Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ENG2021-0126 ROW PERMIT
OF WAY EUC PERMIT PERMIT NUMBER City of Edmonds AveRIGHT N, Edmonds WA 98020ENG2021-0126 www.cityofedmonds.gov Description: PUD REPLACING THREE BO POLES - EXPIRED PERMIT ENG2020-0342 ISSUED: 04/13/2021 Address: 22017 95TH PL W EDMONDS WA 98020-4518 EXPIRES: 10/13/2021 Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 00544200200101 NAME TYPE NAME ADDRESS PHONE APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 OWNER KLOS WILLI E 22017 95TH PL W, EDMONDS WA 98020-4518 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $0.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW J. MaJutgav 04/13/2021 RELEASED BY DATE Printed: Tuesday, April 13, 2021 11:39:09 AM 1 of 2 -KRWOF WAY EUC PERMIT City of • • • •:• •ENG2021-0126 www.cityofedmonds. ov/425.771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. Contractor/Owner shall be responsible for repair/replacement of all damage to utilities and/or DAMAGE TO FRONTAGE frontage improvements in city right of way per city standards that is caused by or occurs during the IMPROVEMENTS permitted project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQUIRED Maintain erosion & sediment control per city standards. Applicant on behalf of his or her spouse heirs assigns and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from HOLD HARMLESS any and all claims for damages of whatever nature, arising directly or indirectly from the issuance of this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. OTHER CONDITION TRANSFER OF UTILITIES, REMOVAL OF POLE, AND FINAL RESTORATION TO BE CONSISTENT WITH POLE ATTACHMENT AGREEMENT. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on SOUND OR NOISE weekdays and 10:00am to 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. UNDERGROUND UTILITY Call for locates of underground utilities prior to any excavation. LOCATES INSPECTION TYPE DATE RESULT NOTES 11P COMPLETE X-2 ENGINEERING FINAL** Printed: Tuesday, April 13, 2021 11:39:09 AM 2 of 2 of E DLIOL INC. 1890 PUD WORK ORDER 100046787 ROW PERMIT NO.: ENG 2021-0126 ISSUE DATE: 4/13/21 RIGHT-OF-WAY CONSTRUCTION PERMIT APPLICATION PROJECT NAME: Replace 3 Utility Poles CONTRACTOR: Snohomish PUD Mailing Address: PO Box 1107 State License #: City Business License #: CONTACT: Ben Ice RECEIVED Apr 07 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Phone #: 425 783 4355 Fax #: 425 267 6072 Email #: btice@snopud.com ❑ Liability Insurance ❑ Bonded ADDRESS OR INTERSECTION OF CONSTRUCTION: 22017 95th PI W, Edmonds ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: ❑ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only) ❑ Multi -Family ❑ Single Family ❑ Other 0 EUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit? ANY ASSOCIATED PERMITS? ❑ Yes 0 No BLD# ENG# DESCRIPTION OF PROPOSED WORK (Be Specific) : Replacing three old utility poles with new. Reapplication for expired permit ENG2020-0342. WAS STREET OVERLAYED WITHIN THE LAST FIVE (5) YEARS? YES NO Year: PAVEMENT CUT: ❑ Yes ❑■ No If yes, indicate size of cut: CONCRETE CUT: ❑ Yes ❑■ No If yes, indicate size of cut: x x RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF SF Alley 72 Hrs + LF X LF SF Parking 72 Hrs + LF X LF SF APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - NO EXCEPTIONS. Indemnity. The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the permit to be valid. SIGNATURE �- DATE 4/7/2021 Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE RECEIVED Apr 07 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ROAD W20-1 WORK = AHEAD O O ONE LANE W20-4 ROAD = AHEAD O W3-4 > • o W20-7A �� = O 0 O O 0 TRANSFER OF UTILITIES, O O REMOVAL OF POLE, AND O FINAL RESTORATION TO BE 3 CONSISTENT WITH POLE r J O ATTACHMENT AGREEMENT. O 3E O F- O m � O O w 0 FOR USE AT O a LOCATIONS: 0— A, B, & C 0 O • s W20-7A ENGINEERING DIVISION APPROVED AS NOTED 0 O <— W3-4 " ONE LANE ROAD W 2 0 — 4 I! 04/08/2021 AHEAD 0 0 s ROAD WORK W20-1 AHEAD Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way OWNER/CONTRACTOR IS RESPONSIBLE FOR per city standards that is caused or EROSION CONTROL AND DRAINAGE occurs during the permitted project. SNOHOMISH COUNTY G�CUM D) TRAFFIC CONTROL PLAN PUBLIC UTILITY DISTRICT NO 1 PROJECT REPLACE ONE UTILITY POLE LOCATION 22017 95TH PL W, EDMONDS ENGINEER BEN ICE DATE 5/24/2020 ORDER 100046787 PHONE 425 783 4355 o POLE TO BE Z REPS ASCED a a z a O � o 12 • POLE TO BE REPLACED z a a 2 S a POLE TO BE REPLACED 2 S Q POLE PLI # 1572 SET 45 CL 2 POLE (PW2045), 4' N SET DEPTH = 6.5' USE 5/8" GRVL BCKFLL, CMPCT IN 6" LETS FRAME 30 TANG ASSY (12F303) RMV 50 KVA OH XFMR UTC # ------------------- SER* HANG 37 KVA OH XFMR (12F601, BA21P) UTC # SER# XFR OH SVCS RMV EXIST STILL ARM INSTL 14'STLT ARM (10506) XFR STILT LUMINAIRE # SL-130161-A RMV EXIST SEC UG RISER INSTL 3" SEC RISER OU705) RUN 350 KCMIL TPX TO EXIST RED L= 50' © POLE PLI # 1571 SET 45 CL 2 POLE (PW2045), 2' S SET DEPTH = 6.5' USE 5/8" GRVL BCKFLL, CMPCT IN 6" LFTS FRAME 30 TANG ASSY (12F303) RMV 25 KVA OH XFMR UTC# ------------------- SER# HANG 25 KVA OH XFMR (12F601, BA21N) UTC # SER# ------------------- XFR OH SVCS RMV EXIST STILT ARM RMV EXIST SEC UG RISER INSTL 3" SEC RISER OU705) RUN 350 KCMIL TPX TO EXIST PED L= 110' S © POLE PLI # 1570 SET 45 CL 2 POLE (PW2045), 2' S SET DEPTH = 6.5' USE 5/8" GRVL BCKFLL, CMPCT IN 6" LFTS FRAME 30 TANG ASSY (12F303) RMV 50 KVA OH XFMR UTC #_ SER# ___ __ ___ HANG 37 KVA OH XFMR (12E601, BA21P) UTC # SER# XFR OH SVCS RMV EXIST STILT ARM INSTL 12'STLT ARM (10505) XFR STILT LUMINAIRE # SL-130176-A TRANSFER OF UTILITIES, REMOVAL OF POLE AND FINAL RESTORATION TO 7 BE CONSISTENT WITH POLE ATTACHMENT AGREEMENT. N NORTH g9nTN 7 QIAI PLAN VIEW 1" = 100' TO FIVE CORNERS TO FIVE CORNERS CKT# 12-1283 CKT# 12-1283 12-1335 12-1335 NO GO NO GO 132 41 50 10 132 37 00 25 40 25 a`40 50 a'10 37 WESTGATE WESTGATE CKT# 12-406 CKT# 12-406 BEFORE - -H SCHEMATIC NTS S NOHO MISH COUNTY p[oo PUBLIC Ui1L1iY OISiRICi NO 1 LOCATION 22017 95TH PL W.EDMONDS AREA LYNNWOOD POLE NO 1570, 1571, 1572 SE VAS 25 T 27 R 3 DATE 6/15/2020 ORDER 100046787 REASON FOR WORK REPLACE BO POLES ENGINEER BEN ICE OPERATION 0030 DRAFTER UGND NO APPROVED SCALE 1'' - 100' DATE PRINTED DATE WORK COMPLETED FOREMAN SUBSTATION WESTGATE FEES REQ'D CIRCUIT NO 12-406 PHASE 1 3 22 Cl YES ■ NO PRIMARY OVERHEAD ENGINEER BEN ICE ❑ RESIDENTIAL PHONE 425 783 4355 ❑ COMMERCIAL LEO# @3 S PRIMARY UNDERGROUND ❑ RESIDENTIAL ❑ COMMERCIAL BASIC FEE $ LEU# SECONDARY UNDERGROUND BASIC FEES_ @S----------- =$ UNDERGROUND PLAT BASIC FEES_ ENGINEERING 6 FT @ 3 = f PLAT CONSTRUCTION tFT @S = i STREET LIGHTING @ FT @ I = f CROSSINGS GFT@f = S WORK IN RIGHT OF WAY ❑ PRIMARY ❑ SECONADARY fFT@$ $ MISCELLANEOUS FEES VAULT $ PERMIT $ S S TOTAL DUE$ DATE PAID RECEIPT - NEW SVCE APPLICATION• NESC VIOLATIONS ■ NO ❑ YES (SEE NOTES) PERMITS (DATE GRANTED) ❑ TREE TRIM ❑ STATE ❑ COUNTY ■ CITY 9/30/2020 11 EASEMENTS ❑ REQUIRED E• ■ NOT REQUIRED DATE SENT TO R/W DATE APPROVED FOREIGN CONTACTS ■ JPN- ❑ JOINT TRENCH FRONTIER & CATV ❑ JOINT BORE FRONTIER & CATV ED POLE STENCILING FROM TO TAKE OFF POLE PRE-CONSTR REQUIREMENTS ❑ TREE TRIM ❑ PUD LOCATOR ❑ BACKHOE ❑ ❑ ONE CALL DATE No. STREET LIGHTING ■ YES ❑ NO M&R AS -BUILT GIs GIs QC M&R GIS Ph JOINT USE LOCATION MAP PAGE 454 H7 WORK ZONE I PUGET +Jr SOUND 524 196iH ` sT sw r uaN sT EDMONDS 104 I J L WOODWAY 0 VICINITY MAP LEGEND: O EXISTING POLE {�Q EXISTING POLE -TO BE REMOVED NEW POLE M NEW POLE TO REPLACE EXISTING POLE EXISTING DISTRIBUTION LINE V RE C E I� E D --__----_ NEW DISTRIBUTION LINE A p r 07 2021 EXISTING TRANSMISSION LINE — — —— NEW TRANSMISSION LINE CITY OF EDMONDS ------------------ NEW SECONDARY CONDUCTOR DEVELOPMENT SERVICES DEPARTMENT —— RIGHT-OF-WAY LINE PROPERTY LINE LINE TO BE REMOVED