BLD2021-0511_Manufacturer_Specifications_and_Installation_Instructions_4.8.2021_5.25.54_PM_2136176FFDA /K/N Submittal Data Sheet 3.0-Ton Vertical Air Handling Unit FXTQ36PAVJU FEATURES • Reduced installation time with integrated Electronic Expansion Valve and Printed Circuit Boards • Improved application flexibility with the ability to mix and match with other Daikin indoor units on the same system • Wider application range with dual voltage 208-230V/1 ph/60Hz power supply • Reduced piping cost with smaller piping diameters • Improved user comfort with 2 selectable fan speeds (H and L) • Standard Limited Warranty: 10-year warranty on compressor and all parts BENEFITS • New fan "Auto" logic allowing the unit to be commissioned where the fan operation will cycle on and off with the load • Ideal replacement for traditional fan coils or vertical stack units • The ECM fan motor as standard contributes to the increase in energy efficiency, reduction in sound and increased ESP (up to 0.5" W.G.) MRY( 1 . C US USTEO Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Page 1 of 3 FFDA /K/N Submittal Data Sheet 3.0-Ton Vertical Air Handling Unit FXTQ36PAVJU Indoor Unit Model No. FXTQ36PAVJU Type: Ducted Rated Cooling Capacity (Btu/hr): 36,000 Sensible Capacity (Btu/hr): 23,370 Cooling Input Power (kW): 0.350 Rated Heating Capacity (Btu/hr): 40,000 Heatinq Input Power (kW): 0.35 DOOUNIT DETAILS - Power Supply (V/Hz/Ph): 208-230 / 60 / 1 Power Supply Connections: L1, L2, Ground Indoor Unit Name: Rated Cooling Conditions: Rated Heating Conditions: Rated Piping Length(ft): Rated Height Separation (ft): Airflow Rate (H/L) (CFM): Moisture Removal (Gal/hr): 3.0-Ton Vertical Air Handling Unit Indoor (°F DB/WB): 80 / 67 Ambient (°F DB/WB): 95 / 75 Indoor ff DB/WB): 70 / 70 Ambient (°F DBMB): 47 / 43 1,200/840 Min. Circuit Amps MCA (A): 3.30 Gas Pipe Connection (inch): 5/8 Max Overcurrent Protection (MOP) (A): Liquid Pipe Connection (inch): 3/8 Dimensions (HxWxD) (in): 53-1/4 x 22 x 24 Condensate Connection (inch): 3/4 Panel (HxWxD) (in): Sound Pressure () (dBA): Net Weight (lb): 145 Sound Power Level (dBA): Panel Weight (lb): Ext. Static Pressure (Rated/Max) (inWg): 0.50 / 0.50 Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Page 2 of 3 Submittal Data Sheet 3.0-Ton Vertical Air Handling Unit FXTQ36PAVJU DIMENSIONAL DRAWING (length: in.) Model A B C D E F G H 1 46- 17- 19- 14- 11- 17- 17- 12 18 type 22 10 314 1/2 1/2 1/2 15116 1/8 15116 24 • 30. 36 • 42 •48. 54 53- 24 20 22 12 14- 11- 19- 19- 3/4 1/2 15/16 5Jg 15/16 type (Top view) 24 or more .... (length: in.) • Ensure sufficlent space for the bottom of the product (H dimensions) so that a downward slope of 1/100 can be maintained for drain piping, as described for the Intake duct Installation and In "6. DRAIN PIPING WORK". Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Page 3 of 3 FFDA /K/N Submittal Data Sheet 3.0 Ton VRV-IVS Heat Pump RXTQ36TAVJU FEATURES • Variable Refrigerant Temperature (VRT) technology allows VRV IV S series to deliver improved efficiencies and year round comfort • Improved efficiencies with SEER values up to 18.0 and HSPF values up to 10.0 • Engineered with highly reliable Daikin Swing compressors • All inverter compressors to increase efficiency and avoid starting current rush • Can provide heating down to -4°F • Added safety with optional auto changeover to auxiliary heat • Easier installation with over 60% weight reduction compared to VRV III S BENEFITS • Single-phase technology enables installation in light commercial and residential applications • Broader diversity with up to 9 indoor units connectivity • Space saving compact design • Design flexibility with long piping lengths up to 984ft total and 49ft vertical separation between indoor units • Designed with reduced MOP to optimize installation costs • Backed by best in class 10-years Parts Limited Warranty and 10-years Replacement Compressor Limited Warranty* DA/K/N I YRYlt 9 NT ERI 1 C( T IV 1STEVS Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date: 11/29/2017 5:09:23 PM Page 1 of 3 FVDA /K/N Submittal Data Sheet 3.0 Ton VRV-IVS Heat Pump RXTQ36TAVJU Outdoor Unit Model No. Type: Rated Cooling Conditions: Rated Piping Length(ft): Rated Height Difference (ft): Rated Cooling Capacity (Btu/hr): Cooling Input Power (kW): EER (Non-Ducted/Ducted): SEER (Non-Ducted/Ducted): Max/Min Cooling Capacity (Btu/hr): RXTQ36TAVJU Heat Pump Indoor (°F DB/DB): 80 / 67 Ambient (°F DB/WB): 95 / 75 25 34,200 3.13 12.00 / 9.70 18.00 / 15.50 Power Supply (V/Hz/Ph): 208-230 / 60 / 1 Power Supply Connections: Min. Circuit Amps MCA (A): 16.5 Max Overcurrent Protection (MOP) (A): 25 Max Starting Current MSC(A): Rated Load Amps RLA(A): 15.3 Dimensions (HxWxD) (in): 39 x 37 x 12-5/8 Net Weight (lb): 172 Outdoor Unit Name: Rated Heating Conditions: 3.0 Ton VRV-IVS Heat Pump Indoor (°F DB/WB): 70 / 60 Ambient (°F DB/WB): 47 / 43 Rated Heating Capacity (Btu/hr): 37,000 Heating Input Power (kW): 3.12 Heating COP (Non-Ducted/Ducted): HSPF (Non-Ducted/Ducted): Max/Min Heating Capacity (Btu/hr): Compressor Stage Capacity Control Range (%): Airflow Rate (H) (CFM): Gas Pipe Connection (inch): Liquid Pipe Connection (inch) Sound Pressure (H) (dBA): Sound Power Level (dBA) 10.3 / 9.0 Inverter 14 - 100 2682 5/8 3/8 58 75 Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date: 11/29/2017 5:09:23 PM Page 2 of 3 FFDA /K/N Submittal Data Sheet 3.0 Ton VRV-IVS Heat Pump RXTQ36TAVJU Refrigerant Type: Holding Refrigerant Charge (lbs): Additional Charge (lb/ft): Pre -charge Piping (Length) (ft): Max. Pipe Length (Total) (ft): Max Height Separation (Ind to Ind ft): R-410A 6.4 820 DIMENSIONAL DRAWING �o 0 0 0 0 0 0 0 0 0 0 0 n Cooling Operation Range ff DB): Heating Operation Range (°F WB): Max. Pipe Length (Vertical) (ft): Cooling Range w/Baffle (°F DB): Heatinq Rance w/Baffle (°F WB): 23 - 122 -4 - 60 98 Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date: 11/29/2017 5:09:23 PM Page 3 of 3