2020-0238 MARKET PERGOLAof ED4 City of Edmonds
0
PLAN REVIEW COMMENTS
BUILDING DIVISION
Est. i s9° (425) 771-0220
DATE: 3/9/2020
TO: Applicant: FEED ME HOSPITALITY
Owner: THIRD AVENUE SOUTH PROPERTIES LLC
FROM: ERIC CARTER
RE: Plan Check: BLD2020-0238
Project Address: 508 MAIN ST
Project: MAR-KET - INSTALL PERGOLA W/ EXTERIOR HEAT TUBE
During a review of the plans by the Building Division for compliance with the applicable building
codes, it was found that the following information, clarifications, or changes are needed. Reviews by
other divisions, such as Planning, Engineering, or Fire, may result in additional comments that
require attention beyond the scope of this letter. Items that recur on this list appear in italics.
Please submit to a Permit Coordinator 2 sets of revised plans/documents, including a written
response letter that is in itemized letter format. Indicate where the `clouded' or otherwise highlighted
changes can be found on the revised plans. Upon receipt the re -submittal will be routed for review(s).
Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall.
Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays.
General:
The proposed plans include product information in regards to the polycarbonate sheeting
intended to cover the pergola structure. The polycarbonate sheeting will need to comply with
section 2606.4 of the 2015 IBC. This section requires the material to have an ignition
temperature of 650 degrees or greater when tested in accordance with ASTM D 1929. A smoke
developed index of not greater than 450 when tested under ASTM E 84 or UL723 or maximum
average smoke density not greater than 75 in accordance with ASTM D 2843. Additionally, the
proposed panels will comply with class CC 1 or CC2 combustibility rating? Please provide
manufactures documentation of the requirements listed.
Page 1 of 1
2. The proposed plans indicate with the installation of 75k BTU heater. Page 8 of the provided
heater documentation recommends that a 75k BTU heater be mounted I 18' above the floor.
By the provided plans, it is unclear how tall the roof structure will be. Please clarify and indicate
on the plans.
Thank you,
ERIC CARTER
City of Edmonds
(425) 771-0220
Page 2 of 2