BLD2021-0492_Manufacturer_Specifications_and_Installation_Instructions_4.7.2021_2.05.01_PM_2133017Job Name:
Tag# WrD�AIKIN
Submittal Data Sheet
FTXS12LVJU / RXS12LVJU
1-Ton Wall Mounted Heat Pump System
Complete warranty details available from your local dealer or at
www.daikincomfort.com. To receive the 12-Year Parts Limited
Warranty, online registration must be completed within 60 days of
installation. Online registration is not required in California or Quebec.
If product is installed in a commercial application, limited warranty
period is 5 years.
Indoor Specifications
Airflow Rate (cfm)
Cooling
Heating
H
M
H
M
403
307
438
335
L
SL
L
SL
205
155
240
212
Sound(dBA)
H/M/L/SL
45/37/29/23
45/39/29/26
Dimensions (H x W x D) (in)
1 11-5/8 x 31-1/2 x 8-7/16
Weight (Lbs)
122
Outdoor Specifications
Compressor
Hermetically Sealed Swing Type
Refrigerant
R-410A
Refrigerant Oil
PVE (FVC50K)
Airflow Rate (cfm)
Cooling
Heating
H
1,183
H
992
L
989
.11111161
L
840
Sound Power Level (dBA)
63
Dimensions (H x W x D) (in)
21-5/8 x 30-1/8 x 11-1/4
Weight (Lbs)
75
Efficiency
Cooling
Heating
SEER
23
HSPF
12.5
EER
12.8
COP
4.35
Performance
Cooling (Btu/hr)
Rated (Min/Max)
12,000 (4,800 / 12,000)
Sensible @ AHRI
9,250
Moisture Removal gal/h
.5
Operating Range
50°F —115°F
Rated Cooling Conditions: Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB
Heating (Btu/hr)
1:@ 47" Rated (Min/Max)
14,400 (4,400 / 14,400)
2: @ 17" Rated
9,200
3: @ 5° Max
6,430
Operating Range
5°F — 65°F
1: Rated Heating Conditions:
2: Rated Heating Conditions:
3: Rated Heating Conditions:
Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
Indoor: 70°F DB/60°F WB
Outdoor: 17°F DB/15°F WB
Indoor: 70°F DB/60°F WB
Outdoor: 5°F DB/5°F WB
Electrical
208/60/1
230/60/1
System MCA
8.75
8.75
System MFA
15
15
Compressor RLA
4.4
3.9
Outdoor fan motor FLA
.22
.22
Outdoor fan motor W
23
23
Indoor fan motor FLA
.15
.15
Indoor fan motor W
23
23
MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A)
RLA: Rated load amps (A) W: Fan motor rated output (W)
Piping
Liquid (in)
1/4
Gas (in)
3/8
Drain (in)
5/8
Max. Interunit Piping Length (ft)
65.6
Max. Interunit Height Difference (ft)
49.2
Chargeless (ft)
32.8
Additional Charge of Refrigerant (oz/ft)
.21
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Creation Date: June 2017 Page 1 of 4
0
m
m
O
.cn
J
N
U)
X
I�
H
THE MARK (-�) SHOWS PIPING DIRECTION
31-1/2 (800mm)
AIRFLOW (INDOOR)
I REAR I
LEFT RIGHT \ MOUNDTING PLATE/
8-9116 (217mm)
8-7116 (215mm) 1-15/16 (50mm) MIN
(SPACE FOR
MAINTENANCE)
FRONTGRILLE E NAME PLATE
FIXEDSCREWS Lo
E
(INSIDE) N TERMINAL BLOCK
WITH GROUND
`? TERMINAL
aI
BOTTOM + INTELLIGENT EYE SENSOR
LOUVERS SIGNAL RECEIVER
OPERATION LAMP
TIMER LAMP
INTELLIGENT EYE LAMP
INDOOR UNIT ON/OFF SWITCH
ROOM TEMP. THERMISTOR (INSIDE)
MODEL NAME PLATE
—SIGNAL TRANSMITTER BLADE ANGLES
2-5/16 (58mm) 11/16 (18mm) UP/DOWN
(AUTOMATIC)
COOLING, DRY HEATING FAN
a 0 0
E p O 15° 0 0
ro p p 30°
M 35° C '
� 30� 30°�
45°
22 55° 65° 65°
� 70° 80°
RIGHT/LEFT
(AUTOMATIC)
WIRELESS REMOTE CONTROLLER
(ARC452A21)
1-15/16 (50mm) MIN
REQUIRED SPACE (SPACE FOR MAINTENANCE)
GAS PIPE 03/8 (09.5mm) CUT -
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 13.3/4 (350mm))
LIQUID PIPE 61/4 (o6.4mm) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 15.3/4 (400mm)) 31 1/2
U
cc z
E02
M W 0
QO
Q
�a
DRAIN HOSE
(CONNECTING PART
O.D. 05/8 (016mm)
THE HOSE LENGTH OF OUTSIDE
THE UNIT IS APPROX. 18-5/16 (465mm))
--- - - - - - - - - - - - - - - - - - - - ---
I I
E I E E
I
I IM Lo
v I la N
c') I cy) T
I __ Ir
L-- - - - - - - - - - - - - - - -)
WALL HOLE FOR WALL HOLE
2-3/8 (60mm) EMBEDDED PIPING 02-9/-5/16 (06 (59.mm) HOLE
02-9/16 (065mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
C:3D074094A
O
N
HANDLE
m
m
O
.(n
E
J
N
v /
ry'/Xr'
MINIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE
=LESS THAN 47-1/4
DRAIN OUTLET 4-HOLES FOR ANCHOR BOLTS
(I.D 05/8 HOSE FOR CONNECTION) (M8 OR M10) Q
22-5/8 4-1/8 co
c\ 19-5/16 a 'A Lo
v a
cb
1-15/16 1-15/16
1-15/16 `O
7 �R
N M Q r
in
C')
11-1/4 5/16 1/2
30-1/8
BRAND NAME LABEL
2-1/2 TRAMINAL STRIP
MANUFACTURE'S WITH GROUND TRAMINAL OUTDOOR AIR THERMISTOR
LABEL
WIRING
INLET
CONDUIT MOUNTING PLATE / 7-11/16
SERVICE IN CASE OF REMOVING
PORT STOP VALVE COVER
LIQUID
STOP VALVE
((D1 /4C uT)
GAS STOP VALVE
(03/8 CuT)
a
Optional Accessories 7 DA1K,IN
Indoor Unit
Included
Part Number
Description
BRP072A43
Wireless Interface Adapter
BRC944B2-A08
Wired Remote Controller
BRCW90IA08
Wired Remote Controller Cord - 3m
DACA-BRCW901PIO
Remote Controller Cable, Plenum Rated, 10 ft
DACA-BRCW90IP25
Remote Controller Cable, Plenum Rated, 25 ft
DACA-TS1-I
Daikin ENVi Intelligent Thermostat Kit
DACA-CPI-1
Inline Condensate Pump (Fits inside all Daikin wall & floor mount units)
DACA-CP4-1
External Condensate Pump
KRP928BB2S
Interface Adaptor for DIII-NET
Included
Part Number
Description
Description
DACA-WB-3
Powder -Coated Wall -Mounted Bracket
KEH041A41
Drain Pan Heater RXS09 12LV
KKP937A4
Drain Plug for OD Unit
KPW937C4
Low Ambient Wind Baffle / Air Adjustment Grille (09/12 MBH)
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Creation Date: June 2017 Page 4 of 4