 110.21(B) A WARNING l ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL AT EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (2" X 4"). [NEC 690.131. I Al WARNING I POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL 2 AT POINT OF INTERCONNECTION OVERCURRENT DEVICE (2" X 4"). [NEC 705.12(13)(2)(3)(B)]. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWICH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY LABEL 3 AT RAPID SHUTDOWN SYSTEM (3 3/4" X 51A"). [NEC 690.56(C)(1)(A)]. PHOTOVOLTAIC INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED POWER• EAST SIDE OF THE HOUSE DIRECTORY LABEL 4 PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING METHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERE MEANS IF NOT IN THE SAME LOCATION (5 3/4" X 1 1/8"). SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, [NEC 690.56(B)] OR FLOORS (5 3/4" X 1 1/8"). [NEC 690.31(G)] WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, A LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV REFLECTIVE SYSTEM DISCONNECTING MEANS. [IFC 605.11.1.11 PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN BATHROOMS [NEC 690.4(D),(E)] ■ A PI SHUT •WN PHOTOVOLTAIC SOLAR SWITCH FOR AC DISCONNECT SOLAR PV SYSTEM LABEL 9 AT EACH AC DISCONNECTING MEANS LABEL 5 (4" X 1 "). AT RAPID SHUTDOWN DISCONNECT SWITCH (5 1/4" X 2"). [NEC 690.13(B)]. [NEC 690.56(C)(3)]. PHOTOVOLTAIC SOLAR ACAUTION DC DISCONNECT LABEL 12 LABEL 10 AT EACH DISCONNECTING SOLAR ELECTRIC SYSTEM CONNECTED AT EACH DC DISCONNECTING MEANS MEANS (3"X X 4"). (4" X 1 "). [NEC 690.53]. LABEL 6 [NEC 690.13(B)]. AT UTILITY METER (5 3/4" X 1 1/8") [NEC 690.56(B)] . PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT = A NOMINAL OPERATING AC VOLTAGE E-247 V TRIPLE POWER SUPPLY 'A, WARNING LABEL 11 SOURCES: UTILITY GRID, SOLAR ELECTRIC AT POINT OF INTERCONNECTION, MARKED BATTERY AND PV SOLAR CIRCUIT BREAKER AT DISCONNECTING MEANS (4" X 2"). ELECTRIC SYSTEM IS BACKFED [NEC 690.54] LABEL 7 LABEL 8 AT POINT OF INTERCONNECTION AT POINT OF INTERCONNECTION (2 3/4" X 1 5/8") (2" X 1 "). [NEC 705.12(B)(3)] [NEC 705.12(B)(3)] !CAUTION! ° POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: FRONT \17 PV ARRAY ESS (INSIDE) MAIN DISTRIBUTION UTILITY DISCONNECT Z BACK O o S\VITCI-1 ELECTRIC HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN:00434206901300 ENGINEER OF RECORD PAPER SIZE: 11" x 17" (ANSI B) PLACARDS POWERED BY © GREENLANCER w ,greenlancer.com DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS E-603.00 (SHEET 9) 315-325W CLASS LEADING POWER OUTPUT 19.24% MAXIMUM EFFICIENCY 100% 90% 80% 70% 1 CERTIFIED RELIABILITY > Tested to UL1703 & IEC standards > PID resistant ADVANCED TECHNOLOGY > PERC and 5 busbar drive >19.2% module efficiency > Ideal for residential applications EXTREME WEATHER RESILIENCE > 5631 Pa front and back load (117 pso tested load to UL1703 BAA COMPLIANT FOR GOVERNMENT PROJECTS ) Buy American Act > American Recovery & Reinvestment Act FRAME -TO -FRAME WARRANTYT" 5 10 15 20 25 YEARS 0 ~ + 3 % CERTIFICATIONS IEC 61215 - IEC 61730 - IEC 61701 - UL 1703 - Salt mist POSITIVE POWER TOLERANCE c BL us CEC G - LISTED High -Power, American Quality Mission Solar Energy is headquartered in San Antonio, TX., with Please contact Mission Solar Energy if you have questions or concerns about certification of our products in your area. module production facilities on -site. We produce American quality solar *Standard 12-year product warranty extendable to 25 years with registration: modules ensuring the highest power output and reliability to our https://www.missionsolar.com/warranty/ customers. Our product line is well suited for residential, commercial and utility applications. Every Mission Solar Energy solar module is certified and surpasses industry standard regulations, proving excellent _ performance over the long-term. MISSION SOLAR www.missionsolar.com I Info@missionsolar.com Mlt Ill „,,' .. I( I . "... , ... ENERGY PERC 60 CLASS LEADING 315-325W Electrical Parameters at Standard Test Conditions (STC) Module Type MSE315SR8T MSE325SR8T IEC MSE320SR8T Power Output Pmax Wp 315 320 325 61215 - 61730 - 61701 - Salt mist Module Efficiency % 18.65 18.94 19.24 UL Tolerance 0-+3% 0-+3% 0-+3% UL 1703 listed Short -Circuit Current Isc A 9.997 10.028 10.060 Open Circuit Voltage Voc V 40.44 40.80 41.14 c L us O CEC Rated Current Imp A 9.253 9.351 9.387 tlsTEo Rated Voltage Vmp V 34.04 34.22 34.62 Fuse Rating 20 20 20 Normal Operating Cell Temperature (NOCT) 46.09°C (±2°C) Temperature Coefficient of Pmax-0.377% / °C Temperature Coefficient of Voc-0.280% / *C Temperature Coefficient of Isc 0.039% / 'C OPERATING • • Maximum System Voltage 1,000VdC Operating Temperature Range -40°C (-40°F) to +85°C (185°F) Maximum Series Fuse Rating 20A Fire Safety Classification Type 1, Class C Front & Back Load (UL standard) 5631 Pa (117 psf) Tested to UL1703 standard Hail Safety Impact Velocity 25mm at 23 m/s MECHANICAL DATA Solar Cells P-type mono -crystalline silicon (158.75mm) Cell Orientation 60 cells (6x10), 5 busbar Module Dimension 1676mm x 1008mm x 40mm (65.98 in. x 39.68 in. x 1.58 in.) Weight 20 kg (441b) Front Glass 3.2mm (0.126 in.) tempered, low -iron, anti -reflective coating Frame Anodized aluminum alloy Encapsulant Ethylene vinyl acetate (EVA) J-Box Protection class IP67 with 3 bypass -diodes Cables PV wire, 1m (39.37 in.), 4mm2 / 12 AWG Connector MC4 Compatible Container FT Pallets Panels 320 W 53' Double stack 36 936 299.52 kW 40' Double stack 28 728 232.96 kW Panels Weight Height Width Length Pallet 26 1,198lbs 42.45" 45.50" 67.00" Mission Solar Energy reserves the right to make specification changes without notice DOCUMENT #: C-SA2-MKTG-0018 REVISION #: R1 REVISION DATE: 1/13/2020 MSE320SR8T: 320WP, 60 CELL SOLAR MODULE CURRENT -VOLTAGE CURVE 12 Cells Temp. =25°C to Incident Irrd. = 1000 W/m2 Q 8 Incident Irrd. = 800 W/m2 v 6 Incident Irrd. = 600 W/m2 _ V Incident Irrd. =400 W/m2 a Incident Irrd. = 200 W/m2 2 0 0 10 10 30 40 Voltage M Current -voltage characteristics with dependence on irradiance and module temperature BASIC DESIGN (UNITS: mm) Front View 5 35 Dram Hoy ,noo 83e r6 GrauMi,g Hde 838 ,5 , ,Doe Back View 300 n Mounting Hole MISSION SOLAR �! ENERGY a Mission Solar Energy 1 8303 S. New Braunfels Ave., San Antonio, Texas 78235 info@missionsolar.com I www.missionsolar.com c ITO-I HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN: 00434206901300 ENGINEER OF RECORD PAPER SIZE: 11" x 17" (ANSI B) RESOURCE DOCUMENT POWERED BY O GREENLANCER �.greenlancercom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS r 0 - R-001.00 (SHEET 10) L a GEn 7.6kW 10, 11, Model: APKE Certification Model Reference: X7602, X11402 11 1 111 L%. 1\ Solar + storage is simple with the Generac PWRceIITM Inverter. This bi-directional, REbus'"-powered inverter offers a simple, efficient design for integrating smart batteries with solar. Ideal for self - supply, backup power, zero -export and energy cost management, the PWRcell Inverter is the industry's most feature -rich line of inverters, available in single-phase and three-phase models. FEATURES & BENEFITS • Single inverter for grid -tied solar with smart battery integration • Simplified system design: No autotransformer or battery inverter needed • User -selectable modes for backup power, self -supply, time -of -use and zero -export • Free system monitoring included via PWRview" Web Portal and Mobile App AC OUTPUT/GRID-TIE MODEL MODEL MODEL MODEL RATED AC POWER OUTPUT: 760OW 1140OW DC INPUT VOLTAGE RANGE: 360-420 VDC 360-420 VDC AC OUTPUT VOLTAGE: 120/240, 10 VAC 120/208. 30 VAC NOMINAL DC BUS VOLTAGE: 380 VDC 380 VDC AC FREQUENCY: 60 Hz 60 Hz MAX IMPORT CURRENT: 20A 30A MAXIMUM CONTINUOUS OUTPUT CURRENT: 32 A, RMS 32 A, RMS MAX INPUT CURRENT': 30A 30A GROUND -FAULT ISOLATION DETECTION: Included Included REVERSE -POLARITY PROTECTION: Yes Yes CHARGE BATTERY FROM AC: Yes Yes GROUND -FAULT ISOLATION DETECTION: Yes Yes THD(CURRENT): <2% <2% TRANSFORMERLESS, UNGROUNDED: Yes Yes TYPICAL NIGHTTIME POWER CONSUMPTION: <7W <7W TYPICAL NIGHTTIME POWER CONSUMPTION: <7W <7W MODELMODEL MODEL DC INPUT/ BATTERY •• AC OUTPUT/BACKUP APKE00014 APKE00013 APKE00014 APKE00013 RATED AC BACKUP POWER OUTPUT (ISLANDED): 8000W 8000W MAXIMUM CONTINUOUS POWER: 8000W 8000W MAXIMUM AC BACKUP POWER OUTPUT: 10000W 10000W INTERNAL DC DISTRIBUTION BREAKERS: 4X2p30A 4x2p30A AC BACKUP OUTPUT VOLTAGE: 120/240, 10 VAC 1201240, 10 VAC DC FUSES ON PLUS AND MINUS: 40 A 40 A AC FREQUENCY: 60 Hz 60 Hz 2-POLE DISCONNECTION: Yes Yes AC CIRCUIT BREAKER: 50 A 50 A THD(VOLTAGEY <2% <2%EFFICIENCY MODEL MODEL AUTOMATIC SWITCHOVER TIME: <1 Seconds <1 Seconds PEAK EFFICIENCY: 97% 98% TYPICAL NIGHTTIME POWER CONSUMPTION: 30W 30W CEC WEIGHTED EFFICIENCY: 96.50% 97.50% 'Inverter limits DC current import to AC power rating. Total DC current from multiple DC inputs may safely exceed this value up to Max. Input Current- The inverter safely limits the amount utilized 'Per input, four DC inputs total A n n n Sp e c i f i c a t i o n s ..........,............,.,......,,,....,, FEATURES MODES ISLANDING': Yes GRID SELL: SELF CONSUMPTION: Yes Yes i PRIORITIZED CHARGING FROM RENEWABLES: GRID SUPPORT - ZERO EXPORT: ADDITIONAL Yes Yes SUPPORTED COMMUNICATION INTERFACES: REbus'', CANbus, RS4854, Ethernet SYSTEM MONITORING: PWRview" Web Portal and Mobile App BACKUP LOADS DISCONNECT': Yes MANUAL INVERTER BYPASS SWITCH: Automatic WARRANTY: STANDARDS• 10 Years SAFETY: UL1741 SA, CSA 22.2 GRID CONNECTION STANDARDS: IEEE1547, Rule 21, Rule 14H, CSIP EMISSIONS: DIMENSIONS AND INSTALLATION SPECIFICATIONS ENCLOSURE KNOCKOUTS - CITY, SIZE - IN (MM): FCC Part 15 Class B 6 x Combo 3/4" x 1" (19 x 25.4) 7 x Combo 1/2" x 3/4" (12.7 x 19) DIMENSIONS L x W x H- IN (MM): 24.5" x 19.25" x 8" (622.3 x 488.9 x 203.2) WEIGHT - LB (KG): 62.7 (28.4) COOLING: Forced convection NOISE: <40 dBA OPERATING TEMPERATURE - FAHRENHEIT (CELSIUS): -4 to 122 "F (-20 to 50 "C)a PROTECTION RATING: INSTALLATION NEMA 3R BATTERY TYPES SUPPORTED: PWRcell' Battery MODULE STRING SIZE PER PV LINK OPTIMIZER: Varies, refer to PV Link Installation Manual MAXIMUM RECOMMENDED DC POWER FROM PV: 330 inverters offer islanding for 10 loads 4Modbus 5Reduced power at extreme temperatures 15kW Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com 1888-GENERAC (436-3722) A0000528185 REV C 02020 Generac Power Systems. All rights reserved. Specifications are subject to change without notice. GENERACA� C ITCH HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN: 00434206901300 ENGINEER OF RECORD PAPER SIZE:11" x 17" (ANSI B) RESOURCE DOCUMENT POWERED BY O GREENLANCER w .greenlancer.com DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS R-002.00 (SHEET11) GENERAL PV LinkTM 250OW MPPT Substring Optimizer Model #: S2502 (Ordering SKU: APKE00010) PV Link is the simple solar optimizer for quick installation and long-lasting performance. Connect PV modules to each PV Link to overcome shading and challenging roof lines. FEATURES & BENEFITS Fast, simple installation Lower failure risk than module -level optimizers 2017/2020 NEC rapid shutdown compliant with SnapRS`" Quick connections with MC4 connectors • Exports up to 250OW • Compatible with PWRcell'" Inverters Cost-effective solution for high-performance PV • Ground -fault protection PV Link / S2502 (� '..J GENERAL i Ijig s SINGLE -STRING PV ARRAY WITH SnapRS DEVICES Where PV module -level rapid shutdown is required (NEC 690.12), a SnapRS device (IRS) is installed to negative (-) lead of each PV module. GENERAL' PWIll �� � GENERAL 1 PV Link PWRceII Inverter c �- us us>£v Intertek RS Diagram is applicable for most 60 cell PV modules. Modules with higher cell count may require a different arrangement. Contact Generac for more details. ......,. Specifications RATED POWER*: 250OW PEAK EFFICIENCY: 99% MPPT VOLTAGE RANGE: 60-360 VMP MAX INPUT VOLTAGE: 420 VOC; max when cold MAX OUTPUT: 420 VOC NOMINAL OUTPUT (REbus"): 380 VDC MAX OUTPUT CURRENT (CONTINUOUS): 8 A MAX OUTPUT CURRENT (FAULT): 10 A MAX INPUT CURRENT (CONTINUOUS): 13 A @ 50°C,10 A @ 70°C MAX INPUT SHORT CIRCUIT CURRENT (ISC): 18 A STANDBY POWER: ' 1 W PROTECTIONS: Ground -fault, Arc -fault (Arc -fault Type 1 AFCI, Integrated), PVRSE MAX OPERATING TEMP: FAHRENHEIT (CELSIUS) 158 OF (70 °C) SYSTEM MONITORING: PWRview" Web Portal and Mobile App ENCLOSURE: Type 4X WEIGHT - LB (KG): 7.3 lb (3.3 kg) DIMENSIONS, LxWxH-IN(MM): 15.4" x 2" x 9.6" (391.2 x 50.8 x 243.8) COMPLIANCE: UL 1741, CSA 22.2 WARRANTY: 25 Years *PV Link can tolerate higher than rated power at its input if Max Input Voltage and Short Circuit Current specifications are not exceeded Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com 1888-GENERAC (436-3722) A0000528162 REV D ©2020 Generac Power Systems. All rights reserved. Specifications are subject to change without notice. GENERAC� C ITCH HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN: 00434206901300 ENGINEER OF RECORD PAPER SIZE: 11" x 17" (ANSI B) RESOURCE DOCUMENT POWERED BY O GREENLANCER u .greenlancercom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS R-003.00 H (SHEET 12) b L a GENERAC I SnapRS TM Inline Disconnect Switch Model #: RS801 (Ordering SKU: APKE00011) Generac SnapRS are a simple way to satisfy rapid shutdown compliance for solar + storage systems. Generac SnapRS are 2017/2020 NEC 690.12 compliant, don't require any extra hardware to mount, and need no pairing or fussy digital communications. FEATURES & BENEFITS • Fast, easy, and simple to install • One SnapRS device per PV module • Achieves PVRSS Compliance • Low cost, high efficiency solution SYSTEM DESIGN Snap a Generac SnapRS disconnect device (IRS) to the negative lead (-) of each module in the solar array for simple module -level rapid shutdown compliance. SnapRS devices isolate array voltage when a rapid shutdown is initiated at a PWRcell' Inverter. When rapid shutdown is initiated, SnapRS units isolate each PV module in the array, reducing array voltage to <80V in seconds. tGEN PWRZ PV Link PWRcell Inverter C US UsreO Intertek IRS Diagram is applicable for most 60 cell PV modules. Modules with higher cell count may require a different arrangement. Contact Generac for more details. Specifications SnapRS (APKE00011) ...............................,.....................................,...................,...,...........,...............,... PV MODULE MAX VOC: 75 V EFFICIENCY: 99.8%* MAX INPUT CURRENT: 13 A MAX TOTAL QTY IN SUBSTRING: 10 SHUTDOWN TIME: <10 Seconds ENCLOSURE RATING: NEMA 6P OPERATING TEMPERATURE- FAHRENHEIT (CELSIUS): -40to158•F (40 to 70 °C) CERTIFICATIONS: UL1741 PROTECTIONS: PVRSE WEIGHT - LB (KG): 0.17 (0.08) DIMENSIONS, L x W x H- IN (MM): 7" x 1" x 1" (177.8 x 25.4 x 25.4) WARRANTY: 25 Years *When used with a 50V panel Connect one SnapRS device to the negative lead of each PV module in the PV Link controlled array for complete PV Rapid shutdown performance S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com 1888-GENERAC (436-3722) A0000528183 REV D 02020 Generac Power Systems. All rights reserved. Specifications are subject to change without notice. GENE" A E m MnM n M r M r M 1 11 SWITCH ELECTRIC HOME ENERGY 1 CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN: 00434206901300 ENGINEER OF RECORD PAPER SIZE:11" x 17" (ANSI B) RESOURCE DOCUMENT POWERED BY Q GREENLANCER w .greenlanceccom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS R-004.00 (SHEET 13) FEATURES: Connect up to 2 PWRcells to a single PWRcell Inverter Plug -and -play with PWRcell Inverters and PV Links Residential and commercial application ready '10ELL GENERAC® Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com 1-888-GENERAC (1-888-436-3722) Specifications BATTERY MODULES: 3 4 5 6 USABLE ENERGY: 8.6 kWh 11.4 kWh 14.3 kWh 17.1 kWh POWER: RATED CONTINUOUS 3.4 kW 4.5 kW 5.6 kW 6.7 kW POWER: 60 MINUTES 4.2 kW 5.6 kW 7.0 kW 8.4 kW POWER: 2 MINUTES 5.0 kW 6.7 kW 8.4 kW 10.0 kW REBUS VOLTAGE: 360-420 VDC INPUT/OUTPUT MODULE VOLTAGE: 46.8 VDC ROUND-TRIP EFFICIENCY: 96.5% OPERATING TEMPERATURE: 41to113°F Fahrenheit (Celsius) (5 to 45 "C) RECOMMENDED AMBIENT 55to86"F TEMPERATURE: (13 to 30 °C) Fahrenheit (Celsius) MAXIMUM INSTALLATION 9834(3000) ALTITUDE: ft (m) DIMENSIONS L x W x H: in (mm) 68" x 22" x 10" (1727 x 559 x 254) WEIGHT (ENCLOSURE): lb (kg) 115 (52) WEIGHT (INSTALLED): lb (kg) 280 (127) 335 (152) 390 (178) 445 (202) WARRANTY: LI-ION MODULES 10 Years, (22.6 MWh) 10 Years, (30.2 MWh) 10 Years, (37.8 MWh) 10 Years, (45.3 MWh) WARRANTY: ELECTRONICS 10 Years AND ENCLOSURE COMMUNICATION PROTOCOL: REbus DC Nanogrid" COMPLIANCE: UL 9540, UL1973, UL1642, CSA22.2 Specifications subject to change without notice UPGRADING PWRCELL Inside of the PWRcell battery, the PWRcell battery modules are stacked 2-deep on three levels, allowing for up to six modules to be connected in series. Upgrade an existing PWRcell battery by adding modules and a module spacer (APKE00008) if required PWRcell 9 and PWRcell 15 require a module spacer. Generac offers a convenient PWRcell Battery Upgrade Kit (APKE00009) to help replace lost or misplaced hardware. A PWRcell Battery Upgrade Kit may be purchased from your Generac distributor. Refer to the table to the right for material requirements related to upgrading PWRcell. GENERAC® UPGRADE MATERIAL REQUIREMENTS Ending Configuration 0 c U r 1N PWRCELL 17 PWRCELL 15 PWRCELL 12 PWRCELL 9 +3 x PWRCeII Mod +2 x PWRCeII Mod +1 x PWRCeII Mod + 2 x APKE00009' +1 x APKE00009' +1 x APKE00009' PWRCELL12 +2 x PWRCeII Mod +IxAPKE00009' +1 x PWRCeII Mod +1xAPKE00008 + 1 x PWRCeII Mod PWRCELL 15 +1xAPKE00009' 'APKE00009 (Upgrade kit) only required if original hardware is unavailable Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com 1-888-GENERAC (1-888-436-3722) APKE00007 REV B a DESCRIPTION: DRAWN BY: SNAPNRACK, UR-40 RAIL mwatkins 5ap.Nrack- REVISION: Solar Mounting Solutions PART NUMBER(S): A 595 MARKET STREET, 29TH FLOOR • SAN FRANCISCO, CA 94105 USA (• 232-02449, 232-02450, 232-02451 PHONE415) 580-6900 FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH L-C. UR-40 RAIL PROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR 232-02451 BLACK ALL DIMENSIONS IN INCHES 1.50 1.09 22 22 1.56 1.62 1.38 .06 .09 06 MATERIALS: 6000 SERIES ALUMINUM OPTIONS: DESIGN LOAD (LBS): N/A CLEAR / BLACK ANODIZED ULTIMATE LOAD (LBS): N/A MILL FINISH TORQUE SPECIFICATION: N/A LB -FT BUNDLES OF 144 CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 5.85 1 rz 1 n 1 0 n II c ITCH HOME ENERGY CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN: 00434206901300 ENGINEER OF RECORD PAPER SIZE: 11" x 17" (ANSI B) RESOURCE DOCUMENT POWERED BY Q GREENLANCER W .greenlanceLcom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS R-006.00 (SHEET 15) DESCRIPTION: DRAWN BY: - SmEN SNAPNRACK, ULTRA RAIL COMP KIT mwatkins Fad REVISION: Solar Mounting Solutions PART NUMBER(S): B 595 MARKET STREET, 29TH FLOOR SAN 1—M... - .1. USA PHONE (415) 5806900 • FAX (415) 580 M2 SEE BELOW F_. ON.11 oaUsE REaFs ao�� ow �.TME 1 O � O 2 m 2 3 O � O PARTS LIST ITEM QTY PART NUMBER DESCRIPTION 1 1 242-92266 SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS 2 1 242-01219, 242-01220 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK 3 1 232-01375, 232-01376 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER DESIGN LOAD (LBS): 405 UP, 788 DOWN, 236 SIDE ULTIMATE LOAD (LBS): 2006 UP, 4000 DOWN, 1070 SIDE TORQUE SPECIFICATION: 12 LB -FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.80 t r n DESCRIPTION: DRAWN BY: n SNAPNRACK, ULTRA RAIL COMP KIT mwatkins ���p�C�- REVISION: Solar Mounting Solutions PART NUMBER(S): B 595 MARKET STREET, 29TH FLOOR $AN FRA..M.. - -105 USA PHONE (415) 5806900 FAX (415) 580-6902 SEEBELOW REEPRNFFOOu�IT�ONOiNTN�S—N—OONFiDEN ANDPREOPRIEURY. E M-N CONSENT OFSUNRRNN SIN LLC. UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM 6.75 11.75 0.35 3.25 8.75 ALL DIMENSIONS IN INCHES 11050 y f 45 A m n mnm n m r m r m m II SWITCH ELECTRIC HOME ENERGY 1 CONTRACTOR SWITCH ELECTRIC PHONE: (425) 629-0009 ADDRESS: 7226139TH AVE NE LAKE STEVENS, WA 98258 LIC. NO.: SWITCEL8340M HIC, NO,: ELE. NO.: UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 2.560 kWp MEYER RESIDENCE 932 DAYTON STREET EDMONDS, WA 98020 APN: 00434206901300 ENGINEER OF RECORD PAPER SIZE:11" x 17" (ANSI B) RESOURCE DOCUMENT POWERED BY O GREENLANCER w .greenlanceLcom DATE: 03.23.2021 DESIGN BY: V.P. CHECKED BY: M.M. REVISIONS R-007.00 (SHEET 16)