FIR2020-0102+Fire_Sprinkler_Equipment_Specification_Sheets+11.24.2020_12.59.54_PMJa 0 Rel ble Specifically Listed for use in Multipurpose Systems that serve both domestic water and fire protection. Sprinkler Type Residential Flat Concealed Sprinkler listed for a minimum design density of .05 gpm/ft2 with "potable water". • Model RFC30 LL • Model RFC43 LL • Model RFC49 LL Features 1. National Sanitation Foundation (NSF) Cer- tified to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). 2. Very low water flow requirements. 3. Cover plate attachment (Plain or Perforated) with 1/2" (13mm) total adjustment 4. Thread-on/off or Push-on/off cover attach- ment option. 5. Smooth Aesthetic ceiling profile. 6. Available in white, brass, chrome and black plated or custom painted finishes. Patent Pending Listing & Approvals 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NSF Cerified to NSF/ANSI Standard 61 Annex G Product Description Model RFC30 LL, RFC43 LL and RFC49 LL Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers dif- fer from standard sprinklers primarily in their response time and water distribution patterns. Model RFC30 LL, RFC43 LL and RFC49 LL sprinklers discharge water in a hemi- spherical pattern below the sprinkler deflector. Residen- tial distribution patterns are higher and generally contain Bulletin 032 Rev. C Model RFC30 LL (SIN RA3211) Model RFC43 LL (SIN RA3212) Model RFC49 LL (SIN RA3216) Residential Flat Concealed Sprinklers Plain Cover Plate Perforated Cover Plate a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pat- tern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occu- pants. The RFC30 LL, RFC43 LL and RFC49 LL Sprinklers provide the best form of fire protection by combining an at- tractive appearance and (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The RFC30 LL, RFC43 LL and RFC49 LL are UL Listed and NSF Certified Residen- tial Sprinklers to be installed in the residential "potable" water applications of any occupancy in accordance with NFPA 13, 13R, & 13D and meets all applicable low lead standards, .25% or less. The cover plate adjustability of the RFC30 LL, RFC43 LL and RFC49 LL can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. CJ 0 W N 0 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application and Installation For use in fire sprinkler systems that also supply potable water to a plumbing fixture or fixtures. The RFC30 LL, RFC43 LL and RFC49 LL, for residential installa- tions, use a 165°F (74°C) fusible solder link in a tuning fork style sprin- kler frame with a drop -down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135°F (57°C) ordinary temperature clas- sification solder. When the ceiling temperature rises, the solder hold- ing the cover plate releases the cover allowing the deflector to drop into position and exposing the sprinkler inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop -down deflector is properly located below the ceiling. The residential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher well wetting. After a 21/8" inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. Installation Data: When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprin- kler frame. The wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PARTOF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC30 LL, RFC43 LLAND RFC49 LL CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135OF RATED COVERS. Note: A leak tight'/2' NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or im- pairment of the sprinklers. Cover assemblies provide up to'b" (13mm) of adjustment. Turn the cover clockwise until the flange is in contact with the ceiling. For the push-on/thread-off option, the cover assembly is pushed onto the cup and final adjustment is made by turning the cover clockwise un- til the skirt flange makes full contact with the ceiling. Cover removal Model (SIN) Thread Size Inch (mm) Nominal Orifice Inch (mm) Sprinkler Temp ating CCP Assembly Temp. Rating Max. Ambient Tem • K Factor Max. Pressure psi (bar) rF PC /F rc /F PC RFC 30 LL (RA3211) 1/2" (15) 21/64 (8,2) 165 74 135 57 100 38 3.0 (43.2) 175 (12) RFC 43 LL (RA3212) 1/2" (15) 3/E (10) 165 74 135 57 100 38 4.3(62) 175 (12) RFC 49 LL (RA3216) 1/2" (15) '/s (11) 165 74 135 57 100 38 4.9 (70.6) 175 (12) Note: 1 bar = 100 Kpa RFC 30 LL Max. Coverage Ordinary Temp. Rating Top of Deflector Minimum area Max. Spacing 165wF/74!'C to Ceiling Installation Spacing Flow Pressure Ft x Ft (m x m) Ft (m) (mm) Type Ft (m) GPM Vmin PSI(bar)Inch Concealed 12 x 12 (3,6 x 3,6) 12(3,6) 9(34,1) 9.0 (0,62) Smooth Ceilings'/2 to 1 (13 to 25.4) Beamed Ceilings per NFPA 13D, 13R or 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 10 (37,8) 11.0 (0,76) 13 installed in beams'/2 to 1 (13 to 25.4) For Ceiling types refer to NFPA 13, 13R or 13D RFC 43 LL Max. Coverage Ordinary Temp. Rating Top of Deflector Minimum area Max. Spacing 165r""' 4r'C to Ceiling Installation Spacing Flow Pressure Ft x Ft (m x m) Ft (m) (mm) Type Ft (m) GPM Vmin PSI(bar)Inch 12 x 12 (3,6 x 3,6) 12(3,6) 12(4,5) 7.8 (0,54) Smooth Ceilings'/2 to 1 (13 to 25.4) 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 9.1 (0,63) 16 x 16 (4,9 x 4,9) 16(4,9) 13 (49) 9.1 (0,63) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams'/2 to 1 (13 to 25.4) Concealed 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 18 (68) 17.5 (1,21) 20 x 20 (6,1 x 6,1) 20(6,1) 21 (79) 23.8 (1,64) For Ceiling types refer to NFPA 13, 13R or 13D RFC 49 LL Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating 165�'F/74r'C Top of Deflector to Ceiling (mm) Installation Type Minimum Spacing Ft (m) Flow GPM Vmin Pressure PSI(bar)Inch 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49) 7.0 (0,48) Smooth Ceilings'/2 to 1 (13 to 25.4) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams'/2 to 1 (13 to 25.4) Concealed 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 7.0 (0,48) 16 x 16 (4,9 x 4,9) 16(4,9) 13 (49) 7.0 (0,48) 18 x 18 5,5 x 5,5 18(5,5) 17 64,3 12.0 0,83 20x20(6,1 x6,1) 20(6,1) 20(75,73) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D 2. requires turning in the counter -clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or negative pressurization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impedi- ment Maintenance Model RFC3O LL, RFC43 LL and RFC49 LL Concealed Sprinklers should be inspected quarterly and the sprin- kler system maintained in accordance with NFPA25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate as- sembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Model RFC3O LL, RFC43 LL and RFC49 LL Residential Concealed Sprinkler Specification Sprinklers shall be clJLus Listed and NSF-61 Annex G certified low flow residential concealed sprinklers with drop - down deflector and adjustable flat cover plate engineered for a minimum design density of O.O5gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a'h" NPT thread. Thermal element shall consist of an approved black - painted beryllium -nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon -coated Belleville spring washer and machined brass cap water seal assem- bly containing no plastic parts. Sprinkler K-factors shall be a nominal 3.0 (43.2), 4.3 (62) and 4.9 (70.6), having a 3/8" Specify: 1. Sprinkler Model 2. Cover Plate Finish 3. Thread -On or Push -On Feature 1 '" x 112" REDUCING TEE OR ELBOW 6655 2 6' [58.42mm] DIA - CUP CEILING 2" [12.70mm] MAX. COVER ADJUSTMENT CCP COVER PLATE ASSEMBLY [ . mm] HOLE IN CEILING 2" [50.8mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION -' - [4.96mm] 3��"" [84.21mm] DIA. PLATE: 112" I`72.7mm7 ADJUSTMENT 006F601A and 7/16" orifice respectively. Temperature rating shall be Ordinary 165°F (74°C); cover plate temperature rating to be 135°F (57C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allow- ing a'/2" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop -down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory in- stalled inside the sprinkler cup to protect the drop -down sprinkler deflector from damage, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty — specify]. Resi- dential concealed sprinklers shall be Reliable Model RFC30 LL, SIN RA3211 (Bulletin 032), RFC43 LL, SIN RA3212 (Bul- letin 032) or Model RFC49 LL, SIN RA3216 (Bulletin 032). Ordering Information Cover Plate Finishes0) Standard Finishes Chrome White Paint Special Application Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi -gloss, unless specified otherwise. z> For the perforated style cover - plate, consult factory for avail- ability on these and other cus- tom finishes. 3. Uponof Uponor AquaPEX° White Submittal Information Revision C: Oct. 7, 2009 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved Bv: Technical Data Material: Crosslinked polyethylene PEX-a Engel Method; PEX 5006 Standard Grade Hydrostatic 200°F (93°C) at 80 psi Ratings (PPI): 180OF (82°C) at 100 psi 73.4°F (23°C) at 160 psi 1/2", 3/4", and 1" AquaPEX White only: 120OF (49°C) at 130 psi Linear Expansion Rate: 1.10"/10°F (120C)/100' Product Information and Application Use Uponor AquaPEX White is tubing used for hot and cold domestic potable water distribution, residential fire safety and radiant heating systems containing no ferrous corrodible components or where ferrous components are isolated from the tubina. ✓ Description Part Number I.D. (A) O.D. (B) 1/4" Uponor AquaPEX White, 100-ft. coil F1040250 0.241" 0.375" 3/8" Uponor AquaPEX White, 400-ft. coil F1090375 0.350" 0.500" 3/8" Uponor AquaPEX White, 1,000-ft. coil F1120375 0.350" 0.500" 1/2" Uponor AquaPEX White, 100-ft. coil* F1040500 0.475" 0.625" 1/2" Uponor AquaPEX White, 300-ft. coil* F1060500 0.475" 0.625" 1/2" Uponor AquaPEX White, 1,000-ft. coil* F1120500 0.475" 0.625" 5/8" Uponor AquaPEX White, 300-ft. coil F1060625 0.574" 0.750" 5/8" Uponor AquaPEX White, 1000-ft. coil F1120625 0.574" 0.750" 3/4" Uponor AquaPEX White, 100-ft. coil* F1040750 0.671" 0.875" 3/4" Uponor AquaPEX White, 300-ft. coil* F1060750 0.671" 0.875" 3/4" Uponor AquaPEX White, 500-ft. coil* F1100750 0.671" 0.875" 1" Uponor AquaPEX White, 100-ft. coil* F1041000 0.862" 1.125" 1" Uponor AquaPEX White, 300-ft. coil* F1061000 0.862" 1.125" 1" Uponor AquaPEX White, 500-ft. coil* F1101000 0.862" 1.125" 11/4" Uponor AquaPEX White, 100-ft. coil F1061250 1.054" 1.375" 11/4" Uponor AquaPEX White, 300-ft. coil F1021250 1.054" 1.375" 11/2" Uponor AquaPEX White, 100-ft. coil F1061500 1.244" 1.625" 11/2" Uponor AquaPEX White, 300-ft. coil F1021500 1.244" 1.625" 2" Uponor AquaPEX White, 100-ft. coil F1062000 1.629" 2.125" 2" Uponor AquaPEX White, 200-ft. coil F1052000 1.629" 2.125" 2" Uponor AquaPEX White, 300-ft. coil F1022000 1.629" 2.125" 3" Uponor AquaPEX White, 100-ft. coil F1063000 2.400" 3.125" 3" Uponor AquaPEX White, 350-ft. coil F1023000 2.400" 3.125" Installation Weight 4.0 lbs. 20.0 lbs. 44.0 lbs. 6.0 lbs. 18.0 lbs. 54.0 lbs. 28.0 lbs. 86.0 lbs. 10.0 lbs. 34.0 lbs. 54.0 lbs. 20.0 lbs. 56.0 lbs. 93.0 lbs. 34.0 lbs. 106.0 lbs. 44.0 lbs. 133.0 lbs. 68.2 lbs. 136.4 lbs. 204.6 lbs. 128.0 lbs. 442.0 lbs. Approved fittings are ProPEXs' fittings' for sizes W through 2" AquaPEX. Use WIPEXTM fittings for 3" AquaPEX. Refer to the AquaPEX Professional Plumbing Installation Handbook, AquaSAFETM Fire Safety Installation Guide or the Uponor Radiant Installation Handbook for details. Standards Codes Listings CSA B137.5; ASTM F876; ASTM IPC; UPC; *1/2% 3/4", 1" UL 1821; *ULC/ORD - C 199 P; IAPMO; CSA; HUD; WARNOCK HERSEY; NSF; F877; ASTM F1960; ASTM-E84; NSPC; NPC ITS; UL; ICC; ANSI/NSF 14- and 61-certified; CAN/ULC S102.2; U.S.: 3/4" diameter and ASTM-E119/UL 263 of Canada smaller; Canada: 1" diameter and smaller Related Applications PEX-a Plumbing Systems AquaSAFE Fire Safety Systems Contact Information Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 USA Phone: (800) 321-4739 Fax: (952) 891-2008 www.uponor-usa.com Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA Phone: (888) 994-7726 Fax: (800) 638-9517 www.uponor.ca IProPEX` is a registered trademark of Uponor, Inc. ProPEX"is a trademark of Uponor Ltd. ProPEX° Ring Submittal Information Revision A: March 17, 2009 Project Information Job Name: Uponof Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data - Material: PEX-a (Engel Method) Density 926 to 940 kg/m3 Degree of Crosslinking: 70% to 89% Product Information and Application Use Manufactured from PEX-a material, Uponor ProPEX° Rings are required to make a proper ProPEX connection.' Red print on the rings indicates hot lines. The 1/2" and 3/4" ProPEX rings with stop includes a leading edge chamfer and stop edge. ✓ Description ❑ ProPEX Ring, 3/8" ProPEX Ring with Stop, 1/2" (red print) ProPEX Ring with Stop, 1/2" ProPEX Ring, 5/8" ProPEX Ring with Stop, 3/4" ProPEX Ring, 1" ProPEX Ring, 11/4" PProPEX Ring, 11/2" ProPEX Ring, 2" Installation i Part Number Length i.d. o.d. Weight Q4690302 0.54" 0.49" 0.74" 0.005lbs. Q4690511 0.63" 0.63" 0.87" 0.006lbs. Q4690512 0.63" 0.63" 0.87" 0.006lbs. Q4680625 0.79" 0.75" 1.00" 0.008lbs. Q4690756 0.87" 0.88" 1.13" 0.012lbs. Q4681000 1.10" 1.13" 1.42" 0.020lbs. Q4681250 1.35" 1.38" 1.66" 0.030lbs. Q4681500 1.61" 1.63" 1.91" 0.040lbs. Q4682000 1.97" 2.14" 2.61" 0.133lbs. Square cut the Uponor ProPEX tubing. Remove excess material. Slide the ProPEX Ring over the end of the tubing (maximum 1/1 ' over -hang). When using the 1/2" ProPEX Ring with stop edge, slide the ring on (i.e., chamfered edge first) until the end of the tubing contacts the stop edge. Expand tubing and ring. Rotate tool a quarter turn after each expansion to prevent the formation of grooves. Remove the expansion tool and fully seat the tubing and ring against the shoulder of the fitting. You should make ProPEX connections at temperatures above 50F /-15°C. For more information, refer to the AquaPEX° Professional Plumbing Installation Handbook, AQUASAFE° Fire Safety Installation Guide or the Uponor Radiant Installation Handbook. Standards ASTM F1960 Codes IPC; UPC; NSPC; NPC of Canada Listings UL 1821 (1/2", 3/4" and 1"); ULC/ORD - C 199 P (1/2", 3/4" and 1"); HUD MR 1269; ICC ESR 1099; ANSI/NSF 14- and 61-certified Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. Radiant Heating and Cooling Systems 5925 148th Street West 2000 Argentia Rd., Plaza 1, Ste. 200 AQUASAFE Fire Safety Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1Wl CANADA Phone: (800) 321-4739 Phone: (888) 994-7726 Fax: (952) 891-2008 Fax: (800) 638-9517 www.uponor-usa.com www.uponor.ca 'ProPEX° is a registered trademark of Uponor, Inc. ProPEX­ is a trademark of Uponor Ltd. ProPEX° Engineered Submittal Information Revision D: June 8, 2012 Project Information Job Name: Polymer (EP) Tee Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Reoresentative: ADoroved Bv: Technical Data Material: UDEL° Polysulfone, 20% Glass -reinforced (1/2" to 1") Acudel° Modified Polyphenylsulfone (11/4" to 11/2") Radel° Polyphenylsulfone (2") Maximum Temperature (no pressure): 320°F (160°C) Maximum Working Temperature/Pressure: 210OF (99°C) at 150 psi (1,034 kPa) Product Information and Application Use The ProPEX° Engineered Polymer (EP) Tee makes diverting connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX8 or Wirsbo hePEXTM tubing.' Note: Branch size is listed last in the part descriptions. uponof Description Part Number A B Weight ❑ ProPEX EP Tee, MY' PEX x 1/2" PEX x 1/2" PEX Q4755050 2.50" 1.53" 0.02 lbs. ❑ ProPEX EP Tee, 3/4" PEX x 3/4" PEX x 3/4" PEX Q4757575 3.30" 1.94" 0.05 lbs. ❑ ProPEX EP Tee, 1" PEX x 1" PEX x 1" PEX Q4751010 4.10" 2.47" 0.07 lbs. ❑ ProPEX EP Tee, 11/4" PEX x 11/4" PEX x 11/4" PEX Q4751313 4.80" 3.22" 0.15 lbs. ❑ ProPEX EP Tee, 11/2" PEX x 11/2" PEX x 11/2" PEX Q4751515 5.80" 3.82" 0.25 lbs. ❑ ProPEX EP Tee, 2" PEX x 2" PEX x 2" PEX Q4752000 7.45" 4.79" 0.38 lbs. Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor AquaPEX° Professional Plumbing Installation Guide, AquaSAFET" Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F1960 Codes IPC; UPC; NSPC; NPC of Canada Listings IAPMO 3558; ANSI/NSF 14- and 61-certified; HUD MR 1269; ICC ESR 1099; UL 1821; U1_C/0RD-C199P Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. Hydronic Radiant Heating and Cooling Systems 5925 148th Street West 2000 Argentia Road, Plaza 1, Suite 200 Snow Melting Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Turf Conditioning Systems Phone: (800) 321-4739 Phone: (888) 994-7726 Permafrost Prevention Systems Fax: (952) 891-2008 Fax: (800) 638-9517 AquaSAFE Fire Safety Systems www.uponorpro.com www.uponorpro.com 1ProPEX® is a registered trademark of Uponor, Inc. ProPEXTM is a trademark of Uponor Ltd. ProPEX° Engineered Polymer (EP) Reducing Tee Submittal Information uponor Revision E: June 8, 2012 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: UDEL° Polysulfone, 20% Glass -reinforced (1/2 to 1") Acudel° Modified Polyphenylsulfone (11/4" to 11/2") p� Radel° R Polyphenylsulfone (2") Maximum Temperature (no pressure): 320°F (160°C) Max. Working Temperature/Pressure: 210OF (99°C) at 150 psi (1,034 kPa) Product Information and Application Use The ProPEX° Engineered Polymer (EP) Reducing Tee makes diverting connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX° or Wirsbo hePEXTM tubing.' Note: Branch size is listed last in the part descriptions. ✓ Description Part Number Length (A) Height (B) Weight ❑ ProPEX EP Reducing Tee, 1/2" PEX x 1/2" PEX x 3/a" PEX Q4755575 2.86" 1.76" 0.03 lbs. ❑ ProPEX EP Reducing Tee, 3/4" PEX x 1/2" PEX x 1/2" PEX Q4757555 3.10" 1.70" 0.04 lbs. ❑ ProPEX EP Reducing Tee, 3/4" PEX x 1/2" PEX x 3/a" PEX Q4757557 3.10" 1.94" 0.04 lbs. ❑ ProPEX EP Reducing Tee, 3/a" PEX x 3/4" PEX x 5/8" PEX Q4757563 3.30" 1.85" 0.05 lbs. ❑ ProPEX EP Reducing Tee, 3/4" PEX x 3/a" PEX x 1/2" PEX Q4757550 3.30" 1.70" 0.04 lbs. ❑ ProPEX EP Reducing Tee, 3/4" PEX x 3/a" PEX x 1" PEX Q4757710 3.64" 2.32" 0.08 lbs. ❑ ProPEX EP Reducing Tee, 1" PEX x 3/4" PEX x 3/a" PEX Q4751775 3.90" 2.24" 0.08 lbs. ❑ ProPEX EP Reducing Tee, 1" PEX x 3/4" PEX x 1" PEX Q4751751 3.90" 2.47" 0.08 lbs. ❑ ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 1/2" PEX Q4751150 4.10" 2.00" 0.08 lbs. ❑ ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 3/4" PEX Q4751175 4.10" 2.24" 0.09 lbs. ❑ ProPEX EP Reducing Tee, 11/4 PEX x 1" PEX x 3/4" PEX Q4751317 4.60" 2.73" 0.11 lbs. ❑ ProPEX EP Reducing Tee, 11/4" PEX x 1" PEX x 1" PEX Q4751311 4.60" 2.97" 0.12 lbs. ❑ ProPEX EP Reducing Tee, 11/4 PEX x 11/4" PEX x 3/4" PEX Q4751337 4.80" 2.73" 0.13 lbs. ❑ ProPEX EP Reducing Tee, 11/4 PEX x 11/4" PEX x 1" PEX Q4751331 4.80" 2.97" 0.14 lbs. ❑ ProPEX EP Reducing Tee, 11/2 PEX x 1" PEX x 3/4" PEX Q4751517 5.25" 3.06" 0.17 lbs. ❑ ProPEX EP Reducing Tee, 11/2 PEX x 1" PEX x 1" PEX Q4751511 5.25" 3.30" 0.18 lbs. ❑ ProPEX EP Reducing Tee, 11/2 PEX x 11/a" PEX x 3/4" PEX Q4751537 5.50" 2.65" 0.18 lbs. ❑ ProPEX EP Reducing Tee, 11/2 PEX x 11/4 PEX x 1" PEX Q4751531 5.50" 2.85" 0.19 lbs. ❑ ProPEX EP Reducing Tee, 11/2 PEX x 11/4 PEX x 11/4" PEX Q4751533 5.50" 3.15" 0.21 lbs. ❑ ProPEX EP Reducing Tee, 11/2 PEX x 11/2 PEX x 3/4" PEX Q4751557 5.80" 3.06" 0.20 lbs. ❑ ProPEX EP Reducing Tee, 11/2 PEX x 11/2 PEX x 1" PEX Q4751551 5.75" 3.30" 0.21 lbs. ❑ ProPEX EP Reducing Tee, 11/2 PEX x 11/2 PEX x 11/4" PEX Q4751553 5.80" 3.56" 0.22 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 3/4" PEX Q4752575 6.62" 3.30" 0.30 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 1" PEX Q4752051 6.50" 3.40" 0.30 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 11/4" PEX Q4752053 6.62" 3.80" 0.34 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 11/2" PEX Q4752055 6.62" 4.10" 0.35 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 2" PEX x 3/4" PEX Q4752275 6.93" 3.30" 0.34 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 2" PEX x 1" PEX Q4752210 6.93" 3.40" 0.36 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 2" PEX x 11/4" PEX Q4752213 6.62" 3.80" 0.37 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 2" PEX x 11/2" PEX Q4752215 7.13" 4.10" 0.44 lbs. Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor AquaPEX° Professional Plumbing Installation Guide, AquaSAFETI Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards Codes Listings CAN/CSA B137.5; ASTM F877; IPC; UPC; NSPC; NPC of Canada NSF U.P. CODE; ANSI/NSF 14- and 61-certified; HUD MR 1269; ASTM F1960 ICC ESR 1099; UL 1821 and ULC/0RD-C199P (except Q4757563) Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. Hydronic Radiant Heating and Cooling Systems 5925 148th Street West 2000 Argentia Rd., Plaza 1, Ste. 200 Snow and Ice Melting Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Turf Conditioning Systems Phone: (800) 321-4739 Phone: (888) 994-7726 Permafrost Protection Systems Fax: (952) 891-2008 Fax: (800) 638-9517 AquaSAFE Fire Safety Systems www.uponorpro.com www.uponorpro.com 1ProPEX° is a registered trademark of Uponor, Inc. ProPEXTM is a trademark of Uponor Ltd. ProPEX° Engineered Submittal Information Revision D: June 8, 2012 Project Information Job Name: Polymer (EP) Elbow Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: ADDroved Bv: Technical Data Material: Maximum Temperature (no pressure): Maximum Working Temperature/Pressure: UDEL° Polysulfone, 20% Glass -reinforced (1/2 to 1") Acudel° Modified Polyp henylsulfone (11/4" to 11/2") Radel° R Polyp henylsulfone (2") 320°F(160°C) 210OF (99°C) at 150 psi (1,034 kPa) Product Information and Application Use The ProPEX® Engineered Polymer (EP) Elbow makes 90-degree connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire safety and hydronic radiant heating and cooling systems. Each end of the elbow is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX° or Wirsbo hePEX'" tubing.' uponof Description Part A B Weight Number ❑ ProPEX EP Elbow,'/2" PEX x'/2" PEX Q4760500 1.30" 1.30" 0.02 lbs. ❑ ProPEX EP Elbow, 3/4" PEX x 3/4" PEX Q4760750 1.60" 1.60" 0.03 lbs. ❑ ProPEX EP Elbow, 1" PEX x 1" PEX Q4761000 2.10" 2.10" 0.07 lbs. ❑ ProPEX EP Elbow, 11/4" PEX x 11/4" PEX Q4761250 2.45" 2.45" 0.11 lbs. ❑ ProPEX EP Elbow, 11/2" PEX x 11/2" PEX Q4761500 2.77" 2.77" 0.18 lbs. ❑ ProPEX EP Elbow, 2" PEX x 2" PEX Q4762000 3.76" 3.76" 0.30 lbs. Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor AquaPEX° Professional Plumbing Installation Guide, AquaSAFE'" Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F1960 Codes IPC; UPC; NSPC; NPC of Canada Listings IAPMO 3558; ANSI/NSF 14- and 61-certified; HUD MR 1269; ICC ESR 1099; UL 1821; ULC/0RD-C199P Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. Hydronic Radiant Heating and Cooling Systems 5925 148th Street West 2000 Argentia Road, Plaza 1, Suite 200 Snow Melting Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Turf Conditioning Systems Phone: (800) 321-4739 Phone: (888) 994-7726 Permafrost Prevention Systems Fax: (952) 891-2008 Fax: (800) 638-9517 AquaSAFE Fire Safety Systems www.uponorpro.com www.uponorpro.com 1ProPEV is a registered trademark of Uponor, Inc. ProPEXTM is a trademark of Uponor Ltd. ProPEX° Fire Sprinkler Adapter Submittal Information Revision B: March 17, 2009 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: 300 Series Stainless Steel Product Information and Application Use Use the ProPEX° Fire Sprinkler Adapter in conjunction with the appropriate sprinkler to provide a multi -purpose residential fire sprinkler system'. For residential applications, the system is installed with the cold -potable portion of the Uponor plumbing system. Make connections with Uponor ProPEX fittings. These fittings are designed for use only with 3/4" or 1" AquaPEX° White tubing in the Uponor AQUASAFE° Looped System. uponof ✓ Description Part A B C D E Weight Number ProPEX Fire Sprinkler Adapter, 3/4" PEX x 1/2" FNPT Q7517550 0.75" 1.88" 2.50" 1.82" 1.41" 0.268 lbs. ProPEX Fire Sprinkler Adapter, 1" PEX x 1/2" FNPT Q7511050 0.75" 1.88" 2.50" 2.06" 1.54" 0.408 lbs. Installation Use appropriate ProPEX Ring for connecting the tubing. Refer to the AquaPEX Installation Handbook or the Uponor AQUASAFE° Installation Guide for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F 1960 Codes IPC; UPC; NSPC; IRC; IMC; NPC of Canada Listings ANSI/NSF 14- and 61-certified; U.P. Code; ICC ESR 1099; HUD MR 1269; UL 1821; ULC/ORD - C 199 P Related Applications PEX-a Plumbing Systems AQUASAFE Fire Safety Systems Contact Information Uponor, Inc. 5925 1481h Street West Apple Valley, MN 55124 USA Phone: (800) 321-4739 Fax: (952) 891-2008 www.uponor-usa.com Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA Phone: (888) 994-7726 Fax: (800) 638-9517 www.uponor.ca 'ProPEX° is a registered trademark of Uponor, Inc. ProPEXTM is a trademark of Uponor Ltd. The Design Criteria for Sloped & Sloped Beamed Ceilings in NFPA 13D One and Two Family Dwellings & Manufactured Homes Has Changed. In L U2 L L2 A�G D LISTED AREA OF COVERAGE CORRESPONDS TO CEILING SLOP L = THE MAXIMUM LISTED SPRINKLER SPACING, LENGTH (10'-0'MAXIMUM) ("'MINIMUM . L2 = ONE HALF THE MAXIMUM LISTED SPRINKLER SPACING (5'4'MAXIMUR (1'4'MINIMUM W = THE MAXIMUM LISTED SPRINKLER SPACING.VADTH (10'-0 . A =0'4'MAXIMUM. 8 •RANGE:912 (9A1ee18M2 (50.21 C=8'-0"MINIMUM. G 81,VL A mucoe A Tentative Interim Amendment (TIA No.1028R) to NFPA 13D for 2010 has been issued by the NFPA Standards Council. Testing supported by The Fire Protection Research Foundation indicates that residential sprinklers listed for applications with smooth, flat ceilings can meet the stated purpose in NFPA 13D standards when installed on a sloped or sloped and beamed ceiling. Sloped and Sloped/Beamed Ceilings, under certain conditions, can now be protected with 7 "'" °" residential sprinklers based upon a maximum two (2) sprinkler demand that has the same flow rate as the sprinklers smooth, flat ceiling listing. The TIA No.1028R revises NFPA 13D - 2010 edition sections 8.1.2, 8.1.3, A.8.1.2, and A.8.1.3. Please read and adhere to these sections for the complete new design criteria. A brief recap: The sprinklers in the design area shall be all of the sprinklers in a compartment, up to a maximum of two, which require the greatest demand for: • Smooth, flat ceilings to a maximum 24 feet in height. • Smooth, ceilings (with no beams) sloped up to 8/12 and a maximum ceiling height of 24' above the floor. • A ceiling with beams up to 14" deep sloped up to 8/12 and a maximum ceiling height of 24' above the floor. Pendent sprinklers shall be installed under the beams and the compartment cannot exceed 600 square feet. • A ceiling with beams of any depth sloped up to 8/12 and a maximum ceiling height of 24' above the floor. Sidewall or pendent sprinklers shall be installed in each pocket formed by the beams and the compartment cannot exceed 600 square feet. Ail Reliable residential sprinklers can be used for these applications bas4 pressure as listed for smooth and flat ceilings. {See Bulletins: 135, 006, This TIA is for 13D applications only. Changes to 13R will be in the 2013 Edition. Our special 10' x 10' spacing listings for sloped ceilings are still advantageous for 13R installations. (See Table 9, Bulletin 035). For any questions, please contact Technical Services at 1-800-55-RASCO. The Reliable Automatic Sprinkler Co., Inc. • Manufacturer & Distributor of Fire Protection Equipment wwwreliablesprinklercom • 1.800.431.1588